Installation:
Installation Prep:
Unpack the Installation Kit and review its contents:
Verify you have received the correct equipment for the installation.
Once contents have been verified, begin labeling the cables for installation.
Record serial numbers for MEU and CMU.
CMU Installation:
This step will only be performed if the site is using a CMU and a MEU III. Skip this step if
you are installing an MEU I. The following steps are needed for the CMU installation.
The CMU is normally installed near the Store’s LAN cabinet. The exact location will
vary by Retailer.
The CMU/MEU power supply and cable will be plugged into an available uninterrupted
power outlet in the immediate vicinity of the CMU.
MEU Temporary Placement:
This step will only be performed if the site is using a CMU and a MEU III.
The MEU or MEU(s) will be temporarily placed and powered up within 12’ of the
location of the CMU for testing.
Cable Pulls:
Coaxial cable will be run throughout the store from the permanent location of the MEU to
the location of each one of the Tx/ATA and Rx/ARA antennas. The number of cable pulls
for a store should be minimized by combining pulls whenever possible. Perform the cable
pulls as efficiently as possible. The following standards must be followed.
All cable pulls must adhere to the Retailer Specific installation requirements.
All cables must be run through the roof girders or as required by the Retailer.
Industry cabling standards should be followed.
All equipment installed in the ceiling requires secured, self supporting service loops.
The maximum supported cable length for transmitters is 110 feet.
The maximum supported cable length of receivers is 135 feet.
If two cables are joined together an F to F BNC coupler must be used and properly
secured.