Specifications

4 www.goodmanmfg.com SS-GPG14M
SS-GPG14M www.goodmanmfg.com 5

GPG1460
080M41AA
GPG1460
100M41AA
GPG1460
120M41AA
GPG1461
080M41A*
GPG1461
100M41A*
GPG1461
120M41A*

Total BTU/h 57,500 57,500 57,500 57,500 57,500 57,500
Sensible BTU/h 44,500 44,500 44,500 42,000 42,000 42,000
SEER / EER 14.2 / 10.1 14.2 / 10.1 14.2 / 10.1 14.0 / 11.0 14.0 / 11.0 14.0 / 11.0
Decibels 78 78 78 78 78 78
AHRI Reference #s 7505447 7505447 7505447 8321898 8321898 8321898

High-Fire Input / Output 80,000 / 63,000 100,000 / 78,000 120,000 / 94,000 80,000 / 63,000 100,000 / 78,000 120,000 / 94,000
Low-Fire Input / Output 60,000 / 47,000 75,000 / 58,000 90,000 / 71,000 60,000 / 47,000 75,000 / 58,000 90,000 / 71,000
AFUE 81 81 81 81 81 81
Temperature Rise Range 30 - 60 35 - 65 35 - 65 30 - 60 35 - 65 35 - 65
No. of Burners 4 5 6 4 5 6
Orice Size (Natural/Propane) 45 / 1.25MM 45 / 1.25MM 45 / 1.25MM 45 / 1.25MM 45 / 1.25MM 45 / 1.25MM

Type ECM ECM ECM ECM ECM ECM
Wheel (D x W) 11” x 10” 11” x 10” 11” x 10” 11” x 10” 11” x 10” 11” x 10”
Indoor Nominal CFM 1,810 1,810 1,810 1,750 1,750 1,750
Motor Speed Tap (Cooling) T3 L / T4 H T3 L / T4 H T3 L / T4 H T3 L / T4 H T3 L / T4 H T3 L / T4 H
RPM/Amps (Cooling) 1,050/7.0 1,050/7.0 1,050/7.0 1,050/7.0 1,050/7.0 1,050/7.0
Horsepower 1 1 1 1 1 1

Face Area (²) 5.7 5.7 5.7 5.7 5.7 5.7
Rows Deep/Fins per Inch 4/14 4/14 4/14 4/14 4/14 4/14
Piston Size (Cooling) TXV TXV TXV TXV TXV TXV
Filter Size (²) 6.0 6.0 6.0 6.0 6.0 6.0
Drain Size (NPT) ¾” ¾” ¾” ¾” ¾” ¾”
Refrigerant Charge (oz.) 100 100 100 100 100 100

Horsepower - RPM 1/4 - 1,075 1/4 - 1,075 1/4 - 1,075 1/3 - 1,122 1/3 - 1,122 1/3 - 1,122
Diameter / # of Blades 22” / 3 22” / 3 22” / 3 22” / 3 22” / 3 22” / 3
Outdoor Nominal CFM 3,000 3,000 3,000 3,000 3,000 3,000
Face Area (²) 11.3 11.3 11.3 14.4 14.4 14.4
Rows Deep/Fins per Inch 2/27 2/27 2/27 2/27 2/27 2/27

Quanty / Type 1 / Scroll 1 / Scroll 1 / Scroll 1 / Scroll 1 / Scroll 1 / Scroll
Stage Two Two Two Two Two Two
Compressor RLA/LRA 27.1 / 152.9 27.1 / 152.9 27.1 / 152.9 28.8 / 152.9 28.8 / 152.9 28.8 / 152.9

Voltage-Phase (60 Hz) 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1
Indoor Blower FLA 7.0 7.0 7.0 7.0 7.0 7.0
Outdoor Fan FLA/LRA 1.4/ 2.9 1.4/ 2.9 1.4/ 2.9 2.0 / 4.40 2.0 / 4.40 2.0 / 4.40
Total Unit Amps 35.5 35.5 35.5 30 30 30
Min. Circuit Ampacity 42.3 42.3 42.3 35.0 35.0 35.0
Max. Overcurrent Protecon 60 amps 60 amps 60 amps 50 amps 50 amps 50 amps
Entrance Size Power Supply 1⅛” 1⅛” 1⅛” 1⅛” 1⅛” 1⅛”
Entrance Size Control Voltage ⅞” ⅞” ⅞” ⅞” ⅞” ⅞”

533 / 555 538 / 560 543 / 565 533 / 555 538 / 560 543 / 565
¹ Wire size should be determined in accordance with Naonal Electrical Codes. Extensive wire runs will require larger wire sizes.
² Must use me-delay fuses or HACR-type circuit breakers of the same size as noted.

Always check the S&R plate for electrical data on the unit being installed.
Test data was use to calculate the MOP and MCA.