Installation Guide

28
AIRFLOW TABLES
GCEC800403AN
PCBBF139
STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM
Ylo 785 754 736 690 650 604 565 527
Y 1348 1294 1261 1250 1229 1233 1205 1182
Ylo 663 647 597 551 501 458 408 355
Y 785 754 736 690 650 604 565 527
Ylo 663 647 597 551 501 458 408 355
Y 1348 1294 1261 1250 1229 1233 1205 1182
Ylo 785 754 736 690 650 604 565 527
Y 591 568 518 463 411 355 300 243
Ylo 785 754 736 690 650 604 565 527
Y 1104 1058 1020 1022 1013 981 952 918
Ylo 663 647 597 551 501 458 408 355
Y 591 568 518 463 411 355 300 243
Ylo 1104 1058 1020 1022 1013 981 952 918
Y 1348 1294 1261 1250 1229 1233 1205 1182
Ylo 1104 1058 1020 1022 1013 981 952 918
Y 663 647 597 551 501 458 408 355
PCBBF139
STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM
OFF OFF OFF G 591 568 518 463 411 355 300 243
ON OFF OFF G 1104 1058 1020 1022 1013 981 952 918
ON ON OFF G 663 647 597 551 501 458 408 355
OFF ON OFF G 785 754 736 690 650 604 565 527
OFF OFF ON G 1348 1294 1261 1250 1229 1233 1205 1182
OFF ON ON G 591 568 518 463 411 355 300 243
ON OFF ON G 591 568 518 463 411 355 300 243
ON ON ON G 591 568 518 463 411 355 300 243
PCBBF139
STATIC 0.6 0.7 0.8
T STAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM
W1 591 35 568 37 518 40 463 45 411 N/A 355 300 243
W2 1104 27 1058 28 1020 29 1022 29 1013 29 981 952 918
W1 663 31 647 32 597 35 551 38 501 41 458 408 355
W2 1104 27 1058 28 1020 29 1022 29 1013 29 981 952 918
W1 663 31 647 32 597 35 551 38 501 41 458 408 355
W2 785 38 754 39 736 40 690 43 650 N/A 604 565 527
W1 785 26 754 28 736 28 690 30 650 32 604 565 527
W2 1348 22 1294 23 1261 23 1250 24 1229 24 1233 1205 1182
0.4
0.5
OFF OFF*
ON OFF
ON ON
**NOT RECOMMENDED
DIP Switches
S1-4 S2-1
0.1
0.2
0.3
OFF ON
*DEFAULT
*CEC800403A* - HEATING
DIP Switches
S2-2 S2-3 S2-4
*CEC800403A* - COOLING
DIP Switches
S1-1 S1-2 S1-3
OFF OFF OFF*
ON OFF OFF
ON ON OFF
OFF ON OFF
OFF OFF ON
OFF ON ON
ON OFF ON
ON ON ON
*CEC800403A* - CONTINOUS FAN