GPG14 Spec Sheet
4 www.goodmanmfg.com SS-GPG14M
SS-GPG14M www.goodmanmfg.com 5
GPG1436
060M41BA
GPG1436
080M41BA
GPG1442
060M41AA
GPG1442
080M41AA
GPG1448
060M41AA
GPG1448
080M41AA
GPG1448
100M41AA
Total BTU/h 34,200 34,200 40,000 40,000 46,500 46,500 46,500
Sensible BTU/h 27,000 27,000 30,000 30,000 36,800 36,800 36,800
SEER / EER 14.0 / 11.0 14.0 / 11.0 14.0 / 11.0 14.0 / 11.0 14.0 / 11.0 14.0 / 11.0 14.0 / 11.0
Decibels 78 78 78 78 80 80 80
AHRI Reference #s 7505445 7505445 7505449 7505449 7505446 7505446 7505446
Input BTU/h 60,000 80,000 60,000 80,000 60,000 80,000 100,000
Output BTU/h 48,000 64,000 48,000 64,000 48,000 64,000 80,000
AFUE 81 81 81 81 81 81 81
Temperature Rise Range 30 - 60 30 - 60 30 - 60 30 - 60 30 - 60 30 - 60 35 - 65
No. of Burners 3 4 3 4 3 4 5
Orice Size (Natural/Propane) 45 / 1.25MM 45 / 1.25MM 45 / 1.25MM 45 / 1.25MM 45 / 1.25MM 45 / 1.25MM 45 / 1.25MM
Type ECM ECM ECM ECM ECM ECM ECM
Wheel (D x W) 10” x 9” 10” x 9” 10” x 9” 10” x 9” 11” x 10” 11” x 10” 11” x 10”
Indoor Nominal CFM 1,200 1,200 1,300 1,300 1,525 1,525 1,525
Motor Speed Tap (Cooling) T4 T4 T4 T4 T4 T4 T4
RPM/Amps (Cooling) 1050/3.9 1050/3.9 1050/5.7 1050/5.7 1,050/5.7 1,050/5.7 1,050/5.7
Horsepower 1/2 1/2 3/4 3/4 3/4 3/4 3/4
Face Area (²) 4.3 4.3 4.3 4.3 5.7 5.7 5.7
Rows Deep/Fins per Inch 4/14 4/14 4/14 4/14 4/14 4/14 4/14
Piston Size (Cooling) 0.068 0.068 0.072 0.072 0.078 0.078 0.078
Filter Size (²) 4.0 4.4 4.3 4.4 5.1 5.1 5.1
Drain Size (NPT) ¾” ¾” ¾” ¾” ¾” ¾” ¾”
Refrigerant Charge (oz.) 72 72 88 88 99 99 99
Horsepower - RPM 1/4 - 830 1/4 - 830 1/4 - 1,075 1/4 - 1,075 1/4 - 1,075 1/4 - 1,075 1/4 - 1,075
Diameter / # of Blades 22” / 3 22” / 3 22” / 3 22” / 3 22” / 3 22” / 3 22” / 3
Outdoor Nominal CFM 2,250 2,250 2,850 2,850 3,300 3,300 3,300
Face Area (²) 8.8 8.8 11.1 11.1 15.4 15.4 15.4
Rows Deep/Fins per Inch 2/27 2/27 2/27 2/27 1/24 1/24 1/24
Quanty / Type 1 / Rotary 1 / Rotary 1 / Scroll 1 / Scroll 1 / Scroll 1 / Scroll 1 / Scroll
Stage Single Single Single Single Single Single Single
Compressor RLA/LRA 12.7 / 55.3 12.7 / 55.3 17.9 / 112 17.9 / 112 19.9/109 19.9/109 19.9/109
Voltage-Phase (60 Hz) 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1
Indoor Blower FLA 3.9 3.9 5.7 5.7 5.7 5.7 5.7
Outdoor Fan FLA/LRA 1.5 / 3.0 1.5 / 3.0 1.4/ 2.9 1.4/ 2.9 1.4/ 2.9 1.4/ 2.9 1.4/ 2.9
Total Unit Amps 19.5 19.5 22.3 22.3 27.0 27.0 27.0
Min. Circuit Ampacity 21.0 21.0 26.8 26.8 32 32 32
Max. Overcurrent Protecon 30 amps 30 amps 40 amps 40 amps 50 amps 50 amps 50 amps
Entrance Size Power Supply 1⅛” 1⅛” 1⅛” 1⅛” 1⅛” 1⅛” 1⅛”
Entrance Size Control Voltage ⅞” ⅞” ⅞” ⅞” ⅞” ⅞” ⅞”
453 / 475 458 / 480 493 / 515 496 / 520 518 / 540 523 / 545 528 / 550
¹ Wire size should be determined in accordance with Naonal Electrical Codes. Extensive wire runs will require larger wire sizes.
² Must use me-delay fuses or HACR-type circuit breakers of the same size as noted.
Always check the S&R plate for electrical data on the unit being installed.