TECHNICAL MANU AL MANUAL GPC 14 SEER R-410A Package Air Conditioners with R-410A • Refer to Service Manual RS6300011 (Horizontal) for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • Models listed on page 3.
PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information.
PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. 5mm GPC1424H41AA GPC1424H41AB GPC1430H41AA GPC1436H41AA GPC1430H41AB GPC1436H41AB GPC1442H41AA GPC1448H41AA GPC1442H41AB GPC1448H41AB GPC1460H41AA AB model specific 5 mm information begins on page 28.
PRODUCT DESIGN GPC Package Cooling Units are designed for outdoor installations only in either residential or light commercial applications. - Due to their design Scroll Compressors are inherently more tolerant of liquid refrigerant. NOTE: Even though the compressor section of a Scroll compressor is more tolerant of liquid refrigerant, continued floodback or flooded start conditions may wash oil from the bearing surfaces causing premature bearing failure.
PRODUCT DESIGN In installations where the unit is installed above ground level and not serviceable from the ground (Example: Roof Top installations), the installer must provide service platform for service person with rails or guards in accordance with local codes or ordinances or in their absence with the latest edition of the Uniform Mechanical Code Section 305. 36" UN I T NOTE: Unit can also use roof curb.
PRODUCT DIMENSIONS GPC14[24-60]H41A* A 14.000 4.512 4.500 14.000 SUPPLY 6.500 14.000 RETURN BACK VIEW (DUCT OPENINGS) 66.542 B 34.
PRODUCT DESIGN GPC14[24-60]H41A* HKR ELECTRICAL DATA Circuit #1 Model and Heat Kit Usage GPH1424H41A* HKR05*,C* HKR08*,C* HKR10*,C* GPH1430H41A* HKR05*,C* HKR08*,C* HKR10*,C* HKR15*,C* GPH1436H41A* HKR05*,C* HKR08*,C* HKR10*,C* HKR15*,C* GPH1442H41A* HKR05*,C* HKR08*,C* HKR10*,C* HKR15*,C* HKR20*,C* GPH1448H41A* HKR05*,C* HKR08*,C* HKR10*,C* HKR15*,C* HKR20*,C* GPH1460H41A* HKR05*,C* HKR08*,C* HKR10*,C* HKR15*,C* HKR20*,C* Circuit #2 Minimum Circuit Ampacity at 208 / 240V Maximum Overcurrent Protectio
GPC14[24-60]H41A* ACCESSORIES Part Number 8 Description OT18-60A Outdoor Thermostat Kit w/Lockout Stat OT/EHR18-60 Emergency Heat Relay Kit HKR Electric Heat Kit PCCP101-103 Roof Curb PCP101-103 Downflow Plenum Kit PCP101-103R8 Downflow Plenum Kit w/ R-8 Insulation GPCED101-103 Downflow Economizer for GPC-(H) A/C - To Be Used With PCP101-103 GPHED101-103 Downflow Economizer for GPH-(H) Heat Pump - To Be Used With PCP101-103 GPCEH101-103 Horizontal Economizer for GPC-(H) A/C GPHEH101-10
GPC14[24-60]H41A* BLOWER PERFORMANCE DATA Dry Coil Data GPC1460H41** GPC1448H41** GPC1442H41** GPC1436H41** GPC1430H41** GPC1424H41** Model Speed T1 Volts 230 T2,T3 230 T4, T5 230 T1 230 T2,T3 230 T4, T5 230 T1 T2,T3 T4, T5 T1 T2,T3 T4, T5 T1 T2,T3 T4, T5 T1, T2, T3 T4, T5 230 230 230 230 230 230 230 230 230 230 230 E.S.P (In. of H2O) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.
10 20 30 40 50 60 70 30 80 90 100 40 50 60 700 600 CFM 90 100 2000 2200 2400 CFM 1800 1600 1400 OUTPUT BTU/HR x 1000 80 1200 1100 1000 900 70 800 FORMULAS 110 120 130 140 BTU OUTPUT = CFM x 1.08 x RISE BTU OUTPUT RISE = ÷ CFM 1.
PACKAGE COOLING SPECIFICATIONS GPC14[24-30]H41AA GPC1424H41* GPC1430H41* 24,600 28,400 14.5 / 12.1 14.0 / 12.1 208-230/1/60 208-230/1/60 10.5 13.16 12.5 15.6 20 25 RECIP RECIP RATED LOAD AMPS 7.9 9.8 LOCKED ROTOR AMPS 41 55 CONDENSER HORSEPOWER 1/6 1/4 FAN MOTOR RPM 815 830 FULL LOAD AMPS 1.1 1.
PACKAGE COOLING SPECIFICATIONS COOLING COOLING CAPACITY, BTUH CAPACITY SEER / EER UNIT VOLTAGE (NAMEPLATE) ELECTRICAL AMPS (TOTAL) SPECIFICATION MINIMUM CIRCUIT AMPACITY MAXIMUM OVERCURRENT PROTECTION COMPRESSOR (1) TYPE RATED LOAD AMPS LOCKED ROTOR AMPS GPC14[36-42]H41AA GPC1436H41* GPC1442H41* 35,600 40,000 14.0 / 12.0 14.2/ 12.0 208-230/1/60 208-230/1/60 20.06 22.2 24.2 26.6 40 40 SCROLL SCROLL 16.7 17.
PACKAGE COOLING SPECIFICATIONS COOLING COOLING CAPACITY, BTUH CAPACITY SEER / EER UNIT VOLTAGE (NAMEPLATE) ELECTRICAL AMPS (TOTAL) SPECIFICATION MINIMUM CIRCUIT AMPACITY (1) GPC14[48-60]H41AA GPC1448H41* GPC1460H41* 46,500 57,500 14.5 / 12.0 14.5 / 12.0 208-230/1/60 208-230/1/60 24.2 30.7 29.1 37.3 45 60 SCROLL SCROLL RATED LOAD AMPS 19.9 26.4 LOCKED ROTOR AMPS 109 134 CONDENSER HORSEPOWER 1/4 1/4 FAN MOTOR RPM 1075 1075 FULL LOAD AMPS 1.4 1.4 LOCKED ROTOR AMPS 2.
EXPANDED PERFORMANCE DATA 21.6 0.68 18 1.52 6.4 224 107 24.5 0.84 20 1.58 6.7 236 112 23.8 0.81 21 1.57 6.6 233 111 22.0 0.78 21 1.53 6.5 226 108 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 850 745 955 850 745 22.6 0.69 19 1.56 6.6 244 115 24.5 0.72 19 1.60 6.8 251 118 25.2 0.76 18 1.62 6.8 254 120 22.4 0.57 16 1.55 6.6 241 114 24.3 0.59 16 1.59 6.7 249 117 24.5 0.53 16 1.61 6.
EXPANDED PERFORMANCE DATA 85 80 22.4 0.85 24 1.54 6.5 229 109 25.4 0.97 24 1.61 6.8 241 115 24.6 0.93 25 1.60 6.8 238 114 22.7 0.89 25 1.56 6.6 231 110 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 850 745 955 850 745 23.2 0.86 25 1.59 6.7 249 117 25.1 0.89 24 1.63 6.9 256 121 25.9 0.94 23 1.64 7.0 259 122 22.8 0.80 23 1.58 6.7 246 116 24.8 0.83 22 1.62 6.8 254 120 24.3 0.78 23 1.64 6.
EXPANDED PERFORMANCE DATA 27.5 0.82 20 1.86 7.7 240 111 25.4 0.79 20 1.81 7.5 232 108 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1180 920 1050 28.3 0.86 19 1.88 7.8 242 113 MBh S/T Delta T KW AMPS HI PR LO PR 920 28.3 0.74 18 1.90 7.9 258 119 26.1 0.71 19 1.85 7.7 250 115 29.1 0.77 18 1.92 7.9 260 120 25.8 0.58 15 1.84 7.6 248 114 30.6 0.56 15 1.96 8.1 272 129 28.3 0.54 15 1.92 7.9 264 126 31.5 0.58 14 1.98 8.2 275 131 28.3 0.40 11 1.90 7.8 261 124 32.9 0.
EXPANDED PERFORMANCE DATA 85 80 25.8 0.87 22 1.83 7.6 235 109 29.3 0.99 23 1.91 7.9 247 115 28.5 0.95 24 1.89 7.8 244 114 26.3 0.91 24 1.84 7.6 237 110 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1050 920 1180 1050 920 26.8 0.88 24 1.89 7.8 255 117 29.0 0.91 23 1.93 8.0 263 121 29.9 0.96 22 1.95 8.1 266 122 26.4 0.82 22 1.87 7.7 253 116 28.6 0.85 21 1.92 7.9 260 120 28.0 0.80 22 1.95 8.
EXPANDED PERFORMANCE DATA 34.4 0.83 22 2.33 10.5 238 107 31.8 0.80 22 2.27 10.3 231 104 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1349 1052 1200 35.5 0.87 21 2.35 10.6 241 109 MBh S/T Delta T KW AMPS HI PR LO PR 1052 35.5 0.74 20 2.38 10.8 256 114 32.7 0.71 20 2.32 10.5 249 111 36.5 0.77 19 2.40 10.8 259 116 32.4 0.58 17 2.30 10.4 246 110 38.4 0.56 16 2.45 11.0 271 125 35.4 0.54 17 2.39 10.8 263 121 39.5 0.59 16 2.47 11.1 273 126 35.5 0.41 13 2.37 10.
EXPANDED PERFORMANCE DATA 85 80 32.4 0.87 25 2.29 10.4 233 105 36.7 1.00 25 2.39 10.8 245 111 35.7 0.95 26 2.37 10.7 243 110 32.9 0.92 26 2.31 10.5 236 106 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1200 1052 1349 1200 1052 33.6 0.88 26 2.36 10.7 254 113 36.4 0.92 26 2.42 10.9 261 117 37.4 0.96 25 2.44 11.0 264 118 33.1 0.82 24 2.34 10.6 251 112 35.8 0.85 23 2.40 10.8 259 116 35.1 0.
EXPANDED PERFORMANCE DATA 39.2 0.81 23 2.54 11.6 236 110 36.2 0.79 23 2.48 11.3 229 106 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1461 1139 1300 40.4 0.85 22 2.56 11.7 238 111 MBh S/T Delta T KW AMPS HI PR LO PR 1139 40.3 0.73 21 2.60 11.8 254 117 37.2 0.70 21 2.53 11.5 246 113 41.6 0.76 20 2.62 11.9 257 118 36.9 0.58 17 2.51 11.4 244 112 43.7 0.55 17 2.68 12.1 268 127 40.3 0.53 17 2.62 11.9 260 123 45.0 0.58 16 2.70 12.2 271 128 40.4 0.40 13 2.59 11.
EXPANDED PERFORMANCE DATA 85 80 36.8 0.86 26 2.50 11.4 231 107 41.8 0.98 26 2.61 11.8 243 113 40.6 0.94 27 2.58 11.8 241 112 37.5 0.90 27 2.52 11.5 234 108 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1300 1139 1461 1300 1139 38.2 0.87 27 2.58 11.7 251 115 41.4 0.90 26 2.64 12.0 259 119 42.6 0.95 25 2.66 12.1 262 120 37.6 0.81 25 2.56 11.6 249 114 40.8 0.84 24 2.62 11.9 257 118 40.0 0.
EXPANDED PERFORMANCE DATA 45.0 0.83 21 2.94 12.7 236 110 41.5 0.80 22 2.87 12.4 229 107 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1800 1400 1600 46.3 0.87 21 2.97 12.8 238 112 MBh S/T Delta T KW AMPS HI PR LO PR 1400 46.3 0.74 20 3.01 13.0 254 118 42.8 0.71 20 2.93 12.7 246 114 47.7 0.78 19 3.03 13.1 256 119 42.3 0.59 16 2.91 12.6 243 113 50.1 0.56 16 3.10 13.4 268 128 46.3 0.54 16 3.03 13.1 260 124 51.6 0.59 15 3.13 13.5 270 130 46.4 0.41 12 3.00 13.
EXPANDED PERFORMANCE DATA 85 80 42.3 0.87 24 2.90 12.5 231 108 48.0 1.00 24 3.01 13.1 243 114 46.6 0.95 25 2.99 13.0 240 113 43.0 0.92 26 2.92 12.6 233 109 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1600 1400 1800 1600 1400 43.8 0.88 25 2.98 12.9 251 116 47.5 0.92 25 3.05 13.2 259 120 48.9 0.96 24 3.08 13.3 261 121 43.2 0.82 23 2.96 12.8 248 115 46.8 0.85 23 3.03 13.1 256 119 45.9 0.
EXPANDED PERFORMANCE DATA 55.6 0.77 25 3.70 15.7 238 108 51.3 0.75 25 3.61 15.3 231 105 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1800 1400 1600 57.3 0.81 24 3.73 15.8 241 109 MBh S/T Delta T KW AMPS HI PR LO PR 1400 57.3 0.69 23 3.79 16.0 256 115 52.9 0.67 23 3.69 15.6 249 111 59.0 0.73 22 3.82 16.2 259 116 52.3 0.55 19 3.66 15.5 246 110 62.0 0.52 19 3.91 16.5 271 125 57.2 0.51 19 3.81 16.1 263 121 63.9 0.55 18 3.94 16.7 273 126 57.3 0.38 14 3.78 16.
EXPANDED PERFORMANCE DATA 85 80 52.3 0.82 28 3.64 15.4 233 106 59.3 0.93 28 3.80 16.1 245 111 57.6 0.89 29 3.77 16.0 243 110 53.2 0.86 30 3.67 15.6 236 107 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1600 1400 1800 1600 1400 54.2 0.83 30 3.75 15.9 254 113 58.7 0.86 29 3.85 16.3 262 117 60.5 0.90 28 3.88 16.5 264 118 53.4 0.77 27 3.72 15.8 251 112 57.9 0.80 26 3.82 16.2 259 116 56.8 0.
COOLING PERFORMANCE DATA PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low and high side pressures and power will not change. 2.
WIRING DIAGRAMS GPC14[24-60]H41AA PU NOTE #3 BK BK 1 2 3 C 208 240 PU PU BL BK BL 24V RD C WARNING HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
GPC 14 SEER R-410A 5mm Package Air Conditioners GPC1424H41AB GPC1430H41AB GPC1436H41AB GPC1442H41AB GPC1448H41AB PRODUCT DESIGN GPC Package Cooling Units are designed for outdoor installations only in either residential or light commercial applications. The connecting ductwork (Supply and Return) can be connected for either horizontal or vertical airflow. In the vertical application a matching Roof Curb is recommended.
PRODUCT DESIGN Location and Clearances NOTE: To ensure proper condensate drainage, unit must be installed in a level position. In installations where the unit is installed above ground level and not serviceable from the ground (Example: Roof Top installations), the installer must provide service platform for service person with rails or guards in accordance with local codes or ordinances or in their absence with the latest edition of the Uniform Mechanical Code Section 305.
MODELS WITH 5MM COILS PACKAGE COOLING SPECIFICATIONS GPC14[24-30]H41AB G PC1424H 41AB GPC14 30H41AB 24,600 28,400 14.5 / 12.1 14.0 / 12.1 208-230/1/60 208-230/1/60 COOL ING CO OLING CAPACITY, BTUH CAPACITY SEER / EER UNIT VO LT AG E (NAMEPLATE) ELECTRICAL AMPS (TO TAL) 16.1 15.76 SPECIFICATION MINIMUM CIRCUIT AMPACITY 19.5 19 30 30 SCROLL SCROLL RATED LOAD AMPS 13.5 12.8 LOCKED RO TO R AMPS 58.
MODELS WITH 5MM COILS PACKAGE COOLING SPECIFICATIONS GPC14[36-48]H41AB GPC1436H41AB GPC1442H41AB GPC1448H41AB 35,600 40,000 46,500 14.0 / 12.0 14.2 / 12.0 14.5 / 12.0 208-230/1/60 208-230/1/60 208-230/1/60 COOLING COOLING CAPACITY, BTUH CAPACITY SEER / EER UNIT VOLTAGE (NAMEPLATE) ELECTRICAL AMPS (TOTAL) 20.06 22.2 24.2 SPECIFICATION MINIMUM CIRCUIT AMPACITY 24.2 26.6 29.1 40 40 45 SCROLL SCROLL SCROLL 16.7 17.9 19.
21.6 0.68 19 1.42 6.4 214 106 24.5 0.84 21 1.48 6.6 225 111 23.8 0.80 21 1.47 6.6 223 110 22.0 0.77 22 1.43 6.4 216 107 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 720 920 24.5 0.72 20 1.50 6.7 240 117 22.6 0.69 20 1.46 6.6 232 114 25.2 0.75 19 1.51 6.8 242 119 22.4 0.57 16 1.45 6.5 230 113 63 25.0 0.62 15 1.50 6.7 240 117 24.3 0.59 16 1.49 6.7 237 116 26.5 0.54 16 1.55 6.9 253 128 24.5 0.
25.4 0.97 25 1.50 6.7 229 114 MBh S/T Delta T KW AMPS HI PR LO PR 920 25.9 0.93 24 1.54 6.9 247 121 24.8 0.83 23 1.51 6.8 242 119 22.8 0.80 23 1.47 6.6 235 115 27.1 0.84 23 1.59 7.1 261 132 26.4 0.67 20 1.56 7.0 256 129 24.4 0.65 20 1.52 6.8 248 126 67 27.2 0.70 19 1.57 7.0 258 131 28.9 0.68 20 1.64 7.3 272 141 28.3 0.50 16 1.61 7.2 267 138 26.1 0.48 16 1.57 7.0 259 134 71 29.1 0.53 15 1.63 7.2 269 139 24.8 1.00 25 1.62 7.2 257 120 23.7 0.91 24 1.60 7.1 252 118 21.8 0.88 25 1.56 6.
27.0 0.71 17 1.73 7.9 232 107 25.7 0.68 18 1.70 7.7 227 105 28.3 0.84 19 1.76 8.0 237 109 27.5 0.80 20 1.75 7.9 234 108 26.1 0.77 21 1.72 7.8 230 106 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1020 900 1145 1020 900 26.9 0.69 19 1.76 8.0 247 112 28.3 0.72 18 1.79 8.1 252 115 29.1 0.75 18 1.80 8.1 255 116 26.6 0.57 15 1.74 7.9 245 111 28.0 0.59 15 1.
29.3 0.97 23 1.79 8.1 241 111 MBh S/T Delta T KW AMPS HI PR LO PR 1145 29.9 0.93 22 1.83 8.3 260 118 28.6 0.83 21 1.80 8.1 255 116 27.1 0.79 22 1.77 8.0 250 114 31.3 0.84 21 1.89 8.5 274 129 30.5 0.67 19 1.86 8.4 269 127 29.0 0.64 19 1.83 8.2 264 124 67 31.4 0.71 18 1.87 8.4 272 128 33.4 0.68 18 1.95 8.8 286 138 32.6 0.50 15 1.92 8.6 281 135 31.0 0.48 15 1.89 8.5 275 132 71 33.6 0.53 14 1.94 8.7 283 136 28.6 1.00 23 1.93 8.7 271 117 27.3 0.91 22 1.90 8.5 266 115 25.9 0.87 23 1.87 8.
32.1 0.68 19 2.30 9.9 227 106 36.4 0.84 21 2.39 10.3 238 111 35.4 0.81 22 2.37 10.3 236 110 32.7 0.78 22 2.32 10.0 229 107 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1052 1350 36.4 0.72 20 2.42 10.5 254 117 33.6 0.69 20 2.36 10.2 246 114 37.5 0.76 19 2.44 10.5 257 119 33.3 0.57 17 2.35 10.1 244 113 63 37.1 0.62 16 2.42 10.5 254 117 36.1 0.59 16 2.40 10.4 251 116 39.4 0.55 16 2.50 10.
.7 0.97 25 2.43 10.5 243 114 MBh S/T Delta T KW AMPS HI PR LO PR 1350 38.5 0.94 25 2.48 10.7 262 121 36.8 0.83 23 2.44 10.6 257 119 34.0 0.80 24 2.38 10.3 249 115 40.3 0.85 23 2.56 11.0 276 132 39.3 0.67 20 2.52 10.8 271 129 36.3 0.65 21 2.46 10.6 263 126 67 40.5 0.71 20 2.54 10.9 274 131 43.0 0.69 20 2.65 11.4 288 141 42.0 0.50 16 2.60 11.2 283 138 38.8 0.49 16 2.54 10.9 274 134 71 43.3 0.53 16 2.62 11.3 285 139 36.9 1.00 25 2.62 11.2 273 120 35.2 0.92 25 2.58 11.1 268 118 32.5 0.88 25 2.
35.7 0.66 20 2.60 11.0 232 105 40.5 0.82 21 2.70 11.5 244 110 39.3 0.78 22 2.68 11.4 241 109 36.3 0.75 23 2.62 11.1 234 106 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1116 1432 40.5 0.70 20 2.74 11.7 260 116 37.3 0.68 21 2.67 11.4 252 112 41.7 0.73 20 2.76 11.8 262 117 37.0 0.55 17 2.65 11.3 249 111 63 41.3 0.60 16 2.74 11.7 260 116 40.1 0.58 17 2.72 11.6 257 115 43.8 0.53 17 2.82 12.
1432 42.7 0.91 25 2.80 12.0 268 119 44.7 0.82 24 2.89 12.4 283 130 67 45.0 0.69 20 2.87 12.3 280 129 43.7 0.66 21 2.85 12.2 277 128 40.3 0.63 21 2.78 11.8 269 124 47.7 0.67 20 2.99 12.8 295 139 71 48.1 0.51 16 2.96 12.7 292 138 46.7 0.49 17 2.94 12.6 289 136 43.1 0.47 17 2.87 12.3 280 132 40.9 0.98 26 2.96 12.6 279 119 59 40.2 0.93 24 2.93 12.5 276 117 39.1 0.89 25 2.91 12.4 274 116 36.1 0.86 25 2.84 12.1 265 113 41.7 0.94 25 3.02 12.9 300 126 63 41.1 0.88 23 3.00 12.8 297 125 39.9 0.83 24 2.97 12.
41.3 0.69 19 2.30 12.7 223 106 46.9 0.85 21 2.42 13.3 235 112 45.5 0.81 22 2.39 13.2 233 111 42.0 0.78 22 2.32 12.8 226 108 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1386 1777 46.9 0.73 20 2.46 13.4 250 118 43.3 0.70 20 2.38 13.1 243 114 48.3 0.76 19 2.48 13.5 253 119 42.8 0.58 16 2.36 13.0 240 113 63 47.8 0.63 15 2.46 13.4 250 118 46.4 0.60 16 2.43 13.3 248 117 50.8 0.55 16 2.56 13.
1777 49.5 0.95 24 2.53 13.8 258 122 51.9 0.85 23 2.63 14.2 272 133 67 52.1 0.71 19 2.61 14.1 270 131 50.6 0.68 20 2.58 13.9 267 130 46.7 0.66 20 2.50 13.6 259 126 55.3 0.69 20 2.74 14.6 284 141 71 55.7 0.53 15 2.71 14.5 281 140 54.1 0.51 16 2.68 14.4 278 139 49.9 0.49 16 2.60 14.1 270 134 47.4 1.00 25 2.71 14.4 269 121 59 46.6 0.97 23 2.68 14.3 266 119 45.3 0.92 24 2.65 14.2 264 118 41.8 0.89 25 2.57 13.9 256 115 48.4 0.98 25 2.78 14.8 289 128 63 47.6 0.91 22 2.75 14.6 286 127 46.3 0.87 23 2.72 14.
COOLING PERFORMANCE DATA PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low and high side pressures and power will not change. 2.
WIRING DIAGRAMS 5MM COILS PU GPC14[24-48]H41AB NOTE #3 BK BK PU PU BL C BK BL RD T2 RD C WARNING HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.