Product Overview

14 www.goodmanmfg.com SS-GPD14M
SS-GPD14M www.goodmanmfg.com 15
Expanded Heating Data (cont.)
GPD1442***M41**

65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 52.9 50.0 47.1 44.0 42.1 40.7 37.8 34.9 30.1 27.8 25.6 24.2 23.3 20.9 18.5 16.1 13.8 11.3
T/R 35.0 33.1 31.1 29.1 27.8 27.0 25.0 23.1 19.9 18.4 16.9 16.0 15.4 13.8 12.2 10.7 9.1 7.5
kW 3.58 3.51 3.44 3.37 3.33 3.30 3.23 3.16 3.01 2.95 2.88 2.84 2.82 2.75 2.68 2.62 2.55 2.49
Amps 18.1 16.8 15.9 15.0 14.5 14.3 13.5 12.9 12.4 12.0 11.5 11.2 11.1 10.6 10.0 9.5 8.9 8.2
COP 4.33 4.18 4.01 3.82 3.70 3.61 3.43 3.23 2.92 2.76 2.60 2.49 2.42 2.22 2.02 1.80 1.58 1.33
EER 14.8 14.3 13.7 13.1 12.6 12.3 11.7 11.0 10.0 9.4 8.9 8.5 8.3 7.6 6.9 6.2 5.4 4.5
HI PR 414 397 382 365 357 350 336 323 309 295 283 277 272 261 251 241 232 224
LO PR 142 132 123 113 107 103 95 84 76 68 60 55 53 45 39 33 29 23
GPD1448***M41**

65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 56.7 53.7 50.5 47.2 45.1 43.7 40.6 37.4 32.8 30.3 27.9 26.3 25.3 22.7 20.2 17.6 15.0 12.3
T/R 33.9 32.1 30.2 28.2 26.9 26.1 24.2 22.4 19.6 18.1 16.6 15.7 15.1 13.6 12.0 10.5 9.0 7.3
kW 3.92 3.85 3.77 3.70 3.65 3.62 3.55 3.48 3.31 3.24 3.17 3.12 3.10 3.02 2.95 2.88 2.81 2.74
Amps 19.4 18.1 17.1 16.2 15.7 15.4 14.6 14.0 13.5 12.9 12.4 12.2 12.0 11.5 10.9 10.3 9.7 8.9
COP 4.23 4.08 3.92 3.74 3.61 3.53 3.35 3.15 2.90 2.74 2.58 2.46 2.39 2.20 2.00 1.78 1.56 1.31
EER 14.5 14.0 13.4 12.8 12.3 12.1 11.4 10.8 9.9 9.3 8.8 8.4 8.2 7.5 6.8 6.1 5.3 4.5
HI PR 406 389 374 358 349 343 329 316 303 289 278 271 266 256 246 236 228 220
LO PR 132 122 115 105 99 96 88 78 71 63 55 52 50 42 36 31 27 21
Above informaon is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed. KW = Total system power
High pressure is measured at the liquid line access ng. AMPS: Unit amps (comp.+ evaporator motor + condenser fan motor)
Low pressure is measured at the compressor sucon access ng.