PRODUCT IDENTIFICATION
9
MODEL # MFG # DESCRIPTION
AFE18-60A
N/A
Fossil Fuel Kit.
The AFE18-60A control is designed for use where the indoor coil is located
above/downstream of a gas or fossil fuel furnace when used with a heat pump. It will operate
with single and two stage heat pumps and single and two stage furnaces. The AFE18-60A
control will turn the heat pump unit off when the furnace is turned on. An anti-short cycle
feature initiates a 3 minute timed off delay when the compressor goes off.
AMU1620
AMU1625
AMU2020
AMU2025
GMU1 62 0
GMU1 62 5
GMU2 02 0
GMU2 02 5
P1251305F
P1251306F
P1251307F
P1251308F
N/A
Media Air Cleaner.
For use with current architectural grey Goodman® and Amana® Brand
furnace models. The Amana (AMU*) and Goodman (GMU*) Media Air Cleaner is a high
efficiency air filtration device designed to remove dirt, dust, pollen and other microscopic
particles from the air passing through it. Flexible performance range up to 2,000 CFM capacity.
The air cleaner should be installed in the system so that all the system air is circulated
through the air cleaner. The air cleaner will only remove the airborne contaminants delivered
to it. Maximum performance is obtained when the system blower is set for continuous
operation. Carbon filters (optional) are available.
ASAS-10
ASAS-11
ASAS-12
ASAS-18
P1251301F
P1251302F
P1251303F
P1251304F
Electronic Air Cleaner.
For use with current architectural grey Goodman® and Amana® Brand
furnace models. The High-Efficiency Electronic Air Cleaner is designed to remove air
contaminants down to .01 microns. Carbon filters (optional) remove odors. Dual indicator
lights show unit operation at a glance. Electronic proving switch cycles the air cleaner On/Off
with the system fan. Durable powder-coat paint finish resists corrosion.
CFSB17
CFSB21
CFSB24
N/A
Counterflow Subbase Kit.
For use with select Goodman® and Amana® Brand 34.5" furnace
models ACVC9 and GCVC9. These kits are available for the following furnace widths: 17.5"
wide (CFSB17), 21" wide (CFSB21) and 24" wide (CFSB24). The kits must be used to prevent
excessive temperature from reaching combustible materials, if the furnace is installed on a
combustible floor. This subbase effectively separated the furnace base and plenum from
combustible materials. To ensure safe installation, do not install the counterflow floor base
directly on carpeting, tile, or other combustible material other than wood flooring.
CTK01AA
CTK01A A
Communicating Thermostat Kit-
Digitally communicating touchscreen thermostat. Designed
for use with compatible Amana® Brand or Goodman® Brand Air Handlers or Furnaces and
outdoor split AC or Heat Pump units. This thermostat supports up to three stages of heat, two
stages of cooling, dual fuel applications, dehumidification, filter maintenance reminders,
outdoor temperature display and advanced menus including diagnostics. The CTK01AA kit
includes a communicating touchscreen thermostat and sub base, 230V-24V 40va
transformer, terminal blocks(2), wire jumpers, mounting screws, installation manual and
homeowner guide.
CTK01BA
CTK01BA
Communicating Thermostat Kit-
Digitally communicating touchscreen thermostat. Designed
for use with compatible Amana® Brand or Goodman® Brand Air Handlers or Furnaces and
outdoor split AC or Heat Pump units. This thermostat supports up to three stages of heat, two
stages of cooling, dual fuel applications, dehumidification, filter maintenance reminders,
outdoor temperature display and advanced menus including diagnostics. The CTK01BA kit
includes a communicating touchscreen thermostat and sub base, terminal blocks(2),
installation manual and homeowner guide.