GSX14 Service Manual

SERVICING
72
Submenu Item Indication (for Display Only; not User Modifiable)
Electric Heat Size (HTR KW) Displays the size in kW of the selected electric heaters.
Motor HP (1/2, 3/4, or 1 MTR HP) Displays the indoor blower motor horsepower.
Heat ON Delay (HT ON) Displays the electric heat indoor blower ON delay.
Heat OFF Delay (HT OFF) Displays the electric heat indoor blower OFF delay.
CONFIGURATION
Submenu Item Indication/User Modifiable Options Comments
Fault 1 (FAULT #1) Most recent fault For display only
Fault 2 (FAULT #2) Next most recent fault For display only
Fault 3 (FAULT #3) Next most recent fault For display only
Fault 4 (FAULT #4) Next most recent fault For display only
Fault 5 (FAULT #5) Next most recent fault For display only
Fault 6 (FAULT #6) Least recent fault For display only
Clear Fault History (CLEAR) NO or YES Selecting YESclears the fault
history
NOTE: Consecutively repeated faults are shown a maximum of 3 times
DIAGNOSTICS
Submenu Item Indication (for Display Only; not User Modifiable)
Model Number (MOD NUM) Displays the model number
Serial Number (SER NUM) Displays the serial number (Optional)
Software (SOFTWARE) Displays the application software revision
IDENTIFICATION
Submenu Item User Modifiable Options Comments
Heat Airflow Trim (HT
TRM
)
-10% to +10% in 2% increments,
default is 0%
Trims the electric heating airflow by the
selected amount.
SET-UP
Submenu Item Indication (for Display Only; not User Modifiable)
Mode (MODE) Displays the current operating mode
CFM (CFM) Displays the airflow for the current operating mode
STATUS
AVPTC AND MBVC ADVANCED U SER M ENUS