Airflow Data (cont.)
GMVC961205DNA
Cooling Speed
( @ .1" - .8" w.c. ESP)
GMVC961205DNA
Heating Speed
(@ .1" - .5" w.c. ESP; Rise Range: 35 - 65°F)
Tap Adjust
High-Stage
CFM
Low-Stage
CFM
Tap Adjust
High-Stage
CFM
Low-Stage
CFM
Rise
(°F)
A
Minus 10% 780 492
A
Minus 10% 1,702 1,196 63
Minus 5% 824 520 Minus 5% 1,796 1,263 59
Normal 867 547 Normal 1,891 1,329 56
Plus 5% 910 574 Plus 5% 1,986 1,395 54
Plus 10% 954 602 Plus 10% 2,080 1,462 51
B
Minus 10% 1,044 748
B
Minus 10% 1,746 1,226 61
Minus 5% 1,102 789 Minus 5% 1,843 1,294 58
Normal 1,160 831 Normal 1,940 1,362 55
Plus 5% 1,218 873 Plus 5% 2,037 1,430 52
Plus 10% 1,276 914 Plus 10% 2,134 1,498 50
C
Minus 10% 1,320 918
C
Minus 10% 1,771 1,251 60
Minus 5% 1,394 969 Minus 5% 1,870 1,321 57
Normal 1,467 1,020 Normal 1,968 1,390 54
Plus 5% 1,540 1,071 Plus 5% 2,066 1,460 52
Plus 10% 1,614 1,122 Plus 10% 2,165 1,529 49
D
Minus 10% 1,719 1,150
D
Minus 10% 1,825 1,296 58
Minus 5% 1,815 1,214 Minus 5% 1,927 1,368 55
Normal 1,910 1,278 Normal 2,028 1,440 53
Plus 5% 2,006 1,342 Plus 5% 2,129 1,512 50
Plus 10% 2,101 1,406 Plus 10% 2,231 1,584 48
Notes
All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
For most jobs, about 400 CFM per ton when cooling is desirable.
INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.