Owners Manual

17
FAQ AND TROUBLESHOOTING
CLEANING THE UNIT
•The Unit is dirty and needs to
be cleaned
•With EXTREME care use ONLY diluted alcohol
and a very soft 100% cotton cloth to sweep
dust and stains out.
•Any acid or not extremely soft cloth will
irreversibly damage the amplifier fine aesthetic.
•Do not use any alcohol to clean the unit
anodised label, or printed parts. Only dry cloth
is allowed.
SPEAKER HUMMING
PROBLEMS
OUT of PHASE
SOME DRIVERS DO NOT
WORK
•The unit is correctly coupled with
the Ground on DC.
The sound does not
have a proper focus
even when well
positioned.
The speakers hum
when the amplifier is
connected to the
System.
The speaker terminals (negative/
positive poles) are
inverted in some way on the amp or
on the speaker.
The bridges are not well
connected to the speaker terminal
(Binding Posts).
•The amplifier does not play music.
•Turn Off the amplifier first and then
rewire the speaker terminals correctly.
Connect the bridges properly.
•Connect them properly.
•Verify the connectivity and that the
music is played through a correct
source.
•The speaker cables are not well
connected to the speaker.
•The interconnect input and/or
output cables are not shielded.
•Be sure your area and personal
environment are well grounded.
Eventually isolate the ground Pin of the
power chord plug for verification.
•Be sure to always use shielded cables
for the amp connections.
ACTION DESCRIPTION HOW TO ADJUST IT
TROUBLESHOOTING
FAQ
SYMPTOM DESCRIPTION CAUSE REMEDY
For spare parts visit the official Gold Note store at:
www.akamaiaudio.it