LLC. This document and the information contained herein are privileged and should only be viewed by expressly authorized parties.
5/27/2008 Page: B-20
Stock Room
Access
Determine it there is an existing access point to the stock room from
the store. This access point can not be shared with water pipes.
electric conduit or A/C ductwork.
If there is not an existing access point, then determine if one can be
cut. Use the appropriate tools (drywall saw or hole saw) to cut the
hole. If it is a firewall, firewall conduit is required to be installed
according to the manufactures’ specifications.
If there is no access is available to the stock room a second MEU will
be required. Contact the Goliath Help Desk.
Tx/ATA (24)
Validate that the designated location meets the following requirements:
Clean line of site to the floor. It can not be over pipes, shelves or
merchandise stacked on the floor.
The Tx/ATA must be attached to a roof girder using cable ties.
The Tx/ATA can not touch conduit or pipes.
Tx/ATA (24) should be located about half way between Rx15 and
Rx16 next to the loading belt.
The Tx/ATA should be centered as best as possible on the aisle
between the loading belt and the shelves and over the natural
walking path.
The Tx/ATA should be a minimum of 10 feet from each Rx/ARA.
Rx/ARA (15, 16)
Validate that the designated location meets the following requirements:
Clean line of site to the floor. It can’t be over pipes, shelves or
merchandise stacked on the floor.
The Rx/ARA can be attached to a roof girder using cable ties or
suspended from the roof girder using plastic plumber’s strap.
Preferably cable tied.
The Rx/ARA can not touch conduit or pipes.
Rx (16) should be located near the start of the loading belt near the
receiving door.
Rx (15) should be located at the opposite end of the receiving belt
furthest from the receiving door.
The Rx/ARA antenna should be centered as best as possible on the
aisle between the loading belt and the shelves and over the natural
walking path.