Installation Manual

11
Pipe and Combustion Air Pipe for details concerning the

connections.
When using the horizontal alternate vent conguration,
you must use the RF000142 vent drain kit. See following
illustration.






This furnace has provisions allowing for electrical and gas line
connections through either side panel. In horizontal applica-
tions the connections can be made either through the “top” or
“bottom” of the furnace.

A drain pan must be provided if the furnace is installed above
a conditioned area. The drain pan must cover the entire area


Refer to Horizontal Applications and Conditions - Drain
Trap and Lines.
WARNING
P
OSSIBLE
PROPERTY
DAMAGE
,
PERSONAL
INJURY
OR
DEATH
MAY
OCCUR
IF
THE
CORRECT
CONVERSION
KITS
ARE
NOT
INSTALLED
. T
HE
APPROPRIATE
KITS
MUST
BE
APPLIED
TO
ENSURE
SAFE
AND
PROPER
FURNACE
OPERATION
. A
LL
CONVERSIONS
MUST
BE
PERFORMED
BY
A
QUALIFIED
INSTALLER
OR
SERVICE
AGENCY
.
High
Stage
Low
Stage
Natural None
#45 3.5" w.c. 1.9" w.c. None
Propane
LPM-07*
1
1.25mm 10.0" w.c. 6.0" w.c. None
Gas
Altitude
Kit
Orifice
Manifold Pressure
Pressure
Switch
Change
0-7000
1
LPM-07* supports both Honeywell and White-Rodgers 1-stage valves
NOTE: In Canada, gas furnaces are only certified to 4500 feet.


gas at standard altitude. Propane gas installations require an
-

High altitude installations may require both a pressure

necessary to compensate for the natural reduction in the
density of both the gas fuel and the combustion air at
higher altitude.

-

-
ommended that a LPLP03 kit also be installed. The use of

supply pressure is too low to support proper combustion.
Contact the distributor for a tabular listing of appropriate
manufacturer’s kits for propane gas and/or high altitude
installations. The indicated kits must be used to insure
safe and proper furnace operation. All conversions must
