Service Manual

PRODUCT IDENTIFICATION
28
Split System Condensers
Model/Rev Description
GSX160**1FA Initial release of the Goodman 16 SEER R410A Condensers.
GSX160611FA New high capacity 5 ton model that will supplement the current GSX160601 models.
GSX160[18-61]1FB Minor revision for GSX16s to include ball valves 0151R00045 and 0151R00046.
GSX160601GA 7mm coils.
GSX160(48/60/61)1FB Ball valve change from 0151R00046 to 0151R00081
GSX160(18/24/30/36)1FC Migrating from copper to aluminum motors.
GSX160(18/24/30/36)1FC
GSX160(42/48/60/61)1FC
Ball Valve Re-work 0151R00045 & 0151R00046
GSX160311AA
GSX160371AA
Initial release creates and launches 2 new SKUs in the 16 SEER single-stage AC
product line.
GSX160[24, 30, 60]1FE
Refrigerant charge reduction.
GSX160[31,37]1AB
Equivalent motor with Aluminum Windings replacing Copper Windings.
GSX160[18,36,42,48,61]1FE
GSX160[24,30]1FF
GSX160[31,37]1AC
Switching current Goodman 16SEER condensers and heat pumps with grille tops to
louver tops to be consistent with other Goodman units having louver-style top
panels.
GSX160[48,61]1FF Create new Motor 0131M00807 & Replace 0131M00061 with 0131M00807
GSX160421FG
GSX160481FH
Change from copper wound compressor motor to aluminum wound compressor motor.
ZP34K5EPFV130 and ZP36K5EPFV130.
GSX16S[18-48]1AA
GSX16A[18-60]1AA
Releasing new top level nomenclature for the 16 SEER condenser family. The "0" that
previously followed the GSX16 family name (preceding the nominal capacity digits) will now
be used to designate the region the product can be sold in (A=All Regions, N=North only,
S=Southeast & North).
GSX16
GOODMAN BRAND SPLIT X-R410A CONDENSERS 15 AND 16 SEER