Specifications
Table Of Contents
Product SPecificationS
Product SPecificationS
4 www.goodmanmfg.com SS-GPH14H
SpecificationS (cont.)
GPH14
42H41A*
GPH14
42H41C*
GPH14
48H41A*
GPH14
48H41C*
GPH14
60H41A*
GPH14
60H41B*
AHRI Cooling Capacity (BTU/h) 40,500 40,500 46,000 46,000 57,000 57,000
Sensible BTU/h 29,600 29,600 35,400 35,400 40,500 40,500
SEER / EER 14.0 / 12.0 14.0 / 12.0 14.0 / 12.0 14.0 / 12.0 14.0 / 12 14.0 / 12
Decibels 78 78 80 80 80 80
AHRI Numbers 4385135 5677877 4385136 5677878 4385137 TBD
BTU/h (47°F) 37,600 37,600 44,000 44,000 54,500 54,500
C.O.P. (47°F) 3.8 3.8 3.8 3.8 3.6 3.6
BTU/h (17°F) 21,600 21,600 26,000 26,000 33,800 33,800
C.O.P. (17°F) 2.4 2.4 2.4 2.4 2.5 2.5
HSPF 8.0 8.0 8.0 8.0 8.0 8.0
Type EEM EEM EEM EEM EEM EEM
Wheel (D x W) 10 x 8 10 x 8 10 x 8 10 x 8 11 x 8 11 x 8
Cooling CFM 1,300 1,300 1,600 1,600 1,700 1,700
Fan-Only CFM 1,200 1,200 1,400 1,400 1,600 1,600
RLA 2.9 2.9 2.9 2.9 2.9 2.9
No. of Speeds 5 5 5 5 5 5
Horsepower - RPM ½ - 1,050 ½ - 1,050 ¾ - 1,050 ¾ - 1,050 ¾ - 1,050 ¾ - 1,050
Face Area (
2
) 6.2 6.2 6.2 6.2 7.0 7.0
Rows Deep/ Fins per Inch 4/ 14 4/ 14 4/ 14 4/ 14 4/ 14 4/ 14
Indoor Metering Device Size 0.072 0.074 0.076 0.076 0.088 0.088
Filter Size (
2
) (2) 20x20x1 (2) 20x20x1 (2) 20x20x1 (2) 20x20x1 (2) 20x25x1 (2) 20x25x1
Drain Size (NPT) ¾" ¾" ¾" ¾" ¾" ¾"
Refrigerant Charge (oz.) 150 140 190 190 200 200
Horsepower - RPM ¼ - 1075 ¼ - 1075 ¼ - 1075 ¼ - 1075 ¼ - 1075 ¼ - 1075
RLA/LRA 1.4 / 2.9 1.4 / 2.9 1.4 / 2.9 1.4 / 2.9 1.4 / 2.9 1.4 / 2.9
Fan Diameter / # Fan Blades 22 / 4 22 / 4 22 / 4 22 / 4 22 / 4 22 / 4
Face Area (
2
) 17 17 19.1 19.1 19.1 19.1
Outdoor Metering Device Size 0.065 0.065 0.065 0.062 0.071 0.071
Rows Deep/ Fins per Inch 1 / 24 1 / 24 2 / 16 2 / 16 2 / 16 2 / 16
Quanty / Type 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single
Compressor RLA/LRA 17.9 / 112 17.9 / 112 19.9 / 109 19.9 / 109 26.4 / 134 26.4 / 134
Voltage/Phase/ Frequency 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
Indoor Blower FLA 2.9 2.9 2.9 2.9 2.9 2.9
Outdoor Fan RLA 1.4 1.4 1.4 1.4 1.4 1.4
Total Unit Amps 22.2 22.2 24.2 24.2
30.7 30.7
Min. Circuit Ampacity¹ 26.6 26.6 29.2 29.2 40.2 40.2
Min. Overcurrent Protecon (amps)² 40 40 45 45 60 60
375 / 385 375 / 385 405 / 415 405 / 415 405 / 415 405 / 415
¹ Wire size should be determined in accordance with Naonal Electrical Codes. Extensive wire runs will require larger wire sizes.
² Must use me-delay fuses or HACR-type circuit breakers of the same size as noted.
Always check the S&R plate for electrical data on the unit being installed.