GPUM3 Spec Sheet
2 www.goodmanmfg.com SS-GPUM3
SS-GPUM3 www.goodmanmfg.com 3
GPUM3
2404041
GPUM3
3006041
GPUM3
3606041
GPUM3
4208041
GPUM3
4808041
GPUM3
6108041
Total BTU/h 23,000 28,600 34,200 40,000 46,250 56,000
Sensible BTU/h 18,800 23,080 28,160 30,980 36,190 43,175
SEER2 / EER2 13.4 / 10.6 13.4 / 10.6 13.4 / 10.6 13.4 / 10.6 13.4 / 10.6 13.4 / 10.6
Decibels 78 78 78 78 80 79
AHRI Reference #s 209319523 209319529 209319535 209319541 209319547 209319553
Input BTU/h 40,000 60,000 60,000 80,000 80,000 80,000
Output BTU/h 32,400 48,600 48,600 64,800 64,800 64,800
AFUE 81 81 81 81 81 81
Temperature Rise Range 20 - 50 30 - 60 30 - 60 30 - 60 30 - 60 30 - 60
No. of Burners 1 1 1 1 1 1
Type ECM ECM ECM ECM ECM ECM
Wheel (D x W) 10” x 8” 10” x 8” 10" x 9" 11” x 10” 11” x 10” 11” x 10”
Indoor Nominal CFM 800 1,000 1,200 1,300 1,525 1325 L / 1700 H
No. of Speeds 5 5 5 5 5 5
Horsepower 1/2 1/2 1/2 3/4 3/4 1
Face Area (²) 4.35 4.35 4.35 5.68 5.68 5.68
Rows Deep/Fins per Inch 3/14 3/14 4/14 4/14 4/14 4/14
Piston Size (Cooling) 0.057 0.062 0.068 0.072 5.68 5.68
Drain Size (NPT) ¾” ¾” ¾” ¾” ¾” ¾”
Refrigerant Charge (oz.) 75 78 92 103 107 100
Horsepower - RPM 1/6 - 815 1/4 - 1,075 1/4 - 1,075 1/4 - 1,075 1/3 - 1,122 1/3 - 1,122
Diameter / # of Blades 22” / 3 22” / 3 22" / 3 22” / 3 22” / 3 22” / 3
Outdoor Nominal CFM 2,150 3,050 2,850 3,300 3,000 3,000
Face Area (²) 12.29 12.29 11.13 15.36 14.37 14.37
Rows Deep/Fins per Inch 1/27 1/24 2/27 1/24 2/27 2/27
Quanty / Type 1 / Scroll 1 / Scroll 1 / Scroll 1 / Scroll 1 / Scroll 1 / Scroll
Stage Single Single Single Single Single Two
Compressor RLA/LRA 13.5 / 58.3 14.1 / 73 14.1/77.0 17.9 / 112 19.9 / 110.00 25.6 / 158.0
Voltage-Phase (Frequency 60Hz) 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1
Indoor Blower FLA 3.8 3.8 3.8 5.4 5.4 7.0
Outdoor Fan FLA/LRA 0.95/2.0 1.4 / 3.2 1.4 / 3.2 1.4 / 3.2 2.0 / 4.4 2.0 / 4.4
Min. Circuit Ampacity 21.6 22.8 22.8 29.2 32.3 41
Max. Overcurrent Protecon 35 amps 35 amps 35 amps 45 amps 50 amps 60 amps
Entrance Size Power Supply 1⅛” 1⅛” 1⅛” 1⅛” 1⅛” 1⅛”
Entrance Size Control Voltage ⅞” ⅞” ⅞” ⅞” ⅞” ⅞”
412 / 435 420 / 442 496 / 520 523 / 545 533 / 555 533 / 555
¹ Wire size should be determined in accordance with Naonal Electrical Codes. Extensive wire runs will require larger wire sizes.
² Must use me-delay fuses or HACR-type circuit breakers of the same size as noted.
Always check the S&R plate for electrical data on the unit being installed.