GPH16M Service Manual

AIR FLOW DATA
4545
MODEL
SWITCH
3
SWITCH
4
THERMOSTAT
N/A ON Single Stage
N/A OFF Two-Stage
APH 16* *
CFM
SWITCH
7
SWITCH
8
+10% On Off
Normal Off Off
-10% Off On
DIP Switch Settings
for Single and Two-Stage Thermostats
Adjustments Through Dip Switch Combinations
7-8
MODEL
SPEED
TAP
SWITCH
1
SWITCH
2
ELECTRIC
HEAT (CFM)
A
Off Off
1050
(F)
B
On Off 950
C
Off On 825
D
On On 700
A
Off Off
1250
(F)
B
On Off 1100
C
Off On 1000
D
On On 800
A
Off Off
1250
(F)
B
On Off 1100
C
Off On 1000
D
On On 800
A
Off Off 1800
B
On Off 1700
C
Off On
1400
(F)
D
On On 1225
A
Off Off
1800
(F)
B
On Off 1700
C
Off On 1400
D
On On 1225
A
Off Off
2000
(F)
B
On Off 1850
C
Off On 1600
D
On On 1350
(F)
Factory Setting
APH1624
APH1630
APH1642
APH1648
APH1636
APH1660
MODEL
SPEED
TAP
SWITCH
5
SWITCH
6
COOLING/HP
CFM
A
Off Off
1050
(F)
B
On Off 950
C
Off On 825
D
On On 700
A
Off Off
1250
(F)
B
On Off 1100
C
Off On 1000
D
On On 800
A
Off Off
1250
(F)
B
On Off 1100
C
Off On 1000
D
On On 800
A
Off Off 1800
B
On Off 1700
C
Off On
1400
(F)
D
On On 1225
A
Off Off
1800
(F)
B
On Off 1700
C
Off On 1400
D
On On
1225
(F)
A
Off Off
2000
(F)
B
On Off 1850
C
Off On 1600
D
On On 1350
(F)
Factory Setting
APH1660
APH1624
APH1630
APH1636
APH1642
APH1648