Do not unplug any power cords or network patch cables in either the
Catalina Cabinet or the free standing Communications cabinet.
3) This step is only required for a Catalina cabinet,
a) If the CMU is located in the Pharmacy proceed to step 4.
b) Open the Catalina cabinet.
c) Open the knock out hole selected during the pre-installation survey. The knock
out hole must be on either side of the cabinet.
d) Place the Power brick and the 6 foot power cord inside the Catalina cabinet. Plug
the power cable into the power brick. Do not plug the power cable into the
designated power outlet at this time.
e) Pull the CMU/MEU low voltage end of the power brick from the inside of the
cabinet through the knock out and connect it to the input power port on the CMU.
Be certain that the CMU power switch on the CMU is in the OFF position.
f) Connect the provided network patch cable to the designate port on the switch, then
pull it through the knock out hole and connect it to the CMU. If a network data
sheet is inside the communication cabinet record the port used by Goliath.
Knock Out Holes