Rated load
max.1200W(incandescentlamps),
max.300W(energy-savinglamps)
Powerconsumption ~0.9 W
Detection area 2-6m(<24°C)
Detection angle 120/360° wall/ceiling installation
Switch-off delay 10/30/93 s, 3/6/12±1 Min.
Brightness sensitivity
<3-2000 lx / day and night (
)
HF System 5.8GHzCWRadar,ISMBand
Transmissionpower <0,2 mW
Ceiling mounting height 2-6 m
Motion detection 0.6-1.5 m/s
Protection level IP20
Environment conditions -20 ~ +40 °C, 93 % RH
Switch Triac
Dimensions Ø115 x 24 mm
Borehole diameter ~62 mm
Weight 65 g
Ta b . 3 : Specications