GSX14 Service Manual

217
WIRING DIAGRAMS
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
ASX130[24-48]1CC / ASX130601CB/ ASX130611A*
/ ASX130[18, 36]1D*
T1
L1
T2
L2
ALTERNATE DOUBLE
POLE CONTACTOR
SCR
BK
RD
YL
Y
C
CADM
BL
YL
RD
BK
YL
CONTROL BOX
SC
YL
BL
YL
RD
BK
MAIN
COMP
IO
CM
AUX
MAIN
BK
BR
PU
SR
5
2
1
BK
YL
BL
YL
C
IO
R
S
AUX
COMP
ALTERNATE DOUBLE
POLE CONTACTOR ONLY
IO
T1
C
M
A
I
N
R
A
U
X
5
S
SR
CADM
SA
2
1
RCCF
SC
T2
C
L1
L2
(IF USED)
CH
C
C
A
D
M
CADM
F
C
A
D
M
M
A
I
N
A
U
X
IO
CM
C
Y
C
Y
C
BL
YL
C
Y
LV J B
NOTE 1
COMPONENTCODE
C --------------- CONTACTOR
CADM -------- COMFORT ALERT MODULE
CM ------------ OUTDOOR FAN MOTOR
COMP -------- COMPRESSOR
IO -------------- INTERNAL OVERLOAD
LVJB ---------- LOW VOLTAGE JUNCTION BOX
RCCF --------- RUN CAPACITOR FOR COMPRESSOR & FAN
SA ------------- START ASSIST
SC ------------- START CAPACITOR FOR COMPRESSOR
(
OPTIONAL
)
SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL)
CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.
OUTDOOR POWER SUPPLY
SEE RATING PLATE
WIRING CODE
FA CTORY WIRING
HIGH VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH VOLTAGE
FIEL
D WIRING
HIGH VOLTAGE
LOW VOLTAGE
LVJB
RD BL
RD
BL
RD
RD
BKBK
BK
C
T1
L1
T2
L2
RCCF
F
C
HERM
YL
YL
YL
BR
RD
PU
YL
RD
EQUIPMENT GROUND
COLOR CODE
BK --------------- BLACK
BL --------------- BLUE
BR --------------- BROWN
OR --------------- ORANGE
PU --------------- PURPLE
RD --------------- RED
WH -------------- WHITE
YL --------------- YELLOW
RD
SA
(IF USED)
NOTE 2
NOTE 3
IO
0140R00239-A
USE N.E.C.
CLASS 2 WIRE
NOTES:
1) TO INDOOR UNIT LOW VOLTAGE
TERMINAL BLOCK & INDOOR
THERMOSTAT.
2) START ASSIST FACTORY
EQUIPPED WHEN REQUIRED.
3) USE COPPER CONDUCTORS
ONLY.