AVPTC Installation Manual

13
Figure 19
Figure 20
2. Download the Cool Cloud HVAC phone application.
Note: When new versions of Bluetooth Communication
Software and Air Handler Control Software are available,
the phone application notifies the user. Software updates
are classified as either optional or mandatory and
installed by using the phone application. Ensure all
mandatory software updates have been installed. Review
notes for optional software updates and install if
necessary.
3. Go to the Non-Comm Outdoor Setting Menu () using
the on board push buttons or the Cool Cloud HVAC
phone application. Selec t “” for single stage Air
Conditioners, “” for single stage Heat Pumps, “
for two stage Air Conditioners and “” for 2 stage Heat
Pumps.
4. Go to the Tonnage Units Menu () and select the
tonnage value that corresponds to the desired airflow for
the outdoor unit. See the following table.
NOTE: For the two stage non-communicating outdoor
units, system will stage airflow automatically for low
stage operation.
NOTE: The system will not provide airflows above the max Airflow
Value.
Model MAX CFM
AVPTC25B14
AVPTC29B14
AVPTC35B14
AVPTC37B14
1200
AVPTC33C14 1300
AVPTC31C14
AVPTC37C14
AVPTC39C14
1600
AVPTC37D14
AVPTC49C14
1800
AVPTC49D14
AVPTC59C14
1900
AVPTC59D14
AVPTC61D14
2100
5. Use the Cool Cloud HVAC phone application to configure/
test air handler operations.
NOTE: The phone application cannot test a non- communicating
outdoor unit. The thermostat will be required for outdoor unit
testing.
17.1 Electric Heater Kit Testing
1. Two-stage outdoor units:
a. Provide a second stage cooling call from the
thermostat and charge accordingly.
2. Single-stage outdoor units:
a. Provide a cooling call from the thermostat and
charge accordingly.