GPH14H Technical Manual
31
COOLING PERFORMANCE DATA *PH1460H41**
MODEL: *PH1460H41**
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Design Subcooling, 7 ± 2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 7 ± 2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 596367715963677159636771596367715963677159636771
MBh 55.9 57.9 63.4 - 54.6 56.5 62.0 - 53.3 55.2 60.5 - 52.0 53.9 59.0 - 49.4 51.2 56.1 - 45.7 47.4 51.9 -
S/T 0.71 0.59 0.41 - 0.74 0.62 0.43 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.68 0.47 - 0.82 0.68 0.47 -
Delta T 20 18 13 - 21 18 14 - 21 18 14 - 21 18 14 - 20 18 13 - 19 17 13 -
1798 KW 3.69 3.77 3.90 - 3.99 4.08 4.22 - 4.25 4.35 4.49 - 4.48 4.58 4.74 - 4.68 4.79 4.95 - 4.85 4.96 5.13 -
AMPS 15.6 15.9 16.4 - 16.8 17.1 17.7 - 18.1 18.5 19.1 - 19.3 19.7 20.4 - 20.5 20.9 21.6 - 21.6 22.1 22.8 -
HI PR 237 255 269 - 266 286 302 - 302 325 343 - 344 370 391 - 387 417 440 - 428 460 486 -
LO PR 107 114 124 - 113 120 131 - 118 125 137 - 124 131 144 - 130 138 150 - 134 143 156 -
MBh 54.2 56.2 61.6 - 53.0 54.9 60.1 - 51.7 53.6 58.7 - 50.4 52.3 57.3 - 47.9 49.7 54.4 - 44.4 46.0 50.4 -
S/T 0.68 0.57 0.39 - 0.70 0.59 0.41 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.77 0.65 0.45 - 0.78 0.65 0.45 -
Delta T 21 18 14 - 21 19 14 - 21 19 14 - 22 19 14 - 21 18 14 - 20 17 13 -
70 1600 KW 3.66 3.74 3.87 - 3.96 4.04 4.18 - 4.22 4.31 4.46 - 4.44 4.55 4.70 - 4.64 4.75 4.91 - 4.81 4.92 5.09 -
AMPS 15.5 15.8 16.3 - 16.6 17.0 17.5 - 18.0 18.4 18.9 - 19.1 19.6 20.2 - 20.3 20.8 21.4 - 21.4 21.9 22.6 -
HI PR 234 252 266 - 263 283 299 - 299 322 340 - 341 367 387 - 383 412 435 - 423 456 481 -
LO PR 106 113 123 - 112 119 130 - 116 124 135 - 122 130 142 - 128 136 149 - 133 141 154 -
MBh 50.1 51.9 56.8 - 48.9 50.7 55.5 - 47.7 49.5 54.2 - 46.6 48.3 52.9 - 44.2 45.8 50.2 - 41.0 42.5 46.5 -
S/T 0.65 0.55 0.38 - 0.68 0.57 0.39 - 0.70 0.58 0.40 - 0.72 0.60 0.42 - 0.75 0.62 0.43 - 0.75 0.63 0.43 -
Delta T 21 19 14 - 22 19 14 - 22 19 14 - 22 19 14 - 22 19 14 - 20 17 13 -
1402 KW 3.57 3.65 3.77 - 3.86 3.94 4.07 - 4.11 4.20 4.34 - 4.33 4.43 4.58 - 4.52 4.62 4.78 - 4.68 4.79 4.95 -
AMPS 15.1 15.4 15.9 - 16.2 16.6 17.1 - 17.5 17.9 18.5 - 18.6 19.1 19.7 - 19.8 20.2 20.8 - 20.9 21.3 22.0 -
HI PR 227 245 258 - 255 275 290 - 290 312 330 - 330 356 375 - 372 400 422 - 411 442 467 -
LO PR 103 109 120 - 109 116 126 - 113 120 131 - 119 126 138 - 124 132 144 - 129 137 149 -
MBh 56.8 58.5 63.3 67.9 55.5 57.1 61.8 66.4 54.2 55.8 60.4 64.8 52.8 54.4 58.9 63.2 50.2 51.7 55.9 60.0 46.5 47.9 51.8 55.6
S/T 0.81 0.72 0.55 0.35 0.84 0.75 0.57 0.37 0.86 0.77 0.58 0.37 0.89 0.79 0.60 0.39 0.92 0.82 0.62 0.40 0.93 0.83 0.63 0.40
Delta T242218122422181224221812242218122422181222201712
1798 KW 3.72 3.81 3.93 4.06 4.02 4.11 4.25 4.40 4.29 4.39 4.53 4.69 4.52 4.63 4.78 4.95 4.72 4.83 4.99 5.17 4.89 5.00 5.18 5.36
AMPS 15.7 16.1 16.6 17.1 16.9 17.3 17.8 18.4 18.3 18.7 19.3 20.0 19.5 19.9 20.5 21.3 20.6 21.1 21.8 22.6 21.8 22.3 23.0 23.9
HI PR 239 257 272 283 268 289 305 318 305 328 347 362 348 374 395 412 391 421 444 463 432 465 491 512
LO PR 108 115 126 134 114 122 133 141 119 126 138 147 125 133 145 154 131 139 152 162 135 144 157 167
MBh 55.1 56.8 61.5 66.0 53.9 55.5 60.0 64.4 52.6 54.1 58.6 62.9 51.3
52.8
57.2 61.4 48.7 50.2 54.3 58.3 45.1 46.5 50.3 54.0
S/T 0.77 0.69 0.52 0.34 0.80 0.72 0.54 0.35 0.82 0.73 0.56 0.36 0.85
0.76
0.57 0.37 0.88 0.79 0.59 0.38 0.89 0.79 0.60 0.39
Delta T24231813252319132523191325
23
19 13 25 23 19 13 23 21 17 12
75 1600 KW 3.69 3.78 3.90 4.03 3.99 4.08 4.22 4.36 4.25 4.35 4.50 4.65 4.48
4.59
4.74 4.91 4.68 4.79 4.95 5.12 4.85 4.96 5.13 5.31
AMPS 15.6 15.9 16.4 17.0 16.8 17.1 17.7 18.3 18.1 18.5 19.1 19.8 19.3
19.7
20.4 21.1 20.5 20.9 21.6 22.4 21.6 22.1 22.8 23.7
HI PR 237 255 269 281 266 286 302 315 302 325 343 358 344
370
391 408 387 417 440 459 428 460 486 507
LO PR 107 114 124 133 113 120 131 140 118 125 137 146 124
131
144 153 130 138 150 160 134 143 156 166
MBh 50.9 52.4 56.7 60.9 49.7 51.2 55.4 59.5 48.5 50.0 54.1 58.1 47.3 48.8 52.8 56.6 45.0 46.3 50.1 53.8 41.7 42.9 46.4 49.8
S/T 0.74 0.67 0.50 0.32 0.77 0.69 0.52 0.34 0.79 0.71 0.54 0.34 0.82 0.73 0.55 0.36 0.85 0.76 0.57 0.37 0.85 0.76 0.58 0.37
Delta T252319132523191325231913252319132523191323221812
1402 KW 3.60 3.68 3.80 3.93 3.89 3.98 4.11 4.25 4.14 4.24 4.38 4.53 4.37 4.47 4.62 4.78 4.56 4.66 4.82 4.99 4.72 4.83 5.00 5.17
AMPS 15.2 15.5 16.0 16.6 16.3 16.7 17.2 17.8 17.7 18.1 18.6 19.3 18.8 19.2 19.8 20.5 19.9 20.4 21.0 21.8 21.0 21.5 22.2 23.0
HI PR 230 247 261 272 258 277 293 305 293 315 333 347 334 359 379 396 376 404 427 445 415 447 471 492
LO PR 104 111 121 129 110 117 128 136 114 121 133 141 120 128 139 148 126 134 146 155 130 138 151 161
* IDB: Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TV A) conditions
High and low pressures are measured at the liquid and suction access f ittings.