Installation Instructions
26
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
HIGH VOLTAGE!
D ALL .
M. F
.
ISCONNECT POWER BEFORE SERVICING
ULTIPLE POWER SOURCES MAY BE PRESENT AILURE TO DO
SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH
[A/G]PD14[24-48]***M41** WIRING DIAGRAM
0140G04501-A
G
COMPONENT LEGEND
ALS AUXILLARY LIMIT SWITCH
C CONTACTOR
CH CRANKCASE HEATER
CHS CRANKCASE HEATER SWITCH
CM CONDENSER MOTOR
COMP COMPRESSOR
DC DEFROST CONTROL BOARD
DFT DEFROST THERMOSTAT
DR DEFROST RELAY
EM EVAPORATOR MOTOR
FFUSE
FS FLAME SENSOR
GND EQUIPMENT GROUND
GV GAS VALVE
HPS HIGH PRESSURE SWITCH
IIC INTEGRATED IGNITION CONTROL
IGN IGNITOR
LPS LOW PRESSURE SWITCH
LS LIMIT SWITCH
OTP OUTDOOR THERMOSTAT P LUG
P1 9 PIN CONNECTOR PLUG
P2 6 PIN CONNECTOR PLUG
PS PRESSURE SWITCH
RCCF RUN CAPACITOR COMPRESSOR / FAN
RS ROLLOUT SWITCH
RVC REVERSING VALVE COIL
TR TRANSFORMER
VM VENT MOTOR
F
ACTORY WIRING
NOTES
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF
INSULATION AS ORIGINAL (AT LEAST 105°C). USE COPPER
CONDUCTOR ONLY.
2. FOR 208V TRANSFORMER OPERATION MOVE BLACK WIRE FROM
TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
3. FOR 208V VENT MOTOR OPERATION, REMOVE BLUE LEAD FROM
INDUCER LOW TERMINAL. MOVE BLACK LEAD FROM PARK TERMINAL
TO INDUCER LOW TERMINAL, AND PLACE BLUE LEAD ON PARK.
4. USE COPPER CONDUCTORS ONLY.
++ USE NEC CLASS 2 WIRE.
5. FOR OUTDOOR THERMOSTAT, REMOVE PLUG FROM HARNESS AND
CONNECT PLUG FROM OUTDOOR THERMOSTAT TO HARNESS.
6. TO CHANGE AIRFLOW MOVE YELLOW WIRE (COOLING / HEAT PUMP),
WHITE WIRE (LOW STAGE GAS), OR BROWN WIRE (HIGH-STAGE GAS)
TO SPEED TAP T1, T2, T3, T4, OR T5 AT EVAPORATOR MOTOR.
REFER TO UNIT AIRFLOW TABLES FOR TO DETERMINE THE
APPROPRIATE SPEED TAP FOR APPLICATION. UNITS SHIPPED WITH
YELLOW, WHITE, AND BROWN ON T4, T1, AND T2 RESPECTIVELY.
7. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY
EQUIPPED WHEN REQUIRED.
8. DOUBLE POLE CONTACTOR SHOWN. SINGLE POLE CONTACTOR
COULD BE FACTORY EQUIPPED AS AN ALTERNATE CONFIGURATION.
LINE VOLTAGE
OPTIONAL HIGH
VOLTAGE
HIGH VOLTAGE
F
IELD WIRING
LOW VOLTAGE
LOW VOLTAGE
BK BLACK
W
IRE CODE
PK PINK
OR ORANGE
GR GREEN
BR BROWN
BL BLUE
RD RED
WH WHITE
YL YELLOW
PU PURPLE
COOL
HI HEAT
LO HEAT
P2
2
6
3
1
2
8
6
3
1
2
L1
L1
HI
LO
HI
DR
C
R
W
Y
O
C
HI
M
RS
PS
LSALS
TR
EM
VM
H
F
RCCF
C
L2
T2
208-230/1/6 0
CM
L1
R
T1
S
COMP
C
SUPPLY VOLTAGE
P1
-
REPLACE CONTROL
CHECK
CH E CK FO R SH ORTS I N
FLAME SENSOR WIRING
-NORMAL FLAME PRESENT
DIAGNOSTIC
LED - AMBER
-
GA S PRE SSURE
FLAME SENSOR
GAS VALVE
GAS FL OW
CHECK GAS VALVE
ON
OFF
1FLASH
2 FLASHES
FALS E FLAME DETECTED
LOW FLAME SIGNAL
NO FLAME PRESENT
STATUS
CHECK
PSW /LOC OPEN
9 FLASHES
CH ECK JUMPER BETWEEN
1AND4ON 6-CIRCUIT
CONNECTOR
IDT/ODT OP EN8 FLASHES
CHECK AUXILIARY LIMIT SW.
CHECK MAIN LIMI T SWITCH
LIMIT OPEN 5 TIMES IN
SAME CALL FOR HEAT
3MINCOMP.SHORT
CYCLE DELAY
COMPR. SHORT CYCLE DELAY
6 FLASHES
DIAGNOSTIC
LED - RED
7 FLASHES
STATUS
CHECK
DIAGNOSTIC
LED - RED
CH EC K FOR SH OR TS IN
FLAME SENSOR WIRING
CHECK GAS VALVE
CHECK ROLL OU T LIMIT SW .
CHECK AUXILIARY LIMIT SW .
CH ECK M AIN LIMI T SWITCH
CHECK WIRING FOR SHOR TS
CHECK PRE SSURE SWITCHPRESSURE SWITCH CLOSED
CH ECK VENT MOTOR
CH E CK T UB I NG
CHECK FUSE(S)
CHECK INPUT POWER
-
GA S PRESSURE
FLAME SENSOR
GAS VALVE
GA S FL O W
CHECK PRE SSURE SWITCH
OFF
ON
1FLASH
3 FLASHES
2 FLASHES
4 FLASHES
5 FLASHES
FALS E FLAME DETE CTED
OPEN LIMIT SW ITCH
WITHOU T INDUCER ON
PRESSURE SW ITCH OPEN
IGNITION FAILURE
NORMAL OPER ATION
NO POWER OR
INTERNA L CONTROL
FAULT
STATUS
CHECK
C
C
F
Y1
RC
W2
W1
TO
MICRO
TO
MICRO
L1
L2
CHECK OPT IONAL
REFRIGERANT SWITCHES
CHECK REFRIGERANT
SWITCHES FOR LOSS OF
CHARGEORHIGHHEAD
PRESSURE
HPS
LPS
DF1
HVDR
DC
DF2
ODF
CHS
INDUCER
IIC
PARK
3
4
1
2
5
1
2
3
5
4
1
6
G
Y1
R
C
Y2
W2
O
OTP
3
2
1
T5
T1
T3
T2
EM
C
O-RV
CNT
C-RV
R-DFT
PS2
DC
R-PS1
RVC
DFT
C
DFT
LO
L2
L2
L2
L2
CH
GV
W1
R
C
W1 GY1Y2
W2
IIC
T4
++
THERMOSTAT
5
7
9
SEE NOTE 2
SEE NOTE 3
SEE NOTE 5
SEE NOTE 6
SEE NOTE 7
SEE NOTE 8
P9
EQUIPMENT GROUND
FIELD GROUND
FIELD SPLICE
SWITCH (TEMP)
IGNITER
SWITCH (PRESS.)
OVERCURRENT
PROT. DEVICE
JUNCTION
TERMINAL
INTERNAL TO
INTEGRATED CONTROL
PLUG CONNEC TION