6.2 Modelsforxedinstallation
Risk of electric shock
LetopencableendsONLYassemblebyexperienced
electrician.
Cut off power supply before any work on the product,
switch off safety fuse and secure against reconnection.
Assure and check the absence of voltage before any
work on the product.
Models without a mated protective contact plug must be permanently instal-
led on the power supply.
Thepowercablesusedmusthaveaminimumcross-sectionof1.0mm².
Strandsmustbeprovidedwithwireendferrules.Thefollowingconnections
are made at the luster terminal of the product:
6 mm 15 mm
N
L
GND
1 2 3
4 5 6
Fi g. 14: Fixed installation
1. Turnoffthefuse.
2. Opentheconnectionsleevebyturningitcounter-clockwiseuntilthe
connection block is released as shown in Fig. 7 - 2.
3. Insulate the cables as shown in Fig. 7 - 3.
4. Slide the parts of the connection sleeve shown in Figs. 7 - 4 over the
connection cable.
5. Screw the power cables as shown in Fig. 7 - 5 using a screwdriver.
6. Close the connector by turning it clockwise, as shown in Figure 7 - 6.