Installations Instructions

4
SAFETY CONSIDERATIONS
Adhere to the following warnings and cautions when install-
ing, adjusting, altering, servicing, or operating the furnace.
To ensure proper installation and operation, thoroughly read
this manual for specifics pertaining to the installation and
application of this product.
This furnace is manufactured for use with natural gas. It
may be field converted to operate on L.P. gas by using the
appropriate L.P. conversion kit listed in the
PROPANE GAS/
HIGH ALTITUDE INSTALLATIONS section of this manual
Install this furnace only in a location and position as speci-
fied in LOCATION REQUIREMENTS & CONSIDERATIONS sec-
tion and INSTALLATION POSITIONS section of this manual.
Provide adequate combustion and ventilation air to the fur-
nace as specified in COMBUSTION & VENTILATION AIR RE-
QUIREMENTS section of this manual.
Combustion products must be discharged to the outdoors.
Connect this furnace to an approved vent system only, as
specified in VENT/ FLUE PIPE & COMBUSTION AIR PIPE sec-
tion of this manual.
Never test for gas leaks with an open flame. Use a commer-
cially available soap solution made specifically for the detec-
tion of leaks to check all connections, as specified in GAS
SUPPLY AND PIPING section of this manual.
Always install a furnace to operate within the furnace’s in-
tended temperature-rise range with a duct system which has
external static pressure within the allowable range, as speci-
fied on the furnace rating plate and OPERATIONAL CHECKS
section of these instructions.
When a furnace is installed so that supply ducts carry air
circulated by the furnace to areas outside the space contain-
ing the furnace, the return air shall also be handled by duct(s)
sealed to the furnace casing and terminating outside the
space containing the furnace.
A gas-fired furnace for installation in a residential garage
must be installed as specified in the LOCATION REQUIRE-
MENTS AND CONSIDERATIONS section of this manual.
This furnace may be used as a construction site heater only
if certain conditions are met. These conditions are listed in
the PRODUCT APPLICATION section of this manual.
FROZEN AND BURST WATER PIPE HAZARD
F
AILURE
TO
PROTECT
AGAINST
THE
RISK
OF
FREEZING
M AY
RESULT
IN
PROPERTY
DAM AGE
.
S
PECIAL
PRECAUTIONS
M UST
BE
M ADE
IF
INSTALLING
FURNACE
IN
AN
AREA
W HICH
M AY
DROP
BELOW
FREEZING
. T
HIS
CAN
CAUSE
IM PROPER
OPERATION
OR
DAM AGE
TO
EQUIPM ENT
. I
F
THE
FURNACE
ENVIRONM ENT
HAS
THE
POTENTIAL
OF
FREEZING
,
THE
DRAIN
TRAP
AND
DRAIN
LINE
M UST
BE
PROTECTED
. T
HE
USE
OF
ACCESSORY
DRAIN
TRAP
HEATERS
,
ELECTRIC
HEAT
TAPE
AND
/
OR
RV
ANTIFREEZE
IS
RECOM M ENDED
FOR
THESE
INSTALLATIONS
.
CAUTION
T
O
PREVENT
PERSONAL
INJURY
OR
DEATH
DUE
TO
IM PROPER
INSTALLATION
,
ADJUSTM ENT
,
ALTERATION
,
SERVICE
OR
M AINTENANCE
,
REFER
TO
THIS
M ANUAL
. F
OR
ADDITIONAL
ASSISTANCE
OR
INFORM ATION
,
CONSULT
A
QUALIFIED
INSTALLER
,
SERVICER
AGENCY
OR
THE
GAS
SUPPLIER
.
WARNING
I
F
THE
INFORM ATION
IN
THESE
INSTRUCTIONS
IS
NOT
FOLLOW ED
EXACTLY
,
A
FIRE
OR
EXPLOSION
M AY
RESULT
CAUSING
PROPERTY
DAM AGE
,
PERSONAL
INJURY
OR
LOSS
OF
LIFE
.
D
O
NOT
STORE
OR
USE
GASOLINE
OR
OTHER
FLAM M ABLE
VAPORS
AND
LIQUIDS
IN
THE
VICINITY
OF
THIS
OR
ANY
OTHER
APPLIANCE
.
D
O
NOT
TRY
TO
LIGHT
ANY
APPLIANCE
.
D
O
NOT
TOUCH
ANY
ELECTRICAL
SW ITCH
;
DO
NOT
USE
ANY
PHONE
IN
YOUR
BUILDING
.
I
M M EDIATELY
CALL
YOUR
GAS
SUPPLIER
FROM
A
NEIGHBOR
S
PHONE
. F
OLLOW
THE
GAS
SUPPLIER
S
INSTRUCTIONS
.
I
F
YOU
CANNOT
REACH
YOUR
GAS
SUPPLIER
,
CALL
THE
FIRE
DEPARTMENT
.
I
NSTALLATION
AND
SERVICE
M UST
BE
PERFORM ED
BY
A
QUALIFIED
INSTALLER
,
SERVICE
AGENCY
OR
THE
GAS
SUPPLIER
.
W HAT TO DO IF YOU SM ELL GAS:
WARNING
T
HIS
PRODUCT
CONTAINS
OR
PRODUCES
A
CHEM ICAL
OR
CHEM ICALS
W HICH
M AY
CAUSE
SERIOUS
ILLNESS
OR
DEATH
AND
W HICH
ARE
KNOW N
TO
THE
S
TATE
OF
C
ALIFORNIA
TO
CAUSE
CANCER
,
BIRTH
DEFECTS
OR
OTHER
REPRODUCTIVE
HARM
.
WARNING
H
EATING
UNIT
SHOULD
NOT
BE
UTILIZED
W ITHOUT
REASONABLE
,
ROUTINE
,
INSPECTION
,
M AINTENANCE
AND
SUPERVISION
. I
F
THE
BUILDING
IN
W HICH
ANY
SUCH
DEVICE
IS
LOCATED
W ILL
BE
VACANT
,
CARE
SHOULD
BE
TAKEN
THAT
SUCH
DEVICE
IS
ROUTINELY
INSPECTED
,
M AINTAINED
AND
M ONITORED
.
IN
THE
EVENT
THAT
THE
BUILDING
M AYBE
EXPOSED
TO
FREEZING
TEM PERATURES
AND
W ILL
BE
VACANT
,
ALL
W ATER
-
BEARING
PIPES
SHOULD
BE
DRAINED
,
THE
BUILDING
SHOULD
BE
PROPERLY
W INTERIZED
,
AND
THE
W ATER
SOURCE
CLOSED
.
IN
THE
EVENT
THAT
THE
BUILDING
M AY
BE
EXPOSED
TO
FREEZING
TEM PERATURES
AND
W ILL
BE
VACANT
,
ANY
HYDRON IC
COIL
UNITS
SHOULD
BE
DRAINED
AS
W ELL
AND
,
IN
SUCH
CASE
,
ALTERNATIVE
HEAT
SOURCES
SHOULD
BE
UTILIZED
.
WARNING
T
O
PREVENT
POSSIBLE
PROPERTY
DAM AGE
,
PERSONAL
INJURY
OR
DEATH
DUE
TO
ELECTRICAL
SHOCK
,
THE
FURNACE
M UST
BE
LOCATED
TO
PROTECT
THE
ELECTRICAL
COM PONENTS
FROM
W ATER
.
WARNING
Drain trap must be primed at time of installation. Trap is
internally partitioned; add water to both inlet ports until wa-
ter appears at both sides of the outlet opening. Failure to
prime trap at time of installation may have a negative ef-
fect on combustion quality and pressure switch action.