4) Determine the location to mount the CMU on the wall. The CMU will normally be
mounted near the INDYME device. Review the following criteria to determine the
location.
The CMU should be mounted about eye level or above the cabinet.
The CMU should not be mounted over 1 foot higher than the top of the cabinet.
The CMU/MEU power supply brick must be inside the Catalina cabinet.
Determine a knock out hole on either side of the cabinet to open. The knock out
must be large enough to run the low voltage cable from the power supply, a
network patch cable and if needed the CMU/MEU power cable through the hole.
The diameter of the knock out hole is 1 1/8 inches.
The CMU should be 36 inches or less from the knock out hole on the Catalina
cabinet. If needed, the12 foot power extension cable from the Hot Spare Kit can
be used.
The provided network patch cable must reach the designated port on the switch.
INDYME Device
CMU