GPH16 Horizontal Spec Sheet

26 www.goodmanmfg.com SS-GPH16H
SS-GPH16H www.goodmanmfg.com 27
SEE NOTE 2
SEE NOTE 3
EM
TR
208-230
3
240
208-230/1/60
SUPPLY VOLTAGE
C
COMP
C
S.A.
S
T1
R
L1
DF1
C
SEE NOTE 4
H
F
RCCF
CM
HVDR
T2
C
DF2
L2
H
RCCF
F
C
BR
PU
2
24V
208
TR
C
BK
1
PU
COMP
CM
BR
BR
PU
41
PLF
PU
BK
YL
S
BK
RD
BK
5
6
2
3
CR
LVJB
RD
OR
BL
BR
WH
GR
PU
R
O
C
W2
W1
G
Y1
A
T
O
T
S
M
R
E
H
T
T2
T1
RD
BL
SEE NOTE 3
PU
BL
L1
GND
C
L2
BK
60
/
/
1
0
3
2
-
8
0
2
7
8
9
BL
BR
0140G03658-B
RD
RD
BK
BK
RD
PU
C L G N
1
2 3
BL
BL
RD
GR
GR
RD
EM
GR
SEE NOTE 2
DFT
RVC
SEE
NOTE 5
N
1 3
2
L
G
NOTES:
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS
ORIGINAL (AT LEAST 10C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE YELLOW AND WHITE
LEADS FROM EM"2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE
ENERGIZED, THE HIGHER SPEED SETTING IS USED.
3 FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
4. START ASSIST FACTORY EQUIPPED WHEN REQUIRED
5. USE COPPER CONDUCTORS ONLY
USE N.E.C. CLASS 2 WIRE
6. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY
EQUIPPED WHEN REQUIRED.
7. DOUBLE POLE CONTACTOR SHOWN. SINGLE POLE CONTACTOR
COULD BE FACTORY EQUIPPED AS AN ALTERNATE CONFIGURATION.
8. COMMON SIDE OF CONTACTOR CAN NOT BE GROUNDED OR
CONNECTED TO ANY OTHER COMMON (24V).
SEE NOTE 1
SA
SEE NOTE 4
RD
YL
BK
OR
GR
4 5
HPS
CH
CHS
LPS
YL/PK
PU
R
D
RD
C
H
S
C
H
GR
BK
BK
BK
BK
PU
BK
P
U
PU
B
L
/P
K
B
L
/P
K
P
U
R
W
2
O
W
1
Y
1
G
C
4
5
6
P
L
F
E
M
1
C
H
P
S
C
T
H
E
R
M
O
S
T
A
T
2
3
S
E
E
N
O
T
E
2
2
4
V
D
C
D
F
T
Y
C
R
R
V
C
L
P
S
C
N
T
R
-
P
S
1
P
S
2
R
W
O
R
-
D
F
T
D
F
T
O
-
R
V
C
-
R
V
P
U
2
P
O
L
E
O
N
L
Y
S
E
E
N
O
T
E
7
P
U
P
U
B
L
SEE NOTE 6
SEE NOTE 6
SEE NOTE 6
R
D
R
D
P
U
W
H
B
L
O
R
C
O
N
T
R
O
L
B
O
X
Y
L
S
E
E
N
O
T
E
7
S
E
E
N
O
T
E
8
Y
L
W
H
W
H
W
H
B
K
B
K
B
K
P
U
P
U
P
U
Y
L
R
D
B
L
Y
L
O
R
Y
L
/P
K
PS2
C
C
R
C
Y
Y
R-PS1
R-DFT
DFT
0
CNT
CCR
HVDR
LVDR
W
C-RV
0-RV
0
DF2
DF1
R
D
C
G
R
R
D
R
D
R
D
W
H
R
D
Y
L
Y
L
W
H
B
K
B
K
COMPONENT LEGEND
C
CCR
CH
CHS
CM
COMP
DC
DFT
EM
GND
HVDR
LPS
LVDR
LVJB
PLF
RVC
RCCF
SA
TR
HPS
CSR
SOL
CONTACTOR
COMPRESSOR CONTACTOR RELAY
CRACKCASE HEATER
CRACKCASE HEATER SW ITCH
CONDENSER MOTOR
COMPRESSOR
DEFROST CONTROL
DEFROST THERMOSTAT
EVAPORATOR MOTOR
EQUIPMENT GROUND
HIGH VOLTAGE DEFROST RELAY
LOW PRESSURE SWITCH
LOW VOLTAGE DEFROST RELAY
LOW VOLTAGE JUNCTION BOX
FEMALE PLUG / CONNECTOR
REVERSING VALVE COIL
RUN CAPACITOR FOR
COMPRESSOR AND FAN
START ASSIST
TRANSFORMER
HIGH PRESSURE SWITCH
COMPRESSOR SOLENOID RELAY
HI STAGE SOLENOID
FACTORY WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH
VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
WIRE CODE
BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PU PURPLE
RD RED
WH WHITE
YL YELLOW
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION
EQUIPMENT GROUND
FIELD GROUND
FIELD SPLICE
SWITCH (TEMP)
IGNITER
SWITCH (PRESS.)
OVERCURRENT
PROT. DEVICE
JUNCTION
TERMINAL
INTERNAL TO
INTEGRATED CONTROL
PLUG CONNECTION
S
E
E
N
O
T
E
5
Y
2
S
O
L
C
S
R
3
1
4
2
Y
L
Y
L
Y
L
Y
L
Y
L
Y
L
Y
L
Y
2
Y
L
Y
L
B
L
B
L
B
L
B
L
Y
L
Y
L
Y
L
S
E
E
N
O
T
E
1

     

Warning
High Voltage:           

Wiring Diagram ― GPH1642H41B* - GPH1660H41**