User manual

19
User manual
5.3 Use of 230 V AC outputs
1. Use only devices that are equipped either with safety plug or European
cable connectors.
2. Turnthevoltageconverteron(ON).
3. Make sure that the device to be connected is switched off.
4. Connect the plug of the device to be connected with the 230 V AC output
(7) of the voltage converter.
5.4 Use of the 5V USB DC output
Material damage
Do not connect memory sticks, MP3 player or similar external data
storage devices.
1. Turnthevoltageconverteron(ON).
2. Connect a USB device to the USB 5V DC connector (9).
The 5V USB DC connection of the voltage converter provides 5 V DC power
for USB devices such as lights, fans and radios.
The 5V USB DC connection of the voltage converter is not provided for data
transmission.
6 Troubleshooting
Function Status description Method for restart
LED Alarm AC
output
Input low-voltage-
alarm
green
on,
red off
yes yes Does the battery
voltage become
usual, the alarm stops
automatically.
Input low-voltage
shutdown
green
+red on
No No Charge the battery.
• Switch off the volta-
ge converter for 3-5
seconds.
• Switch on the volta-
ge converter.
Input over-volta-
ge shutdown
green
+red on
No No • Check battery for
correct voltage or
asure it.
• Switch off the volta-
ge converter for 3-5
seconds.
• Switch on the volta-
ge converter.