Submenu Item Indication (for Display Only; not User Modifiable)
Mode (MODE) Displays the current air conditioner operating mode
CFM (CFM) Displays the airflow for the current operating mode
STATUS
Submenu Item User Modifiable Options Comments
Heat Airflow Trim
(HT TRM)
-10% to +10% in 2% increments,
default is 0%
Selects the airflow trim amount; applies to
heat pump only.
Heat ON Delay
(HT ON)
5, 10, or 15 seconds, default is 5
seconds
Selects the indoor blower heat ON delay;
applies to heat pump only.
Heat OFF Delay
(HT OFF)
30, 50, 70, or 90 seconds, default
is 30 seconds
Selects the indoor blower heat OFF delay;
applies to heat pump only.
Defrost Interval
(DEFROST)
30, 60, 90, or 120 minutes, default
is 30 minutes.
Selects the time interval between defrosts;
applies to heat pump only.
Compressor Delay
(CMP DLY)
0, 5, 15, or 30 seconds, default is 5
seconds
Selects the compressor off time after a
reversing valve shift; applies to heat pump
only.
HEAT SET-UP
Submenu Item User Modifiable Options Comments
Cool Airflow Trim
(CL TRM)
-10% to +10% in 2% increments,
default is 0%
Selects the airflow trim amount; applies to air
conditioner only.
Cool Airflow Profile
(CL PRFL)
A, B, C, or D, default is A Selects the airflow profile; applies to air
conditioner only.
Cool ON Delay
(CL ON)
5, 10, 20, or 30 seconds, default is
5 seconds
Selects the indoor blower ON delay; applies
to air conditioner only.
Cool OFF Delay
(CL OFF)
30, 60, 90, or 120 seconds, default
is 30 seconds
Selects the indoor blower OFF delay; applies
to air conditioner only.
Dehumidification Select
(DEHUM)
ON or OFF (default is OFF) Selecting "OFF" disables dehumidification;
selecting "ON" enables dehumidification;
applies to air conditioner only.
COOL SET-UP