Model # Description
VSX130[18-48]1AA
Value Split X condensing units, 13 Seer R410A condensing units. Introduces Value
Line 13 SEER condensing units with R-410A.
VSX130611AA
V
alue Split X condensing units, 13 Seer R410A condensing units. Supplements the 5
ton model GSX130611 to enhance performance.
VSX130301AB
V
alue Split X condensing units, 13 Seer R410A condensing units: replacing the fan
motor to -294 and fan blade to -18 on the VSX130301AA.
VSX130301AC
V
alue Split X condensing units, 13 Seer R410A condensing units: changing from the
current four piece louver assembly, to a two piece louver plus a corner post on
Goodman and value series 26" and 29" chassis.
VSX130[42-48]1AB
V
alue Split X condensing units, 13 Seer R410A condensing units: replacing
with 6-pole motor and Copeland compressor.
VSX130[42-48]1AC
V
alue Split X condensing units, 13 Seer R410A condensing units: changing from the
current four piece louver assembly, to a two piece louver plus a corner post on
Goodman and value series 26" and 29" chassis.
VSX130181BA
V
alue Split X condensing units, 13 Seer R410A condensing units. Introduces Value
Line 13 SEER 1.5 ton condensing units with R-410A, with rotary compressors
VSX130181EA
VSX130181EB
V
alue Split X condensing units, 13 Seer R410A condensing units. Introduction of 1.5
ton condenser with Rechi Compressor.
VSX130181ED
V
alue Split X condensing units, 13 Seer R410A condensing units. Introduction of Rev
ED. This involves changing from 4 leg Rechi Compressor 50N382XV-ZAKM to 3 Leg
Rechi Compressor 50N382XV-5AKM and change in Suction line Assy from
0210R01608 to 0210R01406. This minor rev change also would include revising
quantity of both Grommet (60140209) & Screw (0163M00186) from 4pcs to 3pcs.
VSX130241BA
V
alue Split X condensing units, 13 Seer R410A condensing units. Introduces Value
Line 13 SEER 2.0 ton condensing units with R-410A, with aluminum coils, aluminum
manifolds w/existing scroll compressor.
VSX130361BA
V
alue Split X condensinb units 13 Seer R410A condensing units. 13 SEER R-410A
Condensers: replacing current compressor with compressor ZP29K5EPFV130.
VSX130361EB
V
alue Split X condensinb units 13 Seer R410A condensing units. 13 SEER R-410A
Condensers: changing from the current four piece louver assembly, to a two piece
louver plus a corner post on Goodman and value series 26" and 29" chassis.
VSX130601BA
V
alue Split X condensing units, 13 Seer R410A condensing units. Introduces Value
Line 13 SEER condensing units with R-410A, using SmartCoil® coils.
VSX130601BB
V
alue Split X condensing units, 13 Seer R410A condensing units. Changing from the
current four piece louver assembly, to a two piece louver plus a corner post on
Goodman and value series 26" and 29" chassis.
VSX130421BA
VSX130481BA
V
alue Split X condensing units, 13 Seer R410A condensing units. Introduction of Value
Line 3.5 and 4 ton 13 SEER condensing units with reciprocating compressor.
VSX130[18-36]1DA
V
alue Split X condensing units, 13 Seer R410A condensing units. Introduction of Value
Line 3.5 and 4 ton 13 SEER Condensers conversion to 23" chassis for the 1.5 - 3 ton
models.
VSX130301DB
V
alue Split X condensing units, 13 Seer R410A condensing units. Introduction of Value
Line 2.5 13 SEER Condensers with improved coil circuit assembly for greater
capacity/efficiency and the creation of a new discharge tubing assembly.
VSX130301EA
V
alue Split X condensing units, 13 Seer R410A condensing units. Introduction of Value
Line 3 Ton 13 SEER Condensers release of 3 ton models converting from 29" chassis
to 26" chassis.
VSX130241EA
V
alue Split X condensing units, 13 Seer R410A condensing units. Introduction of Value
Line 2.0 Ton 13 SEER Condensers with Rechi Compressor, converting 23" chassis to
26" chassis
VSX130371AA
V
alue Split X condensing units, 13 Seer R410A condensing units. Introduction of Value
Line 2.5 13 SEER Condensers with improved decibel ratings for Canadian market.
VSX130241EB
V
alue Split X condensing units, 13 Seer R410A condensing units. Change made due
to all 3 compressor wires yellow, red and black changing from 40" to 45".