AVPTC Installation Manual
22
28 Air Handler Label
0140A00615-A
Airflow Settings Instructions
1) For non-communicating installations, select the type of unit installed
in the
0d5
menu (
1AC
= single-stage air conditioner,
1HP
= single-stage heat pump,
2AC
= 2 stage air conditioner,
2HP
= 2 stage heat pump) Default =
OFF
(no outdoor unit).
2) Use the Tonnage Menu (
ton
) to select Cooling/Heat Pump Airflow
(non-communicating installation). Tonnage selection options and
correspo
nding airflow CFM can be found to the right.
[Airflow = Tonnage Selection x 400] Default selection is 6.0 tons.
3)
[Optional] Use the Cooling Trim Menu (
CtF
) to adjust the cooling
airflow
from -10% to +10% (2% increments).
This applies for 2
stage communicating outdoor units and single or 2 stage
non-communicating ou
tdoor units (2 stage
non-communicating
outdoor units require an equipment relay board to function with this
system). For inverter
outdoor units use Cooling Trim
Factor High,
Intermediate and L
ow menus(
CtH
,
Ct
, and CtL) for trim
adjustment.
4) [Optional] Use the Heating Trim Menu(HtF) to adjust the heat pump
airflow
from -10% to +10% (2% increments).
This applies for 2
stage communicating outdoor units and single or 2 stage
non-communicating ou
tdoor units (all non-communicating outdoor
units require an equipment r
elay board for the trim option to be
available). For inver
ter outdoor units use Heating Trim Factor High,
Intermediate and L
ow menus (
HtH
,
Ht1
,and
HtL
) for trim
adjustment.
5) [Optional]
Use the Constant Fan Menu (
F5d
) to select the
percentage of maximum airflow for continuous fan
6) [Optional] Use the Cooling Airflow Profile Menu (
CAP
) to select
between 5 cooling airflow profiles. Profile options 1-4 are listed above
(option 5 is adjustable). See installation manual for further details
Profiles
Pre-Run Short-Run OFF Delay
1 -------- -------- 60 sec/100%
2 -------- 30 sec/50% 60 sec/100%
3 -------- 7.5 min/82% 60 sec/100%
4 30 sec/50% 7.5 min/82% 60 sec/100%
Selecting Heater Kit: Use the Electric Heating Wattage Menu (
EHt
) to select heater kit size. See "Menu Navigation and Selection Instructions"
above. Default selection is 0 (No Heat Kit). Select installed heater kit for heater kit operation.
NR - Not Rated
++ For match up with a 3 ton outdoor unit: Airflow for 5kW up to 15kW heater kits shall be set to 1220 CFM by selecting 10 in the
Electric Heating Wattage (
EHt
) menu.
+++ For match up with a 3.5 ton outdoor unit: Heater kit application shall not exceed 20 kW. Airflow for 5kW up to 20kW heater kits
shall be set to 1320 CFM by selecting 10 in theElectric Heating Wattage (
EHt
) menu.
Electric Heat Airflow Table
Menu Navigation and Selection Instructions
Using Phone Application over Bluetooth Network:
1) Connect to the air handler (instructions provided by phone during
connection process).
2)
Select desired settings menu
3) Select item that requires adjustment and m
ake necessary selection
4) Submit Changes
Using On-Board Push Buttons:
1) Use the Right and Left Buttons to scroll between menus
2) Use the Center Button to select desired menu when menu code is
shown on 7-segment displays
3) Use the Left and Right Buttons to scroll through options within the
desired menu (the display will flash while scrolling through options for
selection)
4)
Use the Center Button to select the displayed option (when selected
the display will stop flashing
)
5) Use the Center Button to finalize selection and return to the main
menu
*If
airflow is set above the model's maximum value, the output will be the
maximum value
Maximum Airflow Output
Tonnage
Selection
Airflow
1.0 400
1.1 440
1.2 480
1.3 520
1.4 560
1.5 600
1.6 640
1.7 680
1.8 720
1.9 760
2.0 800
2.1 840
2.2 880
2.3 920
2.4 960
2.5 1000
2.6 1040
2.7 1080
2.8 1120
2.9 1160
3.0 1200
3.1 1240
3.2 1280
3.3 1320
3.4 1360
3.5 1400
Tonnage Menu (t o n)
Tonnage
Selection
Airflow
3.5 1400
3.6 1440
3.7 1480
3.8 1520
3.9 1560
4.0 1600
4.1 1640
4.2 1680
4.3 1720
4.4 1760
4.5 1800
4.6 1840
4.7 1880
4.8 1920
4.9 1960
5.0 2000
5.1 2040
5.2 2080
5.3 2120
5.4 2160
5.5 2200
5.6 2240
5.7 2280
5.8 2320
5.9 2360
6.0 2400
AVPTC2 5B14
AVPTC2 9B14
AVPTC3 5B14
AVPTC3 7B14
AVPTC33C14
AVPTC3 1C14
AVPTC3 7C14
AVPTC3 9C14
AVPTC37D14
AVPTC49C14
AVPTC49D14
AVPTC59C14
AVPTC5 9D14
AVPTC6 1D14
12001300 1600 1800 1900 2100
1
Htr Kw
3
5
6
19
15
10
8
25
21
20
AVPTC25B14 AVPTC29B14
550
650
700
800
850
NR
NR
NR
NR
875
550
650
700
800
875
NR
NR
NR
NR
875
550
650
700
800
875
NR
NR
NR
NR
1050
600
700
770
880
1090
NR
NR
NR
1280
600
700
750
850
920
NR
NR
NR
NR
950
AVPTC29B14
AVPTC29B14
AVPTC31C14 AVPTC31C14
970
NR
700
770
880
970
NR
NR
NR
1280
1090
AVPTC37C14
AVPTC39C14
NR
800
800
950
1090
NR
NR
NR
1290
AVPTC49C14
AVPTC59C14
870
970
1060
1120
NR
NR
1250
1220
AVPTC37D14
950
1060
1150
1220
NR
NR
NR
NR
1520
AVPTC49D14
++
990
1110
1200
1240
NR
NR
NR
1520
AVPTC59D14
1030
NR
NR
AVPTC61D14
++
1345
NR
NR
NR NR
NR
1150
1250
1320
1650
1690
1750
1520