DSZC18 Split System Heat Pump Cooling Capacity: 35,000 - 56,500 BTU/h up to Heating Capacity: 33,600 - 56,400 BTU/h 18 SEER R-410A Standard Features • • • • • • • • • • • • • • • • • • • R-410A chlorine-free refrigerant Two-Stage Copeland® UltraTech scroll compressor High-density foam compressor sound blanket ComfortNet™ Communications System compatible Expanded ComfortAlert diagnostics built in Set-up capable with two low-voltage wires to outdoor unit Diagnostic indicator lights and storage of six fa
Product Specifications Nomenclature D 1 S 2 Z 3 C 4 18 5,6 036 7,8,9 1 10 A 11 A 12 Brand D Goodman® Brand Engineering * Minor Revision Product Category S Split System Unit Type X Condenser R-‐410A Z Heat Pump R-‐410A Engineering * Major Revision 1 2 3 4 Communica9on Feature C ComfortNet 4-‐wire communicaQons ready Efficiency 13 13 SEER 14 14 SEER 024 036 16 16 SEER 18 18 SEER Electrical 208/230 V, 1 Phase, 60
Product Specifications Specifications Cooling Capacity Nominal Cooling (BTU/h) Nominal Heating (BTU/h) Decibels Compressor RLA LRA Condenser Fan Motor Horsepower (RPM) FLA Refrigeration System Refrigerant Line Size¹ Liquid Line Size (“O.D.) Suction Line Size (“O.D.) Refrigerant Connection Size Liquid Valve Size (“O.D.) Suction Valve Size (“O.D.
www.goodmanmfg.com 25.2 0.87 21 1.35 5.4 211 112 24.5 0.83 22 1.34 5.3 209 111 22.6 0.80 22 1.31 5.2 203 107 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 744 850 956 59 24.8 0.77 18 1.34 5.3 209 111 24.1 0.73 19 1.33 5.3 207 110 22.2 0.70 19 1.29 5.1 201 106 Airflow MBh S/T ∆T kW 956 Amps Hi PR Lo PR MBh S/T ∆T kW 850 Amps Hi PR Lo PR MBh S/T ∆T 744 kW Amps Hi PR Lo PR 25.9 0.78 19 1.38 5.5 227 119 25.2 0.74 20 1.37 5.4 225 118 23.3 0.72 21 1.34 5.
SS-DSZC18 www.goodmanmfg.com 26.1 1.00 25 1.38 5.5 215 114 25.3 0.95 26 1.36 5.4 213 113 23.4 0.92 26.6 1.33 5.3 207 109 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 744 850 956 59 25.7 0.95 24 1.36 5.4 213 113 24.9 0.91 25 1.35 5.4 211 112 23.0 0.88 25 1.32 5.2 205 108 Airflow MBh S/T ∆T kW 956 Amps Hi PR Lo PR MBh S/T ∆T kW 850 Amps Hi PR Lo PR MBh S/T ∆T 744 kW Amps Hi PR Lo PR 26.6 0.97 25 1.41 5.6 232 121 25.8 0.92 26 1.39 5.5 229 120 23.8 0.
www.goodmanmfg.com 35.1 0.86 20 2.11 7.8 221 108 34.1 0.82 21 2.10 7.8 219 107 31.5 0.79 21 2.04 7.5 212 104 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 1094 1250 1406 59 34.5 0.76 17 2.10 7.8 219 107 33.5 0.72 18 2.08 7.7 217 106 30.9 0.70 18 2.03 7.5 210 103 Airflow MBh S/T ∆T kW 1406 Amps Hi PR Lo PR MBh S/T ∆T kW 1250 Amps Hi PR Lo PR MBh S/T ∆T 1094 kW Amps Hi PR Lo PR 36.1 0.77 18 2.16 8.0 238 115 35.1 0.74 19 2.14 8.0 235 114 32.4 0.71 19 2.
SS-DSZC18 www.goodmanmfg.com 36.4 0.99 24 2.15 8.0 225 110 35.3 0.95 25 2.13 7.9 223 109 32.6 0.91 25 2.08 7.7 216 106 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 1094 1250 1406 59 35.7 0.95 22 2.13 7.9 223 109 34.7 0.90 23 2.11 7.8 221 108 32.0 0.87 23 2.06 7.6 214 105 Airflow MBh S/T ∆T kW 1406 Amps Hi PR Lo PR MBh S/T ∆T kW 1250 Amps Hi PR Lo PR MBh S/T ∆T 1094 kW Amps Hi PR Lo PR 37.1 0.96 23 2.20 8.2 243 117 36.0 0.91 24 2.18 8.1 240 116 33.2 0.
www.goodmanmfg.com 35.6 0.86 21 1.87 0.1 211 111 34.6 0.82 22 1.85 0.1 209 110 31.9 0.79 22 1.80 0.1 203 107 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 1050 1200 1350 59 35.0 0.76 18 1.85 0.1 209 110 34.0 0.72 19 1.84 0.1 207 109 31.4 0.70 19 1.79 0.1 200 106 Airflow MBh S/T ∆T kW 1350 Amps Hi PR Lo PR MBh S/T ∆T kW 1200 Amps Hi PR Lo PR MBh S/T ∆T 1050 kW Amps Hi PR Lo PR 36.7 0.77 19 1.91 0.1 227 118 35.6 0.73 20 1.89 0.1 225 117 32.9 0.71 20 1.
SS-DSZC18 www.goodmanmfg.com 36.9 0.99 25 1.90 0.1 215 113 35.8 0.94 26 1.88 0.1 213 112 33.1 0.91 26.3 1.84 0.1 207 109 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 1050 1200 1350 59 36.3 0.94 23 1.88 0.1 213 112 35.2 0.90 24 1.87 0.1 211 111 32.5 0.87 25 1.82 0.1 205 108 Airflow MBh S/T ∆T kW 1350 Amps Hi PR Lo PR MBh S/T ∆T kW 1200 Amps Hi PR Lo PR MBh S/T ∆T 1050 kW Amps Hi PR Lo PR 37.6 0.95 24 1.94 0.1 231 120 36.5 0.91 25 1.93 0.1 229 119 33.
www.goodmanmfg.com 49.8 0.86 20 2.90 10.4 217 107 48.4 0.82 21 2.88 10.3 215 106 44.7 0.79 21 2.81 10.0 208 103 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 1531 1750 1969 59 49.0 0.75 17 2.88 10.3 214 106 47.6 0.72 18 2.85 10.2 212 105 43.9 0.69 18 2.78 9.9 206 102 Airflow MBh S/T ∆T kW 1969 Amps Hi PR Lo PR MBh S/T ∆T kW 1750 Amps Hi PR Lo PR MBh S/T ∆T 1531 kW Amps Hi PR Lo PR 51.3 0.77 18 2.96 10.7 233 114 49.8 0.73 19 2.94 10.6 231 113 46.0 0.
SS-DSZC18 www.goodmanmfg.com 51.6 0.99 24 2.95 10.6 221 109 50.1 0.94 25 2.93 10.5 219 108 46.2 0.91 25 2.85 10.2 212 105 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 1531 1750 1969 59 50.7 0.94 22 2.93 10.5 219 108 49.2 0.90 23 2.90 10.4 217 107 45.4 0.86 24 2.83 10.1 210 104 Airflow MBh S/T ∆T kW 1969 Amps Hi PR Lo PR MBh S/T ∆T kW 1750 Amps Hi PR Lo PR MBh S/T ∆T 1531 kW Amps Hi PR Lo PR 52.6 0.95 23 3.01 10.9 238 116 51.1 0.91 24 2.99 10.
www.goodmanmfg.com 42.3 0.81 23 2.37 9.2 211 106 41.1 0.77 24 2.35 9.1 209 105 37.9 0.74 25 2.29 8.9 202 102 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 1050 1200 1350 59 41.6 0.71 20 2.35 9.1 209 105 40.4 0.68 21 2.33 9.1 207 104 37.3 0.65 21 2.27 8.8 200 101 Airflow MBh S/T ∆T kW 1350 Amps Hi PR Lo PR MBh S/T ∆T kW 1200 Amps Hi PR Lo PR MBh S/T ∆T 1050 kW Amps Hi PR Lo PR 43.5 0.72 21 2.43 9.5 227 113 42.3 0.69 22 2.41 9.4 225 112 39.0 0.
SS-DSZC18 www.goodmanmfg.com 43.8 0.93 28 2.42 9.4 215 108 42.5 0.89 29 2.39 9.3 213 107 39.2 0.86 29.4 2.33 9.1 207 104 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 1050 1200 1350 59 43.0 0.89 26 2.39 9.3 213 107 41.8 0.85 27 2.37 9.2 211 106 38.6 0.82 28 2.31 9.0 204 103 Airflow MBh S/T ∆T kW 1350 Amps Hi PR Lo PR MBh S/T ∆T kW 1200 Amps Hi PR Lo PR MBh S/T ∆T 1050 kW Amps Hi PR Lo PR 44.6 0.90 27 2.47 9.6 231 115 43.3 0.86 28 2.45 9.5 229 114 40.
www.goodmanmfg.com 56.3 0.82 22 3.62 7.3 221 102 54.7 0.78 22 3.59 7.2 218 101 50.5 0.76 23 3.50 6.8 212 98 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 1531 1750 1969 59 55.4 0.72 19 3.59 7.2 218 101 53.8 0.69 19 3.56 7.1 216 100 49.6 0.66 20 3.47 6.7 210 97 Airflow MBh S/T ∆T kW 1969 Amps Hi PR Lo PR MBh S/T ∆T kW 1750 Amps Hi PR Lo PR MBh S/T ∆T 1531 kW Amps Hi PR Lo PR 58.0 0.73 20 3.71 7.7 237 108 56.3 0.70 21 3.67 7.5 235 107 51.9 0.68 21 3.
SS-DSZC18 www.goodmanmfg.com 58.3 0.94 26 3.69 7.6 225 104 56.6 0.90 27 3.65 7.4 223 103 52.2 0.87 27 3.56 7.1 216 100 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 1531 1750 1969 59 57.3 0.90 24 3.65 7.4 223 103 55.6 0.86 25 3.62 7.3 221 102 51.4 0.83 26 3.53 6.9 214 99 Airflow MBh S/T ∆T kW 1969 Amps Hi PR Lo PR MBh S/T ∆T kW 1750 Amps Hi PR Lo PR MBh S/T ∆T 1531 kW Amps Hi PR Lo PR 59.4 0.91 25 3.77 7.9 242 111 57.7 0.87 26 3.74 7.8 240 109 53.3 0.
www.goodmanmfg.com 40.7 0.83 23 2.24 8.0 208 109 39.5 0.79 24 2.23 7.9 206 107 36.5 0.77 24 2.17 7.7 200 104 MBh S/T DT kW Amps Hi PR Lo PR MBh S/T DT kW Amps Hi PR Lo PR MBh S/T DT kW Amps Hi PR Lo PR 1050 1200 1350 59 40.0 0.73 20 2.22 7.9 206 107 38.9 0.70 21 2.21 7.8 204 106 35.9 0.67 21 2.15 7.6 198 103 Airflow MBh S/T DT kW 1350 Amps Hi PR Lo PR MBh S/T DT kW 1200 Amps Hi PR Lo PR MBh S/T DT 1050 kW Amps Hi PR Lo PR 41.9 0.75 21 2.29 8.1 224 115 40.7 0.71 22 2.28 8.1 222 114 37.6 0.
SS-DSZC18 www.goodmanmfg.com 42.2 0.96 28 2.28 8.1 212 111 40.9 0.91 29 2.26 8.0 210 110 37.8 0.88 29 2.21 7.8 204 106 MBh S/T DT kW Amps Hi PR Lo PR MBh S/T DT kW Amps Hi PR Lo PR MBh S/T DT kW Amps Hi PR Lo PR 1050 1200 1350 59 41.4 0.91 26 2.26 8.0 210 110 40.2 0.87 27 2.24 8.0 208 109 37.1 0.84 27 2.19 7.7 202 105 Airflow MBh S/T DT kW 1350 Amps Hi PR Lo PR MBh S/T DT kW 1200 Amps Hi PR Lo PR MBh S/T DT 1050 kW Amps Hi PR Lo PR 43.0 0.92 27 2.33 8.3 229 118 41.7 0.88 28 2.31 8.2 226 117 38.5 0.
www.goodmanmfg.com 55.5 0.83 21 3.51 13.1 209 108 54.7 0.80 22 3.49 13.0 207 107 51.9 0.76 23 3.43 12.8 203 105 MBh S/T DT kW Amps Hi PR Lo PR MBh S/T DT kW Amps Hi PR Lo PR MBh S/T DT kW Amps Hi PR Lo PR 1600 1800 2000 59 54.6 0.73 18 3.48 13.0 206 106 53.8 0.70 19 3.46 12.9 205 106 51.1 0.67 20 3.41 12.7 201 104 Airflow MBh S/T DT kW 2000 Amps Hi PR Lo PR MBh S/T DT kW 1800 Amps Hi PR Lo PR MBh S/T DT 1600 kW Amps Hi PR Lo PR 57.1 0.75 20 3.58 13.4 224 114 56.3 0.71 21 3.56 13.4 223 114 53.
SS-DSZC18 www.goodmanmfg.com 57.5 0.96 25 3.56 13.4 213 110 56.6 0.92 27 3.55 13.3 211 109 53.8 0.88 27 3.49 13.0 207 107 MBh S/T DT kW Amps Hi PR Lo PR MBh S/T DT kW Amps Hi PR Lo PR MBh S/T DT kW Amps Hi PR Lo PR 1600 1800 2000 59 56.5 0.91 24 3.54 13.2 211 109 55.6 0.88 25 3.52 13.2 209 108 52.9 0.84 25 3.46 12.9 205 106 Airflow MBh S/T DT kW 2000 Amps Hi PR Lo PR MBh S/T DT kW 1800 Amps Hi PR Lo PR MBh S/T DT 1600 kW Amps Hi PR Lo PR 58.6 0.92 25 3.64 13.7 229 117 57.7 0.89 26 3.62 13.
Product Specifications Expanded Heating Data DSZC180361A* / CA*F3642C6A*+TXV/ MBE1600**-1 — High Stage Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 44.5 42.2 39.7 37.1 35.4 34.3 31.9 29.4 27.5 25.4 23.4 22.0 21.2 19.1 16.9 14.7 12.6 10.3 ∆T 33.0 31.2 29.4 27.5 26.2 25.4 23.6 21.8 20.4 18.8 17.3 16.3 15.7 14.1 12.5 10.9 9.3 7.6 kW 2.81 2.75 2.69 2.63 2.6 2.57 2.52 2.46 2.43 2.37 2.32 2.28 2.26 2.
Product Specifications Expanded Heating Data (cont.) DSZC180601A* /CA*F4860*6A*+TXV/ MBE2000**-1 — High Stage Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 71.6 67.8 63.8 59.7 57.0 55.2 51.3 47.3 46.7 43.1 39.7 37.5 36.1 32.4 28.7 25.0 21.4 17.5 ∆T 37.9 35.9 33.8 31.6 30.2 29.2 27.1 25.0 24.7 22.8 21.0 19.8 19.1 17.1 15.2 13.2 11.3 9.3 kW 4.94 4.84 4.73 4.63 4.6 4.52 4.42 4.32 4.28 4.17 4.07 4.00 3.
Product Specifications AHRI Ratings Outdoor Unit DSZC18 0361A* Indoor Units Coil/Air Handler Furnace/Blower Cooling Capacity (BTU/h) TVA Ratings³ Heating Capacity (BTU/h) AHRI # Total Sens. EER² SEER¹ Total Sens. High HSPF⁴ Low AEPF313716A*+TXV AEPF426016C*+TXV 35,000 35,000 26,600 26,600 13.0 13.0 18.0 18.0 32,600 32,600 26,400 26,400 35,000 35,000 9.3 9.3 20,400 20,400 3654730 3654731 AVPTC313714A* 35,000 26,600 13.0 18.0 32,600 26,400 35,000 9.
Product Specifications AHRI Ratings (cont.) Outdoor Unit DSZC18 0361A* (cont.) Indoor Units Coil/Air Handler Furnace/Blower Cooling Capacity (BTU/h) TVA Ratings³ Heating Capacity (BTU/h) Total Sens. EER² SEER¹ Total Sens. High HSPF⁴ Low AHRI # CA*F3743*6D*+TXV CA*F3743*6D*+TXV A*VC80704BXA* MBVC1600**-1A* 34,600 35,000 26,300 26,600 12.5 13.0 17.5 18.0 32,200 32,600 26,100 26,400 35,000 35,000 9.3 9.
Product Specifications AHRI Ratings (cont.) Outdoor Unit DSZC18 0361A* (cont.) Indoor Units Coil/Air Handler Furnace/Blower Cooling Capacity (BTU/h) TVA Ratings³ Heating Capacity (BTU/h) Total Sens. EER² SEER¹ Total Sens. High HSPF⁴ Low AHRI # CA*F4961*6D*+TXV CA*F4961*6D*+TXV G*VC950714CXA* G*VC950704CXA* 34,600 34,600 26,300 26,300 12.5 12.5 17.5 17.5 32,200 32,200 26,100 26,100 35,000 35,000 9.3 9.
Product Specifications AHRI Ratings (cont.) Outdoor Unit DSZC18 0361A* (cont.) Indoor Units Coil/Air Handler Furnace/Blower Cooling Capacity (BTU/h) TVA Ratings³ Heating Capacity (BTU/h) Total Sens. EER² SEER¹ Total Sens. High HSPF⁴ Low AHRI # CHPF4860D6D*+TXV CHPF4860D6D*+TXV G*VC950915DXA* G*VC950714CXA* 35,000 34,600 26,600 26,300 12.8 12.5 18.0 17.5 32,600 32,200 26,400 26,100 35,000 35,000 9.3 9.
Product Specifications AHRI Ratings (cont.) Outdoor Unit DSZC18 0361A* (cont.) DSZC18 0481A* Indoor Units Coil/Air Handler Furnace/Blower Cooling Capacity (BTU/h) TVA Ratings³ Heating Capacity (BTU/h) Total Sens. EER² SEER¹ Total Sens. High HSPF⁴ Low AHRI # CSCF4860N6C*+TXV CSCF4860N6C*+TXV G*VC950905CXA* G*VC950915DXA* 35,000 35,000 26,600 26,600 12.5 12.8 17.5 18.0 32,600 32,600 26,400 26,400 35,000 35,000 9.3 9.
Product Specifications AHRI Ratings (cont.) Outdoor Unit DSZC18 0481A* (cont.) Indoor Units Coil/Air Handler Furnace/Blower Cooling Capacity (BTU/h) Total Sens. EER² SEER¹ TVA Ratings³ Total Sens. Heating Capacity (BTU/h) High HSPF⁴ Low AHRI # CA*F4961*6A*+TXV CA*F4961*6A*+TXV A*V81155C** A*V80905C** 47,000 47,000 35,300 35,300 12.5 12.5 17.5 17.5 43,700 43,700 33,600 33,600 47,000 47,000 9.3 9.3 29,000 29,000 3654886 3654885 CA*F4961*6A*+TXV MBVC2000**-1* 47,500 35,600 13.0 18.
Product Specifications AHRI Ratings (cont.) Outdoor Unit Indoor Units Coil/Air Handler Furnace/Blower AEPF426016C*+TXV DSZC18 0601A* Cooling Capacity (BTU/h) TVA Ratings³ Heating Capacity (BTU/h) Total Sens. EER² SEER¹ Total Sens. High HSPF⁴ Low AHRI # 56,000 40,300 12.5 16.0 52,100 40,100 56,000 9.0 35,000 3654928 CA*F4961*6A*+TXV A*VC950915DXA* 57,000 41,000 12.0 16.0 53,000 40,800 57,000 9.3 35,000 4594736 CA*F4961*6A*+TXV G*VC950905CXA* 57,000 41,000 11.
Product Specifications AHRI Ratings (cont.) Outdoor Unit Indoor Units Coil/Air Handler Furnace/Blower AEPF426016C*+TXV AVPTC426014A* DSZC18 0601B* Cooling Capacity (BTU/h) TVA Ratings³ Heating Capacity (BTU/h) AHRI # Total Sens. EER² SEER¹ Total Sens. High HSPF⁴ Low 56,000 56,000 40,300 40,300 12.5 12.5 17.0 17.0 52,100 52,100 40,100 40,100 56,000 56,000 9.5 9.5 34,600 34,600 4236537 4431330 CA*F4961*6A*+TXV G*VC950915DXA* 55,500 40,000 12.2 16.7 51,600 39,700 56,000 9.
Product Specifications Dimensions Model Dimensions W" D" H" DSZC180361A 35½ 35½ 38¼ DSZC180481A 35½ 35½ 38¼ DSZC180601A 35½ 35½ 38¼ DSZC180601B 35½ 35½ 38¼ See Notes on Page 26. 30 www.goodmanmfg.
YL YL BK C Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. NOTE: 1. USE COPPER SUPPLY WIRES ONLY. 2. USE 40VA TRANSFORMER MINIMUM FOR SYSTEM 3. IF DT IS NOT PRESENT, HPS BL/PK WIRE GOES DIRECTLY TO TERMINAL E29. 4. CONTROLS SHOWN WITH THERMOSTAT IN "OFF" POSITION. 5. COMMON SIDE OF 24VAC CONTROL CIRCUIT MUST BE GROUNDED.
Product Specifications Accessories Model Description ABK-20 Anchor Bracket Kit◊ B1141643¹ CSR-U-1 CSR-U-2 CSR-U-3 FSK01A² OT18-60A³ TX2N4⁴ TX2N4A⁴ TX3N4⁴ TX5N4⁴ 24V Transformer Hard-start Kit Hard-start Kit Hard-start Kit Freeze Protection Kit Outdoor Thermostat/Lockout Thermostat TXV Kit TXV Kit TXV Kit TXV Kit ◊ ¹ ² ³ DSZC18 036 DSZC18 048 DSZC18 060 X X X X X X X X X X X X X X X X X X Contains 20 brackets; four brackets needed to anchor unit to pad Available in 24V legacy mode only.