Specifications

16 www.goodmanmfg.com SS-GPH14M
SS-GPH14M www.goodmanmfg.com 17
Expanded Heating Data
GPH1424M41A*

65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 28.9 27.4 25.8 24.1 23.0 22.3 20.7 19.1 15.7 14.5 13.3 12.6 12.1 10.9 9.7 8.4 7.2 5.9
T/R 31.5 29.8 28.1 26.2 25.1 24.3 22.5 20.8 17.1 15.8 14.5 13.7 13.2 11.9 10.5 9.2 7.8 6.4
kW 1.90 1.87 1.83 1.79 1.77 1.75 1.72 1.68 1.70 1.66 1.62 1.60 1.58 1.55 1.51 1.47 1.43 1.39
Amps 10.1 9.4 8.9 8.5 8.2 8.1 7.7 7.4 7.1 6.9 6.6 6.5 6.4 6.1 5.8 5.6 5.2 4.8
COP 4.45 4.29 4.12 3.93 3.80 3.72 3.53 3.32 2.70 2.55 2.41 2.30 2.24 2.06 1.87 1.68 1.47 1.24
HI PR 377 361 347 332 324 318 306 293 281 269 258 252 247 238 229 219 211 204
LO PR 139 129 121 111 105 101 92 82 74 66 58 54 52 44 38 32 28 22
GPH1430M41A*

65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 35.2 33.3 31.4 29.3 28.0 27.1 25.2 23.2 18.7 17.3 15.9 15.0 14.4 13.0 11.5 10.0 8.6 7.0
T/R 31.0 29.4 27.7 25.9 24.7 23.9 22.2 20.5 16.5 15.2 14.0 13.2 12.7 11.4 10.1 8.8 7.5 6.2
kW 2.36 2.31 2.26 2.21 2.19 2.17 2.12 2.07 2.05 2.00 1.95 1.93 1.91 1.86 1.81 1.77 1.72 1.67
Amps 5.6 5.4 5.1 4.9 4.8 4.8 4.6 4.5 4.3 4.2 4.1 4.1 4.0 3.9 3.8 3.7 3.5 3.4
COP 4.37 4.22 4.06 3.87 3.75 3.66 3.48 3.28 2.67 2.52 2.38 2.28 2.22 2.04 1.86 1.66 1.46 1.23
HI PR 385 370 355 340 332 325 313 300 288 275 264 257 253 243 234 224 216 209
LO PR 138 128 120 110 104 100 92 82 74 66 58 54 52 44 38 32 28 22
GPH1436M41A*

65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 41.7 39.5 37.2 34.8 33.2 32.2 29.9 27.6 23.7 21.9 20.1 19.0 18.3 16.4 14.6 12.7 10.8 8.9
T/R 32.2 30.5 28.7 26.8 25.6 24.8 23.1 21.3 18.3 16.9 15.5 14.7 14.1 12.7 11.2 9.8 8.4 6.8
kW 2.76 2.71 2.66 2.60 2.57 2.55 2.49 2.44 2.53 2.47 2.41 2.38 2.36 2.30 2.24 2.18 2.13 2.07
Amps 7.0 6.6 6.4 6.1 6.0 5.9 5.7 5.5 5.4 5.2 5.1 5.0 5.0 4.9 4.7 4.5 4.4 4.2
COP 4.42 4.27 4.10 3.91 3.78 3.70 3.51 3.30 2.74 2.59 2.44 2.34 2.27 2.09 1.90 1.70 1.49 1.26
HI PR 391 375 361 345 337 330 318 305 292 279 268 261 257 247 237 228 220 212
LO PR 134 125 117 107 101 97 90 80 72 64 57 53 51 43 37 31 27 21
Notes
Above informaon is for nominal CFM and 70-degree indoor dry bulb. Instantaneous capacity listed.
High pressure is measured at the liquid line access ng. Amps: Unit amps (comp.+ evaporator motor + condenser fan motor)
Low pressure is measured at the compressor sucon access ng. kW = Total system power