TECHNICAL MANU AL MANUAL TM *CVC96/*MVC96 96% Gas Furnace Units • Refer to Service Manual RS6612010 for installation, operation, and troubleshooting information. • Refer to the appropriate Parts Catalog for part number information. • Models listed on page 3. This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures performed by an unqualified person.
PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information.
PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information.
FURNACE SPECIFICATIONS *MVC96 0403BNA *MVC96 0603BNA *MVC96 0803BNA *MVC96 0804CNA *MVC96 1005CNA *MVC96 1205DNA High Fire Input¹ 40,000 60,000 80,000 80,000 100,000 120,000 High Fire Output¹ 38,400 57,600 76,800 76,800 96,000 115,200 Low-Fire Steady-State Input¹ 28,000 42,000 56,000 56,000 70,000 84,000 Low-Fire Steady-State Output¹ 26,880 40,320 53,760 53,760 67,200 80,640 96 96 96 96 96 96 Temperature Rise Range (°F) 35 - 65 20 - 50 35 - 65 25 - 55 35 - 65 35
FURNACE SPECIFICATIONS *CVC96 0403BNA *CVC96 0603BNA *CVC96 0804CNA *CVC96 1005CNA *CVC96 1205DNA High Fire Input¹ 40,000 60,000 80,000 100,000 120,000 High Fire Output¹ 38,400 57,600 76,800 96,000 115,200 Low-Fire Steady-State Input¹ 28,000 42,000 56,000 70,000 84,000 Low-Fire Steady-State Output¹ 26,880 40,320 53,760 67,200 80,640 96 96 96 96 96 Temperature Rise Range (°F) 20 - 50 35 - 65 25 - 55 45 - 75 35 - 65 Vent Diameter³ 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2"
PRODUCT DIMENSIONS DM96VC AIR DISCHARGE AIR DISCHARG E A 28 ¾ AIR INTAKE 2" PIPE 6½ 2¾ DIMB DISCHARGE 2⅝ C 2 LEFT SIDE DRAIN TRAP EXTERIOR HOLES ¾ 6½ 1⅞ CENTER DIMPLE FOR ALTERNATE AIR INTAKE PIPE 3" OD HOLE HIGH VOLTAGE ELECTRICAL OUTLET ¾ 19½ 2 VENT/FLUE PIPE 2" PVC ALTERNATE VENT/FLUE LOCATION ¾ RIGHT SIDE DRAIN TRAP EXTERIOR HOLES HIGH VOLTAGE ELECTRICAL OUTLE T STANDARD GAS SUPPLY LOCATION ALTERNATE GAS SUPPLY 34 ½ 31 ⅞ 26 ½ 24 ⅞ 23 23 21 ⅛ 19 ⅝ 19 ⅝ SIDE CUT-OUT 14 SIDE CUT
PRODUCT DIMENSIONS TOP VIEW DC96VC FRONT VIEW A 6½ 2⅝ 1⅜ 2½ 1⅝ C 1⅞ 23 1⅞ 1½ RIGHT SIDE VIEW ALTERNATE VENT/ FLUE LOCATION LOW VOLTAGE ELECTRICAL OUTLET LOW VOLTAGE ELECTRICAL OUTLET SIDE CUT-OU T 14 SIDE CUT-OU T ALTERNATE GAS SUPPLY LOCATION ALTERNATE GAS SUPPLY LOCATIO N HIGH VOLTAG E ELECTRICAL OUTLET 25⅛ 34 ½ 25⅛ 14⅞ 14¾ 14¾ 11⅜ 4⅛ LEFT SIDE EXTERIOR DRAIN TRAP HOLE S STANDARD DRAIN TRAP CONNECTION ¾ PVC 11⅜ 6⅞ 6⅞ HIGH VOLTAGE ELECTRICAL OUTLET D FOLDED FLANGES 2 2½ 3½ LE
BLOWER PERFORMANCE SPECIFICATIONS *MVC960403BNA Cooling Speed *MVC960403BNA Heating Speed (@ .1" - .8" w.c. ESP) Tap A B C D (@ .1" - .5" w.c.
BLOWER PERFORMANCE SPECIFICATIONS *MVC960803BNA Cooling Speed *MVC960803BNA Heating Speed ( @ .1" - .8" w.c. ESP) Tap A B C D Tap A B C D (@ .1" - .5" w.c.
BLOWER PERFORMANCE SPECIFICATIONS *MVC961005CNA Cooling Speed *MVC961005CNA Heating Speed ( @ .1" - .8" w.c. ESP) Tap A B C D Tap A B C D (@ .1" - .5" w.c.
BLOWER PERFORMANCE SPECIFICATIONS *CVC960403BNA Cooling Speeds *CVC960403BNA Heating Speed ( @ .1" - .8" w.c. ESP) Tap A B C D Tap A B C D (@ .1" - .5" w.c.
BLOWER PERFORMANCE SPECIFICATIONS *CVC960804CNA Cooling Speeds ( @ .1" - .8" w.c. ESP) Tap A B C D *CVC960804CNA Heating Speed (@ .1" - .5" w.c.
BLOWER PERFORMANCE SPECIFICATIONS *CVC961205DNA Cooling Speeds ( @ .1" - .8" w.c. ESP) Tap A B C D *CVC961205DNA Heating Speed (@ .1" - .5" w.c.
WIRING DIAGRAMS DM96VC/DC96VC HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.