4) Mark the location of the Tx/ATA or Rx/ARA antennae on the floor directly below the
selected ceiling tile location or the roof iron.
Use the assigned antenna number found on the store floor plan for that location
when marking the floor.
When marking the location on the floor, you must use painters tape. Write the
antenna’s number on the painters tape prior to placing on the floor. You will be
required to remove the painters tape from the floor during site clean up.
Never
write on the floor. Always used painter tape. Never use electric tape or duct
tape to mark the location on the floor.
Electric tape and duct tape will damage
the floor. Painters tape does not leave marks.
5) Determine the access point to pull the coaxial cables into the stock room from the
sales floor. Use existing openings such as may be found around the bottom of the roof
girder or over the top of a roof girder.
Never use an existing opening if power
conduit or water pipes go through that opening.
You may have to cut a new
opening in the wall. If it is not possible to get the cables into the stock room from the
sales floor, then a second MEU may be required. If a second MEU is required contact
the Help Desk.
6) Determine if a firewall is present between the sales floor and the stock room. If a
firewall is present then a firewall conduit sleeve is required to pull the cables into the
stock room. You must also use Fire Stop (caulk) to seal around the sleeve.
Between the sheet
rock wall and the
ceiling