GSX14 Service Manual

SERVICING
86
Diagnostic/Status LED Codes
Com f or tNe t ™
Thermostat Only
Symptoms of Abnormal Operation
(Legacy & ComfortNet™ Thermostat)
Green Ye ll ow Red Red Y1
Fault
Description
Message Code
Possible Causes
Corrective Actions Notes & Cautions
Compressor and outdoo r fan are off.
Low pressure and high pressure
switches are closed.
Integrated control module
diagnostic/status LED’s display the
indicated code.
ComfortNet™ thermostat “Call for
Service” icon illuminated.
ComfortNet™ ther mostat scrolls
“Check Air Conditioner” or “Check
Heat Pump” message.
OFF 7
Fl a sh es
OFF ON if call
present;
OFF if no
call
Open Run
Circuit
OPEN RUN 07 Compressor run winding is
open.
Compressor not properly
wired to control.
Fau lty compressor wiring.
Check compressor;
repair/replace as
needed.
Check wiring;
repair/replace as
needed.
Turn power OFF prior
to repair.
Fault will clear after 1
normal cycle.
Fault may be cleared by
cycling 24VAC to
cont rol.
Replace with correct
replacement part(s).
Compressor and outdoo r fan are off.
Low pressure and high pressure
switches are closed.
Open run circuit has been detected 4
times with 5 minute delay between each
detecti on.
Integrated control module
diagnostic/status LED’s display the
indicated code.
ComfortNet™ thermostat “Call for
Service” icon illuminated.
ComfortNet™ ther mostat scrolls
“Check Air Conditioner” or “Check
Heat Pump” message.
OFF 7
Fl a sh es
ON ON if call
present;
OFF if no
call
Open Run
Circuit Lockout
OPEN RUN
LOCK
07 Compressor run winding is
open.
Compressor not properly
wired to control.
Fau lty compressor wiring.
Check compressor;
repair/replace as
needed.
Check wiring;
repair/replace as
needed.
Turn power OFF prior
to repair.
Must clear fault by
cycling 24VAC to
cont rol.
Replace with correct
replacement part(s).
Air conditioner/ heat pump may appear
to be operating normally.
Compressor protector may be open
(compressor and outdoor fan off).
Integrated control module
diagnostic/status LED’s display the
indicated code.
OFF 8
Fl a sh es
OFF ON if call
present;
OFF if no
call
Low Line
Voltage
LOW LINE
VOLT
08 Low line voltage. Check circuit breakers
and fuses.
Verify unit is
connected to power
supply as specified on
rating plate.
Correct low line
voltage condition;
contact local utility if
needed.
Turn power OFF prior
to repair.
Control detects line
voltage less than 185
VAC .
Air conditioner/ heat pump may appear
to be operating normally.
Compressor protector may be open
(compressor and outdoor fan off).
Integrated control module
diagnostic/status LED’s display the
indicated code.
ON 8
Fl a sh es
OFF ON if call
present;
OFF if no
call
High Line
Voltage
HIGH LINE
VOLT
08
High line voltage. Correct high li ne
voltage condition;
contact local utility if
needed.
Verify unit is
connected to power
supply as specified on
rating plate.
Correct low line
voltage condition;
contact local utility if
needed.
Turn power OFF prior
to repair.
Control detects line
voltage greater than 255
VAC .