Installation Guide

2 www.goodmanmfg.com SS-GPG14M
SS-GPG14M www.goodmanmfg.com 3

GPG1424
040M41AA
GPG1424
060M41AA
GPG1430
040M41AA
GPG1430
060M41AA
GPG1430
040M41B*
GPG1430
060M41B*
GPG1436
040M41AA

Total BTU/h 23,000 23,000 28,600 28,600 28,600 28,600 34,200
Sensible BTU/h 18,400 18,400 22,800 22,800 22,400 22,400 27,000
SEER / EER 14.0 / 11.0 14.0 / 11.0 14.0 / 11.0 14.0 / 11.0 14.0 / 11.0 14.0 / 11.0 14.0 / 11.0
Decibels 78 78 78 78 78 78 78
AHRI Reference #s 7505444 7505444 7505448 7505448 9101255 9101255 7505445

Input BTU/h 40,000 60,000 40,000 60,000 40,000 60,000 40,000
Output BTU/h 31,000 48,000 31,000 48,000 31,000 48,000 31,000
AFUE 81 81 81 81 81 81 81
Temperature Rise Range 25 - 55 30 - 60 25 - 55 30 - 60 25 - 55 30 - 60 25 - 55
No. of Burners 2 3 2 3 2 3 2
Orice Size (Natural/Propane) 45 / 1.25MM 45 / 1.25MM 45 / 1.25MM 45 / 1.25MM 45 / 1.25MM 45 / 1.25MM 45 / 1.25MM

Type ECM ECM ECM ECM ECM ECM ECM
Wheel (D x W) 10” x 8” 10” x 8” 10” x 8” 10” x 8” 10” x 8” 10” x 8” 10” x 9”
Indoor Nominal CFM 800 800 1,000 1,000 1,000 1,000 1,200
Motor Speed Tap (Cooling) T4 T4 T4 T4 T4 T4 T4
RPM/Amps (Cooling) 1050/3.9 1050/3.9 1050/3.9 1050/3.9 1050/3.9 1050/3.9 1050/3.9
Horsepower 1/2 1/2 1/2 1/2 1/2 1/2 1/2

Face Area (²) 4.3 4.3 4.3 4.3 4.3 4.3 4.3
Rows Deep/Fins per Inch 3/14 3/14 3/14 3/14 3/14 3/14 4/14
Piston Size (Cooling) 0.057 0.057 0.062 0.062 0.062 0.062 0.068
Filter Size (²) 2.7 3.3 3.4 3.4 3.4 3.4 4.0
Drain Size (NPT) ¾” ¾” ¾” ¾” ¾” ¾” ¾”
Refrigerant Charge (oz.) 75 75 78 78 78 78 62

Horsepower - RPM 1/6 - 815 1/6 - 815 1/4 - 1,075 1/4 - 1,075 1/4 - 1,075 1/4 - 1,075 1/4 - 830
Diameter / # of Blades 22” / 3 22” / 3 22” / 3 22” / 3 22” / 3 22” / 3 22” / 3
Outdoor Nominal CFM 2,150 2,150 3,050 3,050 3,050 3,050 2,250
Face Area (²) 12.3 12.3 12.3 12.3 12.3 12.3 8.8
Rows Deep/Fins per Inch 1/24 1/24 1/24 1/24 1/24 1/24 2/27

Quanty / Type 1 / Rotary 1 / Rotary 1 / Scroll 1 / Scroll 1 / Rotary 1 / Rotary 1 / Scroll
Stage Single Single Single Single Single Single Single
Compressor RLA/LRA 7.7 / 37.0 7.7 / 37.0 14.1 / 73 14.1 / 73 10.5/47.0 10.5/47.0 14.1/77.0

Voltage-Phase (60 Hz) 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1
Indoor Blower FLA 3.9 3.9 3.9 3.9 3.9 3.9 3.9
Outdoor Fan FLA/LRA 1.1 / 1.7 1.1 / 1.7 1.4 / 2.9 1.4 / 2.9 1.4 / 2.9 1.4 / 2.9 1.5 / 3.0
Total Unit Amps 12.7 12.7 19.4 19.4 15.8 15.8 19.5
Min. Circuit Ampacity 14.6 14.6 22.9 22.9 18.4 18.4 23
Max. Overcurrent Protecon 20 amps 20 amps 35 amps 35 amps 25 25 35 amps
Entrance Size Power Supply 1⅛” 1⅛” 1⅛” 1⅛” 1⅛” 1⅛” 1⅛”
Entrance Size Control Voltage ⅞” ⅞” ⅞” ⅞” ⅞” ⅞” ⅞”

412 / 435 417 / 439 415 / 438 420 / 442 412 / 435 417 / 439 449 / 470
¹ Wire size should be determined in accordance with Naonal Electrical Codes. Extensive wire runs will require larger wire sizes.
² Must use me-delay fuses or HACR-type circuit breakers of the same size as noted.
Always check the S&R plate for electrical data on the unit being installed.