Specifications

4 www.goodmanmfg.com SS-GMVC96
SS-GMVC96 www.goodmanmfg.com 5
Airflow Data
GMVC960403BNA
Cooling Speed (@ .1" - .8" w.c. ESP)
GMVC960403BNA
Heating Speed @ .1" - .5" w.c. ESP; Rise Range: 35 - 65°F)
Tap Adjust
High-Stage
CFM
Low-Stage
CFM
Tap Adjust
High-Stage
CFM
Low-Stage
CFM
Rise
(°F)
A
Minus 10% 536 363
A
Minus 10% 891 658 n/a
Minus 5% 566 383 Minus 5% 941 694 n/a
Normal 596 403 Normal 990 731 n/a
Plus 5% 626 423 Plus 5% 1040 768 n/a
Plus 10% 656 443 Plus 10% 1089 804 65
B
Minus 10% 716 474
B
Minus 10% 977 720 n/a
Minus 5% 756 501 Minus 5% 1031 760 n/a
Normal 796 527 Normal 1085 800 64
Plus 5% 836 553 Plus 5% 1139 840 61
Plus 10% 876 580 Plus 10% 1194 880 58
C
Minus 10% 877 608
C
Minus 10% 1067 765 n/a
Minus 5% 925 641 Minus 5% 1126 808 62
Normal 974 675 Normal 1185 850 59
Plus 5% 1,023 709 Plus 5% 1244 893 56
Plus 10% 1,071 743 Plus 10% 1304 935 54
D
Minus 10% 1,073 723
D
Minus 10% 1151 820 58
Minus 5% 1,132 763 Minus 5% 1215 865 55
Normal 1,192 803 Normal 1279 911 53
Plus 5% 1,252 843 Plus 5% 1343 957 50
Plus 10% 1,311 883 Plus 10% 1407 1002 48
GMVC960603BNA
Cooling Speed (@ .1" - .8" w.c. ESP)
GMVC960603BNA
Heating Speed (@ .1" - .5" w.c. ESP; Rise Range: 20 - 50°F)
Tap Adjust
High-Stage
CFM
Low-Stage
CFM
Tap Adjust
High-Stage
CFM
Low-Stage
CFM
Rise
(°F)
A
Minus 10% 539 358
A
Minus 10% 858 600 n/a
Minus 5% 569 378 Minus 5% 905 634 n/a
Normal 599 398 Normal 953 667 n/a
Plus 5% 629 418 Plus 5% 1,001 700 n/a
Plus 10% 659 438 Plus 10% 1,048 734 n/a
B
Minus 10% 735 501
B
Minus 10% 953 666 n/a
Minus 5% 776 529 Minus 5% 1,006 703 n/a
Normal 817 557 Normal 1,059 740 50
Plus 5% 858 585 Plus 5% 1,112 777 48
Plus 10% 899 613 Plus 10% 1,165 814 46
C
Minus 10% 906 626
C
Minus 10% 1,042 727 n/a
Minus 5% 957 661 Minus 5% 1,100 768 48
Normal 1,007 696 Normal 1,158 808 46
Plus 5% 1,057 731 Plus 5% 1,216 848 44
Plus 10% 1,108 766 Plus 10% 1,274 889 42
D
Minus 10% 1,091 729
D
Minus 10% 1,134 793 47
Minus 5% 1,151 770 Minus 5% 1,197 837 45
Normal 1,212 810 Normal 1,260 881 42
Plus 5% 1,273 851 Plus 5% 1,323 925 40
Plus 10% 1,333 891 Plus 10% 1,386 969 38
Notes
All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
For most jobs, about 400 CFM per ton when cooling is desirable.
INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.
Minimum Filter Sizes
GMVC96
0403BNA
GMVC96
0603BNA
GMVC96
0803BNA
GMVC96
0804CNA
GMVC96
1005CNA
GMVC96
1005DNA
GMVC96
1205DNA
Filter Size (in²) (Qty) (1) 16 x 25 (side or boom) (1) 20 x 25 (boom) or (2) 16 x 25 (side)
Note: Other size lters of equal or greater dimensions may be used. Filters may also be centrally located.