Use and Care Manual

SS-GARUF www.goodmanmfg.com 3
ARUF
25B14*
ARUF
29B14*
ARUF
31B14*
ARUF
37C14*
ARUF
43C14*
ARUF
49C14*
ARUF
37D14*
ARUF
43D14*
ARUF
47D14*
ARUF
49D14*
ARUF
61D14*

Cooling (Btu/h) 24,000 25,000 30,000 36,000 42,000 48,000 36,000 42,000 43,000 48,000 60,000
Piston Size 0.051 0.057 0.065 0.072 0.076 0.080 0.072 0.076 0.076 0.080 0.080

Diameter 9½" 9½" 9½" 10⅝" 10⅝" 10⅝" 10⅝" 10⅝" 10⅝" 10⅝" 11
15
/
16
"
Width 6" 6" 6" 8" 8" 10⅝" 10⅝" 10⅝" 10⅝" 10⅝" 10⅝"

Liquid
⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Sucon
¾" ¾" ⅞" ⅞" ⅞" ⅞" ⅞" ⅞" ⅞" ⅞" ⅞"
Coil Drain Connect (FPT)
¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾"

Voltage 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230
Min Circuit Ampacity 2.4/2.4 2.4/2.4 2.4/2.4 4/4 4/4 4/4 4/4 4/4 4/4 4/4 6/6
Max. Overcurrent Device (Amps) 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15
Minimum VAC
197 197 197 197 197 197 197 197 197 197 197
Maximum VAC
253 253 253 253 253 253 253 253 253 253 253

Full Load Amps (FLA)
1.9 1.9 1.9 3.0 3.0 3.1 3.0 3.5 3.5 3.5 4.6
Horsepower (HP)
½ ½ ½ ½ ¾

100 100 110 130 130 135 140 145 150 145 155
 For a properly matched system and piston sizing informaon, refer to Amana piston kit chart of the corresponding Amana® outdoor unit.
Minimum Circuit Ampacity (MCA) and Maximum Overcurrent Protecon (MOP) for blower without supplemental heat installed.
Refer to unit nameplate and/or Heat Kit Data for specicaon with approved accessory heaters installed.
Product Specifications