Technical Information
FURNACE SPECIFICATIONS
4
¹NaturalGasBTU/h
²
³
Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run
and must be 2" or 3" diameter PVC.
⁴ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined
⁵
May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
•
•
•
and noise issues.
•
may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility
clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
*MVM97
0603BNA
*MVM97
0803BNA
*MVM97
0804CNA
*MVM97
1005CNA
*MVM97
1205DNA
Heating Data
High Fire Input¹ 60,000 80,000 80,000 100,000 120,000
High Fire Output¹ 58,200 77,600 77,600 97,000 116,400
Low-Fire Steady-State Input¹ 30,000 40,000 40,000 50,000 60,000
Low-Fire Steady-State Output¹ 29,100 38,800 38,800 48,500 58,200
AFUE² 9797979797
Temperature Ri se Ra nge (°F) 20 - 50 30 - 60 25 - 55 35 - 65 35 - 65
Vent Di ameter³ 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3"
No. of Burners 34456
Circulator Blower
Ava il abl e AC @ 0.5” ESP 1.5 - 3 1.5 - 3 1.5 - 4 41,675 41,675
Size (D x W) 11" x 8" 11" x 8" 11" x10" 11" x 10" 11" x 11"
Hors epower @ 1075 RPM 1/2 1/2 3/4 1 1
Speed VS ECMVS ECMVS ECMVS ECMVS ECM
Filter Size (in²)
Permanent 739 766 862 862 1035
Di s pos a bl e 370 383 431 431 517
Electrical Data
Min. Circuit Ampacity
4
8.8 8.8 11.6 15.4 15.4
Max. Overcurrent Device (a mps )
5
15 15 15 20 20
Shipping Weight (lbs)
118 121 142 144 157