Cód. 50121552 Audio and Video door entry system (One or several accesses doors / General door panel) Plus Nexa Instructions manual T631/PLUS ML rev.
105 INTRODUCTION First of all we would like to thank and congratulate you for the purchase of this product manufactured by Golmar. The commitment to reach the satisfaction of our customers is stated through the ISO-9001 certification and for the manufacturing of products like this one. Its advanced technology and exacting quality control will do that customers and users enjoy with the legion of features this system offers.
106 SAFETY PRECAUTIONS Install or modify the equipment without the power connected. The installation and handling of these equipments must be performed by authorised personnel. The entire installation must be at least 40 cm. away from any other installation. With power supply: wDo not use excessive force when tightening the connector screws. wInstall the power supply in a dry and protected place without risk of drip or water projections.
SYSTEM CHARACTERISTICS 107 Coming from previous page wAllows one of these functions at once, Configuration with dip switch Sw1 (see page 133): w"Autoswitch-on" function. wOutput for auxiliary relay activation (18Vdc/0,5 A maximum). wCall to a slave porter's exchange. wIntercommunication function with other monitor or telephone of the same apartment. OWith Platea Plus / Tekna Plus monitors, addition to the T-940 Plus telephones features: w"Autoswitch-on" function.
108 DOOR PANEL DESCRIPTION D oor panel description. General detail of parts, for assembly the door panel. Embedding boxes Frame modules Electronic modules Aluminium modules Door panel description. Main module Push buttons module Sound module EL631 Plus , on video systems with color camera. EL640 Plus , on audio systems. Push buttons electronic module EL610D, for 5 single push-buttons or 10 double push buttons. Short connection cable, It is supplied with EL610D module (16 cm length).
MODULES DESCRIPTION 109 s ound module description. Front side. Color camera (only EL631 Plus sound module). Speaker. Door panel audio adjustment. Monitor audio adjustment. Microphone. Sound module push buttons (x2). Back side. Function connector Cn5. Configuration dip switch SW1. Push buttons connector CN9. Configuration dip switch SW2. Push button number. CV2 CV1 _ + + _ D Ao i Ai V - - + VO la VO Mal Vi + Label. Installation terminals CN2 (Plus Nexa Bus).
110 MODULES DESCRIPTION P ush buttons electronic module EL610D description. Front side. Push buttons module (x10). Back side. Input/Output push buttons connector (x3). Configuration dip switch (Push buttons call code). Push button number.
111 DOOR PANEL INSTALLATION E mbedding box positioning. 1850 1450 1650 The upper part of the door panel should be placed at 1,65m. height roughly. The hole dimensions will depend on the type of door panel. Door panel Model An Al P 90C 90CS CEA90C CEV90C 99 143 40 99 250 56 90 CEV90 99 mm. 328 mm. 56 mm. The door panel has been designed to be placed under most of the environmental conditions. However it's recommended to take additional cautions like rainproof covers.
112 DOOR PANEL INSTALLATION P lace the embedding box. Pass the wiring through the hole made in the bottom part of the embedding box. Level and flush the embedding box. Once the embedding box is placed, remove the protective labels from the attaching door panel holes. A ssembly the electronic modules. Insert the sound module in the top part of the module frame.
113 DOOR PANEL INSTALLATION H old the frame on the embedding box. Insert the hinge that it is supplied with the product in the embedding box, as shown in the drawing. To hold the frame on the embedding box, insert the hinge in the housings arranged for this purpose in the frame, as shown in the drawing. The frame can now be folded horizontally facilitating the connection and adjustments in the sound module and push buttons electronic module. P lug the push buttons with the short connection cable.
4 DOOR PANEL INSTALLATION P lug the push buttons with the connection cable RAP-610D. Use the connection cable RAP-610D, for the connection of the push buttons between the sound module and the push buttons module EL610D and between push buttons modules EL610D, when the distance between modules to connecting is greater due to the composition of the door panels. C onfiguration of the push-buttons code.
DOOR PANEL INSTALLATION 115 D escription of the SW1 configuration dip-switch of the sound module. The SW1 configuration dip-switch is located at the upper right side of the back of the module. For dip switch settings, use the tool that is supplied with the sound module. Placed to OFF if the EL631/Plus module is configured as EL500 operating mode. Set to ON if the EL631/Plus module is configured as EL501 operating mode (general door panel).
116 DOOR PANEL INSTALLATION D escription of the SW2 configuration dip-switch of the sound module. The SW2 configuration dip-switch is located at the upper left side of the back of the module. For dip switch settings, use the tool that is supplied with the sound module. Allows to activate the autoswitch-on function (audio-video communication without previous call) at the door panel that has this switch to ON position.
GENERAL DOOR PANEL INSTALLATION 117 G eneral door panel (programming modes). Configure the EL631/Plus module of the general door panel in EL501 mode, (see page 115). The general door panel permits the following programming modes: O Programming the push button (by call of monitor). O Programming the push button (with a backbone code). O Programming the push button (with a monitor/telephone code). O Programming the monitor/telephone. P rogramming the push buttons of the general door panel.
118 GENERAL DOOR PANEL INSTALLATION Programming the push button (with a backbone code): This programming mode allows to assign a backbone code to push button of the general door panel. Locate the SW2 configuration dip switch of the general door panel to program, placed at the upper left side (back) of the sound module. With the switch 1 to ON and 3 to OFF, set the switch 2 to ON: to show that the system is ready for programming, the general door panel will reproduce a tone.
GENERAL DOOR PANEL INSTALLATION 119 P rogramming the monitors and telephones from a general door panel. Programming the monitor/telephone: This programming mode allows to assign to a monitor / telephone a push button of the general door panel that it wishes to call. Before the push button of the general door panel must be programmed with backbone and monitor/telephone code, (see page 118).
120 F DOOR PANEL INSTALLATION inal adjustments. If after starting the system it's considered that the audio volume isn't correct, proceed with the necessary adjustments as shown in the drawing. The telecamera has a pan and tilt mechanism built in to adjust the telecamera position. C lose the frame. Once finished the works of wiring, configuration and final adjustments, fix the frame in the embedding box with the supplied screws. P lace the nameplate labels. Open the label holder.
121 DOOR PANEL INSTALLATION D oor panel assembly. In assemblies of a single door panel, it is ready from factory to be mounted. If the door panel to installing is of more than one module it will be necessary make some adjustments to join a door panel with other one.
122 I POWER SUPPLY INSTALLATION nstalling the FA-PLUS and FA-PLUS/C power supplies. Install the power supply in a dry and protected place without risk of drip or water projections. To avoid an electrical shock, neither remove the primary protection cover nor handle the connected wire in the terminals. The installation and handling of these equipments must be performed by authorised personnel and without the power connected. To avoid damage, the power supply has to be firmly fixed.
123 MONITOR DESCRIPTION D escription of the Platea Plus / Tekna Plus monitor. REF PLATEA-PLUS CODE a f g b 11 7 5 8 8 0 2 10060045 VERSION 5.00 INTER A1 ATENCIÓN Alta tensión. No abrir la tapa. Manipular sólo por personal del servicio técnico. Nº SERIE 100615137263 CODIGO / CODE SLAVE MASTER ESCALERA Stair PISO Floor PUERTA Door WARNING High voltage. Don't open cover. Handle only by technical service. c h d i e j k a. b. c. d. e. f. g. h. i. j. k. l. m. Handset.
124 MONITOR DESCRIPTION F unction push buttons. On-Off push button. After any monitor reset and during the next 45 seconds, all the monitor functions will be disabled, with the exception of call reception. If the handset is on the craddle allows the activation of an optional second camera (*). If not, allows to make an intercom call or to activate the second camera (*). If the handset is on the craddle allows the activation of an optional device.
125 MONITOR ADJUSTMENTS E L562 module for video installations with twisted pair cable. Locate the CN4 connector, that's placed in the monitor base. Remove the existing jumper and plug the EL562 module. NOTE: on this type of installations the sound module must be setting with SW1-3 to ON (page 115). Refer to the specific installation diagram. H andling the end of line jumper. The end of line jumper is placed on the CN4 connector, that can be located on the monitor base.
126 MONITOR CONNECTOR DESCRIPTION D escription of the RCPL-Plus / RCTK-Plus monitor connector. a c b d 50mm. 50mm. Presionar para abrir. Press to open. Colocar la parte superior de la regleta a 1,60m. del suelo. Place the top part of the monitor connector at 1,60m. from the floor. Vin Malla Shield Malla Shield Vout A D HZINT e f SA CTO 2C A1 CODE REF 11758882 LOTE RCPL-PLUS VP MP b a a. Wall attachment hole (x4). b. Monitor attachment hook (x2). c. Vertical wiring input. d.
127 MONITOR INSTALLATION F ix the monitor connector to the wall. Avoid to place the monitor near to heating sources, in dusty locations or smoky environments. To install the monitor directly over the wall, drill two holes of Ø6mm. and use the supplied screws. The upper part of the monitor connector must be placed at 1,60m. height roughly. The minimum distance between the monitor connector and the closest object must be 5cm. F ix the monitor.
128 MONITORS PROGRAMMING P rogramming the Platea Plus / Tekna Plus monitors. Set to ON the switch number 2 of the SW2 configuration dip switch, placed at the upper left side (back) of the module EL631/Plus. The door panel will reproduce a sound to advise that the system has entered into programming mode. In systems with more than one door panel, the programming process shall be done on the master door panel only. To program the monitor from a general door panel (if it exists), see page 119.
129 TELEPHONE DESCRIPTION D escription of the T-940 Plus telephone. b d a c e a. Telephone handset. b. Speaker grille. c. Microphone hole. d. Subjection hole. e. Telephone cord connectors. f. Function push buttons. g. On-Off light indicator. h. Call reception volume control. i. Hook switch. f g e h The telephone has a three positions switch placed on the bottom part of the telephone (closest to the telephone cord connector) that allows to control the call reception level volume.
130 TELEPHONE DESCRIPTION T erminal connector description. + _ A D INT SA HZ- +,–: A,D: INT : SA : HZ- : positive, ground. audio, digital communication. intercom. auxiliary calling device output. door bell push button input. TELEPHONE INSTALLATION F ix the telephone. It will be necessary to open the telephone for wiring and fixing purposes. To open the telephone insert a plain screwdriver into the slots and rotate it as shown.
TELEPHONES PROGRAMMING P 131 rogramming the T-940 Plus telephones. Set to ON the switch number 2 of the SW2 configuration dip switch, placed at the upper left side (back) of the sound module. The door panel will reproduce a sound to advise that the system has entered into programming mode. In systems with more than one door panel, the programming process shall be done on the master door panel only. To program the telephone from a general door panel (if it exists), see page 119.
132 TELEPHONE DESCRIPTION D escription of the T-740 Plus telephone. b d a c e f h i a. Telephone handset. b. Speaker grille. c. Microphone hole. d. Subjection hole. e. Telephone cord connectors. f. Door release push button. g. Hook switch. h. Auxiliary function push button. i. Volume control. g e T erminal connector description. + _ A D Al _ HZ SA + Int PA +, - : Positive, ground. A , D : Audio, digital communication. Al : Connection to external door release push button.
133 TELEPHONE DESCRIPTION F unction push buttons. If the handset is on the craddle sends a panic call to the porter's exchanges that have enabled the reception of this type of call. If not, allows to call to the master porter's exchange. During call reception and communication progresses allows the lock release activation.
134 TELEPHONE INSTALLATION F ix the telephone to the wall. It is necessary to open the telephone for wiring and fixing purposes. To open the telephone, insert a plain screwdriver into the slots and gently lever as shown in the drawing. Avoid placing the telephone near sources of heat, in dusty locations or smoky environments. The telephone can be fixed using an electrical embedding box or directly on the wall, as shown on the picture.
TELEPHONES PROGRAMMING P 135 rogramación de los teléfonos T-740 Plus. Set to ON the switch number 2 of the SW2 configuration dip switch, placed at the upper left side (back) of the sound module. The door panel will reproduce a sound to advise that the system has entered into programming mode. In systems with more than one door panel, the programming process shall be done on the master door panel only. To program the telephone from a general door panel (if it exists), see page 119.
136 INSTALLATION DIAGRAMS C onnexion of an a.c. lock release. If an alternating current lock release has been installed, use a TF-104 transformer and connect it to the lock release as it is shown on the diagram. FA-PLUS/C rev.938072 PRI SEC 230110 0 - - + + Main L EL631 PLUS / EL640 PLUS TF-104 PRI SEC CN2 CV2 CV1 - + + - ~ ~ ~ ~ Main Lock release Va.c. ink of several power supplies units.
137 INSTALLATION DIAGRAMS Take off JP1 jumper of all the distributors except in the last one. D4L-PLUS CN4 JP1 S + _ Vin Malla Vout A D D1 E CN4 + _ Vin Malla Vout A D D2 + D4L-PLUS CN4 JP1 S + _ Vin Malla Vout A D D1 E CN4 + _ Vin Malla Vout A D D2 + M =Master. S =Slave. Access door panel CN5 Place this power supply as closest as possible to the first distributor.
138 ONE OR SEVERAL ACCESSES DOORS v ideo installation with coaxial cable. The installation diagram shows the connection of a video system with one or several door panels for the same building. If the system has one access door panel only, override the wiring to the second door panel. If the system has more than one access door panel, wire the second panel as shown on the diagram. In case of more than two door panels, wire them as the second is connected. SECTIONS CHART Distance Terminal C 50m.
139 INSTALLATION DIAGRAMS EL562 JP1 EL562 JP1 * Take off JP1 jumper of all the distributors except in the last one. + _ A D Vp Mp Md1 Vd1 + _ A D Vpo Mpo + _ A D CT + _ A D Vp Mp D6L-Plus/2H Md6 Vd6 + _ JP1 + _ A D Vpi Mpi A D CT EL562 JP1 EL562 JP1 + _ A D Vp Mp + _ A D Vp Mp Md1 Vd1 + _ A D Vpo Mpo + _ A D CT D6L-Plus/2H Md6 Vd6 + _ JP1 + _ A D Vpi Mpi A D CT M =Master. S =Slave. Access door panel CN5 * Place this power supply as closest as possible to the first distributor.
140 ONE OR SEVERAL ACCESSES DOORS v ideo installation without coaxial cable. The installation diagram shows the connection of a video system with one or several door panels for the same building. If the system has one access door panel only, override the wiring to the second door panel. If the system has more than one access door panel, wire the second panel as shown on the diagram. In case of more than two door panels, wire them as the second is connected.
141 INSTALLATION DIAGRAMS T-740 Plus T-940 Plus + _ A D + _ A D T-940 Plus T-740 Plus + _ A D + _ A D M =Master. S =Slave. Access door panel CN5 *Place this power supply as closest as possible to the first telephone. FA-Plus/C o FA-Plus PRI ~ ~ Main SEC + + - - P 10 9 8 7 6 1 3 4 2 SW2 5 SW1 CN2 CV2 CV1 - + + - D Aout Ain Vin- Vin+ Malla Vout+ Vout- Lock release Vd.c.
142 ONE OR SEVERAL ACCESSES DOORS A udio installation. The installation diagram shows the connection of an audio system with one or several door panels for the same building. If the system has one access door panel only, override the wiring to the second door panel. If the system has more than one access door panel, wire the second panel as shown on the diagram. In case of more than two door panels, wire them as the second is connected. SECTIONS CHART Distance Terminal 50m. 150m.
143 INSTALLATION DIAGRAMS BACKBONE 1 To monitors Inner door panel CN5 8 7 6 1 3 4 FA-Plus o FA-Plus/C PRI ~ ~ P 10 9 2 5 EL500 mode SW2 SW1 CN2 CV2 CV1 - + + - D Aout Ain Vin- Vin+ Malla Vout+ Vout- SEC + + - - Lock release Vd.c. Main D4L-PLUS JP1 E S S1 + General door panel BACKBONE 0 M =Master. CN5 S =Slave. FA-Plus/C rev.
144 GENERAL DOOR PANEL BACKBONE 2 To monitors Inner door panel CN5 8 7 6 1 3 4 2 FA-Plus o FA-Plus/C PRI ~ ~ P 10 9 5 EL500 mode SW2 SW1 CN2 CV2 CV1 - + + - D Aout Ain Vin- Vin+ Malla Vout+ Vout- SEC + + - - Lock release Vd.c. Main D4L-PLUS E S1 S + General door panel BACKBONE 0 CN5 FA-Plus/C rev.
145 INSTALLATION DIAGRAMS BACKBONE 119 To monitors Inner door panel CN5 FA-Plus o FA-Plus/C 8 7 6 1 3 4 2 SW2 5 EL500 mode SW1 CN2 CV2 CV1 - + + - D Aout Ain Vin- Vin+ Malla Vout+ Vout- SEC + + - - PRI ~ ~ P 10 9 Lock release Vd.c. Main D4L-PLUS JP1 E S1 + S S2 Coming from previous page v ideo installation with general door panel to large residential complexes. IMPORTANT NOTES: To install and configure properly, do always follow the enclosed information.
146 GENERAL DOOR PANEL BACKBONE 120 To monitors Inner door panel CN5 8 7 6 1 3 4 2 FA-Plus o FA-Plus/C EL500 mode 5 SW2 SW1 CN2 CV2 CV1 - + + - D Aout Ain Vin- Vin+ Malla Vout+ Vout- SEC + + - - PRI ~ ~ P 10 9 Lock release Vd.c. Main v ideo installation with general door panel to large residential complexes. SECTIONS CHART Terminal Distance 100m. 300m.
147 INSTALLATION DIAGRAMS To telephones BACKBONE 1 Inner door panel CN5 8 7 6 1 3 4 FA-Plus o FA-Plus/C PRI ~ ~ P 10 9 2 5 EL500 mode SW2 SW1 CN2 CV2 CV1 - + + - D Aout Ain Vin- Vin+ Malla Vout+ Vout- SEC + + - - Lock release Vd.c. Main CN5 S =Slave. FA-Plus/C rev.938072 PRI SEC 230 110 0 - - + + Main General door panel BACKBONE 0 M =Master.
148 GENERAL DOOR PANEL To telephones BACKBONE 120 Inner door panel CN5 FA-Plus o FA-Plus/C PRI ~ ~ P 10 9 8 7 6 1 3 4 2 EL500 mode 5 SW2 SW1 CN2 CV2 CV1 - + + - D Aout Ain Vin- Vin+ Malla Vout+ Vout- SEC + + - - Lock release Vd.c. Main A IMPORTANT NOTES: udio installation with general door panel to large residential complexes. To install and configure properly, do always follow the enclosed information.
149 OPTIONAL CONNECTIONS E xternal lock release activation. Placa The lock release can be activated at any moment by using an external push button, that must be connected between 'AP' and '–' terminals of the connector Cn5 from door panel (see page 119). Door opening timed at 3 or 15 seconds, with the help of the dip switch SW1-2 (see page 115). This function will allows to exit from the building being not necessary the use of a key. CN5 10 9 8 7 6 1 3 4 2 5 CN2 CV2 CV1 - AP Lock release Vd.c.
150 A OPTIONAL CONNECTIONS uxiliary devices activation. To activate auxiliary devices the use of a SAR-12/24 relay unit will be required. If this device is shared for all monitors, link their A1 terminal and use just one relay unit. In case that each monitor has its own application use a SAR-12/24 relay unit for each monitor and don't link the A1 monitor terminals. To activate this function, press monitor push button at any moment with no dependence of the handset position.
151 OPTIONAL CONNECTIONS A ctivation of a second camera. The use of a SAR-12/24 relay will be required to activate a second camera and an internal modification on the monitor shall be done, as it's described on page 124. This facility disables the intercom function. If both functions are required, use A1 terminal to activate the second camera. To activate this function, press monitor push button at any moment with no dependence of the handset position.
152 I OPTIONAL CONNECTIONS ntercom function. Platea Plus / Tekna Plus monitor and (*) T-740Plus and T-940 Plus telephones have intercom facility between two units of the same apartment. To enable this function check the following conditions: - One of the units has been configurated as master and the other unit as slave with intercom, as described on pages 128, 131 and 135. In case to intercom one monitor with one telephone, configure the monitor as master.
153 OPTIONAL CONNECTIONS A uxiliary devices activation with T-740 Plus telephone. First the T-740 Plus telephone must be configured with SW1 dip switch in "PA" output mode function (see page 133). To activate auxiliary devices the use of a SAR-12/24 relay unit will be required. If this device is shared for all the T-740 Plus telephones, link their PA terminal and use just one relay unit.
154 TROUBLESHOOTING HINTS An easy way to check that the system is working properly is to disconnect the wiring from the door panel and to check the monitor directly connected to the sound module. No shortcircuit will damage the connected units, with the exception of a shortcircuit between CTO and '–' monitor or distributor terminals. O Nothing operates. w Check the output power supply voltage between '–' and '+' terminals: it should have 17,5 to 18,5Vd.c.
CONFORMIDAD/COMPLIANCE/CONFORMITÉ 155 Este producto es conforme con las disposiciones de las Directivas Europeas aplicables respecto a la Seguridad eléctrica 2006/95/CEE y la Compatibilidad Electromagnética 2004/108/CEE, así como con la ampliación en la Directiva del Marcado CE 93/68/CEE. This product meets the essentials requirements of applicable European Directives regarding Electrical Safety 2006/95/ECC, Electromagnetic Compatibility 2004/108/ECC, and as amended for CE Marking 93/68/ECC.