Service Instructions
SERVICING
97
- Connectors are oriented "down" 
(
or as recommended b
y
 equipment manufacturer
)
.- Arran
g
e harnesses with "drip loop" under motor.
- 
I
s con
d
ensa
t
e 
d
ra
i
n p
l
u
gg
e
d?
- 
Ch
ec
k
f
or 
l
ow a
i
r
fl
ow 
(t
oo muc
h
l
a
t
en
t
 capac
ity)
.
- 
Check
for
undercharged
condition
. - 
Check
and
plug
leaks
in
return
ducts
, 
cabinet
.
*Moisture Check
I
mpor
t
an
t
N
o
t
e:
U
s
i
n
g
th
e wron
g
 mo
t
or
/
con
t
ro
l
 mo
d
u
l
e vo
id
s a
ll
 pro
d
uc
t
 warran
ti
es an
d
 ma
y
 pro
d
uce unexpec
t
e
d
 resu
lt
s. 
Note: 
You must use the correct replacement control/motor module since the
y
 are factor
y
 pro
g
rammed for specific operatin
g
 modes. Even thou
g
h the
y
 look alike, different modules ma
y
 have completel
y
 different 
functionality. The ECM variable speed motors are c
Symptom Fault Description(s) Possible Causes Corrective Action Cautions and Notes
 - Motor rocks
 slightly 
 w hen starting.
 - This is normal start-up for
 variable speed motor.
---- ---- ----
 - No movement.
 - Manual disconnect sw itch off or
 door sw itch open.
 - Blow n fuse or circuit breaker.
 - 24 Vac w ires misw ired.
 - Unseated pins in w iring 
 harness connectors.
 - Bad motor/control module.
 - Moisture present in motor or control module.
 - Check 230 Vac pow er at motor.
 - Check low  voltage (24 V ac R to C) at motor.
 - Check low  voltage connections
 (G, Y, W, R, C) at motor.
 - Check for unseated pins in connectors 
 on motor harness.
 - Test w ith a temporary jumper betw een R - G.
 - 
 - Turn pow er OFF prior to repair. 
 Wait 5 minutes after 
 disconnecting pow er before
 opening motor. 
 - Handle electronic motor/control w ith care.
 - Motor rocks,
 but w on't start.
 - Loose motor mount.
 - Blow er w heel not tight on motor shaft.
 - Bad motor/control module.
 - Check for loose motor mount.
 - Make sure blow er w heel is tight on shaft.
 - Perform motor/control replacement check,
 ECM motors only.
 - Turn pow er OFF prior to repair. 
 Wait 5 minutes after 
 disconnecting pow er before
 opening motor. 
 - Handle electronic motor/control w ith care.
 - Motor 
 oscillates up & 
 dow n w hile
 being tested 
 off of blow er.
 - It is normal for motor to
 oscillate w ith
 no load on shaft.
---- ---- ----
 - Varies up and dow n
 or intermittent.
 - Variation in 230 Vac to motor.
 - Unseated pins in w iring harness 
 connectors.
 - Erratic CFM c ommand f rom
 "BK" terminal.
 - Improper thermostat connection or setting.
 - Moisture present in motor/control module.
 - Check line voltage for variation or "sag".
 - Check low  voltage connections
 (G, Y, W, R, C) at 
 motor, unseated pins in motor
 harness connectors. 
 - Check-out system controls - Thermostat.
 - Perform Moisture Check.*
 - Turn pow er OFF prior to repair.
 - "Hunts" or "puffs" at
 high CFM (speed).
 - Incorrect or dirty filter(s).
 - Incorrect supply or return ductw ork.
 - Incorrect blow er speed setting.
 - Does removing panel or filter
 reduce "puffing"?
 - Check/replace filter.
 - Check/correct duct restrictions.
 - Adjust to correct blow er speed setting.
 - Turn pow er OFF prior to repair.
Troubleshooting Chart for GE/Regal-Beloit ECM Variable Speed Air Circulator Blower Motors
 - Motor w on't
 start.
 - Motor starts,
 but runs 
 erratically.
CHART CONTINUED ON NEXT PAGE