Stock Room Antenna Placement
The antennas in the stock room are normally aligned parallel along the path of the conveyor
belt starting in front of the receiving door. There must be a minimum of 10 feet separating
each antenna from the next closest antenna.
Tx-4
Tx-4 is located in the Stock Room equally spaced between Rx-15 & Rx-16. The antenna
should be placed skewed toward, and parallel to, the conveyor, yet over open floor. The
antenna should be centralized or evenly spaced between shelves on the open floor. Make
sure there are no obstructions between the antenna and floor. The antenna must be
fastened to a roof girder or to a cross-member thereof. The section of girder or cross-
member, where the antenna is to be placed, should be free of any surface-mounted
obstructions. Obstructions could include, but are not limited to, electrical hardware, HVAC
hardware, threaded support rods, or any data wiring. See the Receiver Section of this
document for specific placement of Rx-15 & Rx-16. Also, see the Exception section of this
document for instructions based upon some of the differing Stock Room layouts.
Rx-15
Rx-15 is located in the Stock Room at the opposite end of the space from the receiving
door. The antenna should be placed skewed toward, and parallel to, the conveyor, over
open floor. The antenna must be fastened to or suspended from a roof girder or to a
cross-member thereof. The section of girder or cross-member, where the antenna is to be
placed, should be free of any surface-mounted obstructions. Obstructions could include,
but are not limited to, electrical hardware, HVAC hardware, threaded support rods, or any
data wiring. Rx-15 should never be placed closer than two feet from HVAC ductwork.
Please call the Goliath Solutions Helpdesk if the previous guideline cannot be adhered to.
See the Exception section of this document for instructions based upon some of the
differing Stock Room layouts.
Rx-16
Rx-16 is located in the Stock Room directly in front of the receiving door. The antenna
should be placed skewed toward, and parallel to, the conveyor, yet over open floor. The
antenna must be fastened to or suspended from a roof girder or to a cross-member
thereof. The section of girder or cross-member, where the antenna is to be placed, should
be free of any surface-mounted obstructions. Obstructions could include, but are not
limited to, electrical hardware, HVAC hardware, threaded support rods, or any data wiring.
Rx-16 should never be placed closer than two feet from HVAC ductwork. Please call the
GOLIATH Solutions Helpdesk if the previous guideline cannot be adhered to. See the
Exception section of this document for instructions based upon some of the differing Stock
Room layouts.