Service Manual

PRODUCT IDENTIFICATION
9
MODEL # MFG # DESCRIPTION
CTK02**
CTK02**
Communicating Thermostat Kit-
Digitally communicating thermostat. Designed for
use with compatible Amana® Brand or Goodman® Brand Air Handlers or Furnaces
and outdoor split AC or Heat Pump units. The CTK02** thermostat features a full color
high definition display, advanced programming options including humidification control
& heat and cool maximum temperature settings, a USB plug allowing dealers the
ability to insert pre-programmed operating parameters and dealer information by use
of an online data entry system.
CTK03AA
CTK03AA
Communicating Thermostat Kit-
Digitally communicating touchscreen thermostat
from Honeywell. Designed for use with compatible Amana® Brand or Goodman®
Brand Air Handlers or Furnaces and outdoor split AC or Heat Pump units. The
CTK03AA thermostat features full color high definition display and can be used with
RedLINK wireless accessories.
CTK03AB
CTK03AB
Communicating Thermostat Kit-
Digitally communicating touchscreen thermostat
from Honeywell. Designed for use with compatible Amana® Brand or Goodman®
Brand Air Handlers or Furnaces and outdoor split AC or Heat Pump units. The
CTK03AB thermostat features full color high definition display and can be used with
RedLINK wireless accessories and added capabilty to control the HUM IN - HUM OUT
relay.
CTK04
CTK04AA
Communicating Thermostat Kit-
Digitally communicating touchscreen thermostat
from Honeywell. Designed for use with compatible Amana® Brand or Goodman®
Brand Air Handlers or Furnaces and outdoor split AC or Heat Pump units. The CTK04
thermostat features full color high definition display and can be used with RedLINK
wireless accessories and added capabilty to control the HUM IN - HUM OUT relay. Split
system inverter capable.
DCVK-20
(CVENT-2)
DCVK-30
(CVENT-3)
N/A
Concentric Vent Kit.
For use with Amana® Brand 90% furnace models. This kit is
designed to allow terminations of a direct vent furnace to be "concentrically" vented
through a wall or roof. This kit allows a single penetration to support terminations for
both the vent/flue and the combustion air intake pipe. The DCVK-20 (2") and DCVK-30
(3") kits are certified for models listed above. See specification sheets on future
models for use of the vent kit.
0170K00000S
N/A
Side Wall Only Concentric Vent Kit
. For use with 90% furnace models. This kit is to be
used with 2" - 3" vent systems. The vent kit must terminate outside the structure. This
kit is NOT intended for use with single pipe (indirect vent) installations.
0170K00001S
N/A
Side Wall Only Concentric Vent Kit
. For use with 90% furnace models. This kit is to be
used only with 2" vent systems. The vent kit must terminate outside the structure. This
kit is NOT intended for use with single pipe (indirect vent) installations.
DEHUM1
P1227801F
Dehumidistat.
For use with Goodman® and Amana® Brand two-stage variable speed
furnace models. Wall mounted, 24 volt humidity control available as a Dehumidistat
used to reduce the airflow in the air conditioning mode when necessary to lower the
humidity in an occupied home to prevent dew build-up associated with high humidity
levels. This control features a moisture-sensitive nylon element and also provides
positive ON-OFF settings for manual operation. The control is a normally closed switch
that opens on humidity rise causing the blower to switch to a lower speed to control the
humidity within the structure.