AIR FLOW DATA
4646
Horizontal Position Motor sp Volts
Model
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
T1 230 CFM
671 616 567
Watts
51 57 72
T2/T3 230 CFM
941 872 777 746 614
Watts
105 112 113 128 138
T4/T5 230 CFM
1347 1315 1256 1194 1152 1096 1051 972 891
Watts
239 256 265 271 282 286 293 297 305
Dow nshot Position
Motor sp Volts Static
Model
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
T1 230 CFM
699 595 523
Watts
57 61 72
T2/T3 230 CFM
919 855 782 695 631 578 523
Watts
108 117 121 132 143 144 149
T4/T5 230 CFM
1312 1275 1216 1153 1096 1028 943 869 816
Watts
260 269 274 285 295 300 304 310 316
Horizontal Position Motor sp Volts Static
Model
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
T1 230 CFM
743 707 595 513
Watts
61 73 77 85
T2/T3 230 CFM
1146 1098 1044 991 934 817 764 698 653
Watts
157 170 176 186 194 201 210 215 215
T4/T5 230 CFM
1440 1418 1364 1307 1265 1219 1168 1094 1049
Watts
290 306 312 321 326 332 348 353 360
Dow nshot Position
Motor sp Volts Static
Model
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
T1 230 CFM
722 672 574 509
Watts
60 74 80 89
T2/T3 230 CFM
1103 1038 978 922 806 731 676 622 564
Watts
162 168 179 188 199 205 208 214 219
T4/T5 230 CFM
1401 1357 1305 1244 1179 1118 1046 934 884
Watts
311 326 318 334 341 349 353 352 357
Horizontal Position Motor sp volts Static
Model
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
T1 230 CFM
846 762 716 585 519
Watts
74 83 94 98 108
T2/T3 230 CFM
1278 1214 1182 1129 1072 1013 950 853 788
Watts
221 218 232 245 253 264 265 275 272
T4/T5 230 CFM
1604 1560 1507 1468 1415 1364 1321 1276 1218
Watts
396 402 408 424 426 423 444 454 454
Dow nshot Position Motor sp Volts Static
Model
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
T1 230 CFM
809 730 623 542 485 441
Watts
73 85 92 98 107 112
T2/T3 230 CFM
1284 1223 1175 1097 1031 974 871 804 761
Watts
220 227 241 247 255 262 272 277 285
T4/T5 230 CFM
1578 1539 1498 1452 1396 1332 1279 1224 1161
Watts
401 409 421 425 438 439 452 453 455
GPH1636M41* GPH1636M41*
Static
GPH1624M41* GPH1624M41*GPH1630M41*GPH1630M41*