Installation Guide

19
CIRCULATION AIR FILTERS
Figure 11 Figure 12
Figure 13 Figure 14
Figure 15
One of the most common causes of a problem in a forced
air heating system is a blocked or dirty fi lter. Circulating air
lters must be inspected monthly for dirt accumulation and
replaced if necessary. Failure to maintain clean lters can
cause premature heat exchanger failure.
A new home may require more frequent replacement until all
construction dust and dirt is removed.
Upflow / Horizontal
Models
Minimum Recommended Filter Size^
*MEC80403B* 1 - 16 X 25 Side or 1 - 14 X 24 Bottom Return
*MEC80603B* 1 - 16 X 25 Side or 1 - 14 X 24 Bottom Return
*MEC80604B* 1 - 16 X 25 Side or 14 X 24 Bottom Return
*MEC80803B* 1 - 16 X 25 Side or Bottom Return
*MEC80804C* 1 - 16 X 25 Side or Bottom Return
*MEC80805C*¹ 1 - 16 X 25 Side or Bottom Return¹
*MEC80805D*¹ 1 - 16 X 25 Side or Bottom Return¹
*MEC81005C* 2 - 16 X 25 Side or 1 - 20 X 25 Bottom Return
*MEC81005C* 2 - 16 X 25 Side or 1 - 20 X 25 Bottom Return
Downflow / Horizontal
Models
*CEC80403B* 2 - 10 X 20 or 1 - 14 X 25 Top Return
*CEC80603B* 2 - 10 X 20 or 1 - 14 X 25 Top Return
*CEC80805C* 2 - 14 X 20 or 1 - 16 X 25 Top Return
*CEC81005C* 2 - 14 X 20 or 1 - 20 X 25 Top Return
¹ = use 2 - 16 X 25 filters and two side returns or 20 X 25
filter on bottom return if furnace is connected
to a cooling unit over 4 tons nominal capacity
^ Larger filters may be used, filters may also be centrally located
ELECTRICAL
24 VOLT THERMOSTAT WIRING
WIRE ROUTING MUST NOT INTERFERE WITH CIRCULATOR BLOWER
OPERATION, FILTER REMOVAL OR ROUTINE MAINTENANCE.
IMPORTANT NOTE
Low voltage connections can be made through either the right or
left side panel. Thermostat wiring entrance holes are located in
the blower compartment. The following gure shows connections
for a “heat/cool system”.
This furnace is equipped with a 40 VA transformer to facilitate
use with most cooling equipment. Consult the wiring diagram,
located on the blower compartment door, for further details of
115 Volt and 24 Volt wiring.
R
Y C
Furnace
Integrated
Control
Module
Remot e Condensing Unit
(Single-Stage Cooling)
R
Thermostat - Single -Stage Heating with Single-Stage Cooling
NOTE: To apply a single-stage Heating Thermostat, the thermostat
selector switch on the Integrated Control Module must be set
on single-stage.