User Information

3
Dear Homeowner, please recognize the following safety in-
formation. This information will alert you to the potential for
personal injury.
WARNING - Indicate hazards or unsafe practices which
COULD result in severe personal injury or death.
T
HIS
PRODUCT
CONTAINS
OR
PRODUCES
A
CHEMICAL
OR
CHEMICALS
WHICH
MAY
CAUSE
SERIOUS
ILLNESS
OR
DEATH
AND
WHICH
ARE
KNOWN
TO
THE
S
TATE
OF
C
ALIFORNIA
TO
CAUSE
CANCER
,
BIRTH
DEFECTS
OR
OTHER
REPRODUCTIVE
HARM
.
WARNING
T
O
AVOID
POSSIBLE
EQUIPMENT
DAMAGE
,
PERSONAL
INJURY
,
FIRE
OR
DEATH
,
THE
FOLLOWING
INSTRUCTIONS
MUST
BE
OBSERVED
REGARDING
UNIT
LOCATION
,
AIR
REQUIREMENTS
AND
OPERATING
PROCEDURES
.
WARNING
H
EATING
UNIT
SHOULD
NOT
BE
UTILIZED
WITHOUT
REASONABLE
,
ROUTINE
,
INSPECTION
,
MAINTENANCE
AND
SUPERVISION
. I
F
THE
BUILDING
IN
WHICH
ANY
SUCH
DEVICE
IS
LOCATED
WILL
BE
VACANT
,
CARE
SHOULD
BE
TAKEN
THAT
SUCH
DEVICE
IS
ROUTINELY
INSPECTED
,
MAINTAINED
AND
MONITORED
.
IN
THE
EVENT
THAT
THE
BUILDING
MAYBE
EXPOSED
TO
FREEZING
TEMPERATURES
AND
WILL
BE
VACANT
,
ALL
WATER
-
BEARING
PIPES
SHOULD
BE
DRAINED
,
THE
BUILDING
SHOULD
BE
PROPERLY
WINTERIZED
,
AND
THE
WATER
SOURCE
CLOSED
.
IN
THE
EVENT
THAT
THE
BUILDING
MAY
BE
EXPOSED
TO
FREEZING
TEMPERATURES
AND
WILL
BE
VACANT
,
ANY
HYDRONIC
COIL
UNITS
SHOULD
BE
DRAINED
AS
WELL
AND
,
IN
SUCH
CASE
,
ALTERNATIVE
HEAT
SOURCES
SHOULD
BE
UTILIZED
.
WARNING
IMPORTANT NOTE TO THE OWNER REGARDING PRODUCT
LIMITED WARRANTY
Your limited warranty certificate is supplied as a separate
document with the unit installed by your contractor. Read
the limited warranty certificate carefully to determine what is
and is not covered and keep the warranty certificate in a
safe place. If you are unable to locate the warranty certifi-
cate please contact your installing contractor or contact cus-
tomer service (877-254-4729) to obtain a copy.
Before using this manual, check the serial plate for proper
model identification.
The installation and servicing of this equipment must be
performed by qualified, experienced technicians only.
UNIT LOCATION
1. The furnace area and the vicinity of any other gas appli-
ances must be kept clear and free of combustible materi-
als, gasoline, and other flammable vapors and liquids.
Also, do not store or use flammable items such as paint,
varnish, or lacquer in the area.
2. Do not store or use chlorine or fluorine products (bleaches,
cements, strippers, aerosols) near the unit. They can cor-
rode the heat exchanger.
3. Do not use the furnace closet as storage for brooms,
mops, brushes and oily rags or cloths. The area must be
kept clear, clean and free of lint. Furnace must be kept
free and clear of exposed or loose insulation materials in
the area of installation. Examine the furnace area when
the furnace or additional insulation is added since some
insulation materials may be combustible.
4. Make sure the furnace is always connected to an ap-
proved vent, in good condition, to carry combustion prod-
ucts outdoors.
5. Familiarize yourself with the controls that shut off the gas
and electrical power to the furnace. If the furnace is to be
shut down at the end of the heating season, turn off both
the gas and electrical power. For safety, always turn the
gas and electrical power off before performing service or
maintenance on the furnace.
6. Establish a regular maintenance schedule to insure effi-
cient and safe operation of the furnace. The furnace
should be checked at the beginning of each heating and
cooling season by a qualified service technician.
T
O
AVOID
PERSONAL
INJURY
OR
FIRE
,
MINIMUM
CLEARANCES
TO
COMBUSTIBLE
SURFACES
MUST
BE
FOLLOWED
.
WARNING
7. Make certain the required clearances for the furnace are
always maintained. These clearances are listed on the
furnace clearance label. If any question develops, con-
tact the installer of the furnace or another qualified ser-
vicer.
UNIT INSTALLATION
Examine the furnace installation to determine the following:
1. All flue product carrying passages external to the furnace
(i.e. chimney, vent connector) are clear and free of ob-
structions.
2. The vent connector is in place, slopes upward and is
physically sound without holes or excessive corrosion.
3. The return air duct connection is physically sound, sealed
to the furnace casing, and terminates outside the space
containing the furnace.
4. The physical support of the furnace is sound without sag-
ging, cracks, or gaps around the base so as to provide a
seal between the support and the base.
5. There are no obvious signs of deterioration of the fur-
nace.
6. Check for proper burner flame performance. Flame should
extend directly outward from burners without curling, float-
ing, or lifting off.