GPGM3 Spec Sheet
2 www.goodmanmfg.com SS-GPGM3
SS-GPGM3 www.goodmanmfg.com 3
GPGM3
2404041
GPGM3
2406041
GPGM3
3004041
GPGM3
3006041
GPGM3
3604041
GPGM3
3606041
Total BTU/h 23,000 23,000 28,600 28,600 34,200 34,200
Sensible BTU/h 18,800 18,800 23,080 23,080 28,160 28,160
SEER2 / EER2 13.4 / 10.6 13.4 / 10.6 13.4 / 10.6 13.4 / 10.6 13.4 / 10.6 13.4 / 10.6
Decibels 78 78 78 78 78 78
AHRI Reference #s 209319520 209319520 209319526 209319526 209319532 209319532
Input BTU/h 40,000 60,000 40,000 60,000 40,000 60,000
Output BTU/h 32,400 48,600 32,400 48,600 32,400 48,600
AFUE 81 81 81 81 81 81
Temperature Rise Range 25 - 55 30 - 60 25 - 55 30 - 60 25 - 55 30 - 60
No. of Burners 2 3 2 3 2 3
Type ECM ECM ECM ECM ECM ECM
Wheel (D x W) 10” x 8” 10” x 8” 10” x 8” 10” x 8” 10” x 9” 10” x 9”
Indoor Nominal CFM 800 800 1,000 1,000 1,200 1,200
No. of Speeds 5 5 5 5 5 5
Horsepower 1/2 1/2 1/2 1/2 1/2 1/2
Face Area (²) 4.35 4.35 4.35 4.35 4.35 4.35
Rows Deep/Fins per Inch 3/14 3/14 3/14 3/14 4/14 4/14
Piston Size (Cooling) 0.057 0.057 0.062 0.062 0.068 0.068
Drain Size (NPT) ¾” ¾” ¾” ¾” ¾” ¾”
Refrigerant Charge (oz.) 75 75 78 78 92 92
Horsepower - RPM 1/6 - 815 1/6 - 815 1/4 - 1,075 1/4 - 1,075 1/4 - 1,075 1/4 - 1,075
Diameter / # of Blades 22” / 3 22” / 3 22” / 3 22” / 3 22” / 3 22” / 3
Outdoor Nominal CFM 2,150 2,150 3,050 3,050 2,250 2,250
Face Area (²) 12.3 12.3 12.3 12.3 11.13 11.13
Rows Deep/Fins per Inch 1/24 1/24 1/24 1/24 2/27 2/27
Quanty / Type 1 / Scroll 1 / Scroll 1 / Scroll 1 / Scroll 1 / Scroll 1 / Scroll
Stage Single Single Single Single Single Single
Compressor RLA/LRA 7.7 / 38.0 7.7 / 38.0 14.1 / 73.0 14.1 / 73.0 14.1 / 77.0 14.1 / 77.0
Voltage-Phase (Frequency 60Hz) 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1
Indoor Blower FLA 3.8 3.8 3.8 3.8 3.8 3.8
Outdoor Fan FLA/LRA 0.95/2.0 0.95/2.0 1.4 / 3.2 1.4 / 3.2 1.4 / 3.2 1.4 / 3.2
Min. Circuit Ampacity 21.6 21.6 22.8 22.8 22.8 22.8
Max. Overcurrent Protecon 35 amps 35 amps 35 amps 35 amps 35 amps 35 amps
412 / 435 417 / 439 415 / 438 420 / 442 449 / 470 453 / 475
¹ Wire size should be determined in accordance with Naonal Electrical Codes. Extensive wire runs will require larger wire sizes.
² Must use me-delay fuses or HACR-type circuit breakers of the same size as noted.
Always check the S&R plate for electrical data on the unit being installed.