User manual
20
6.2 Modelsforxedinstallation
Risk of electric shock
• LetopencableendsONLYassemblebyexperienced
electrician.
• Cut off power supply before any work on the product,
switch off safety fuse and secure against reconnection.
• Assure and check the absence of voltage before any
work on the product.
Models without a mated protective contact plug must be permanently instal-
led on the power supply.
Thepowercablesusedmusthaveaminimumcross-sectionof1.0mm².
Strandsmustbeprovidedwithwireendferrules.Thefollowingconnections
are made at the luster terminal of the product:
6 mm 15 mm
N
L
GND
1 2 3
4 5 6
Fi g. 14: Fixed installation
1. Turnoffthefuse.
2. Opentheconnectionsleevebyturningitcounter-clockwiseuntilthe
connection block is released as shown in Fig. 7 - 2.
3. Insulate the cables as shown in Fig. 7 - 3.
4. Slide the parts of the connection sleeve shown in Figs. 7 - 4 over the
connection cable.
5. Screw the power cables as shown in Fig. 7 - 5 using a screwdriver.
6. Close the connector by turning it clockwise, as shown in Figure 7 - 6.