GSZC16 Installation

I
MPORTANT
S
AFETY
I
NSTRUCTIONS
The following symbols and labels are used throughout this manual
to indicate immediate or potential safety hazards. It is the
owner’s and installer’s responsibility to read and comply with all
safety information and instructions accompanying these sym-
bols. Failure to heed safety information increases the risk of
personal injury, property damage, and/or product damage.
S
HIPPING
I
NSPECTION
Always keep the unit upright; laying the unit on its side or top
may cause equipment damage. Shipping damage, and subse-
quent investigation is the responsibility of the carrier. Verify the
model number, specifications, electrical characteristics, and ac-
cessories are correct prior to installation. The distributor or manu-
facturer will not accept claims from dealers for transportation
damage or installation of incorrectly shipped units.
C
ODES
& R
EGULATIONS
This product is designed and manufactured to comply with na-
tional codes. Installation in accordance with such codes and/or
prevailing local codes/regulations is the responsibility of the in-
staller. The manufacturer assumes no responsibility for equip-
ment installed in violation of any codes or regulations. Rated
performance is achieved after 72 hours of operation. Rated per-
formance is delivered at the specified airflow. See outdoor unit
specification sheet for split system models or product specifi-
cation sheet for packaged and light commercial models. Speci-
fication sheets can be found at www.goodmanmfg.com for
Goodman
®
brand products or www.amana-hac.com for Amana
®
brand products. Within either website, please select the
residential or commercial products menu and then select the submenu for the type of product to be installed, such as air
conditioners or heat pumps, to access a list of product pages that each contain links to that model’s specification sheet.
The United States Environmental Protection Agency (EPA) has issued various regulations regarding the introduction
and disposal of refrigerants. Failure to follow these regulations may harm the environment and can lead to the
imposition of substantial fines. Should you have any questions please contact the local office of the EPA.
If replacing a condensing unit or air handler, the system must be manufacturer approved and Air Conditioning, Heating and
Refrigeration Institute (AHRI) matched. NOTE: Installation of unmatched systems is strongly discouraged.
Outdoor units are approved for operation above 55°F in cooling mode. Operation below 55°F in cooling mode requires the use
of an approved low ambient kit.
Operating the unit in a structure that is not complete (either as part of new construction or renovation) will void the warranty.
F
EATURES
This heat pump is a part of the ComfortNet™ family of products. It may be installed as part of a “legacy” system using a
standard 24 VAC thermostat. However, with the CTK0* ComfortNet™ thermostat kit, this heat pump may be installed as part of
a digitally communicating system. The ComfortNet system provides automatic airflow configuration, enhanced setup features,
and enhanced diagnostics. It also reduces the number of thermostat wires to a maximum of four and a minimum of two.
CONDENSING UNIT
HEAT PUMP
INSTALLATION & SERVICE REFERENCE
© 2009-2014 Goodman Manufacturing Company, L.P.
5151 San Felipe, Suite 500, Houston, TX 77056
www.goodmanmfg.com -or- www.amana-hac.com
P/N: IO-348M Date: September 2014
is a registered trademark of Maytag Corporation or its related companies and is used under
license to Goodman Company, L.P., Houston, TX. All rights reserved.
HIGH VOLTAGE!
D
ISCONNECT
ALL
POWER
BEFORE
SERVICING
.
M
ULTIPLE
POWER
SOURCES
MAY
BE
PRESENT
. F
AILURE
TO
DO
SO
MAY
CAUSE
PROPERTY
DAMAGE
,
PERSONAL
INJURY
OR
DEATH
.
WARNING
ONLY
INDIVIDUALS
MEETING
THE
REQUIREMENTS
OF
AN
“E
NTRY
L
EVEL
T
ECHNICIAN
AS
SPECIFIED
BY
THE
A
IR
C
ONDITIONING
, H
EATING
AND
R
EFRIGERATION
I
NSTITUTE
(AHRI)
MAY
USE
THIS
INFORMATION
. A
TTEMPTING
TO
INSTALL
OR
REPAIR
THIS
UNIT
WITHOUT
SUCH
BACKGROUND
MAY
RESULT
IN
PRODUCT
DAMAGE
,
PERSONAL
INJURY
,
OR
DEATH
.
,
AT
A
MINIMUM
,
WARNING
S
CROLL
EQUIPPED
UNITS
SHOULD
NEVER
BE
USED
TO
EVACUATE
THE
AIR
CONDITIONING
SYSTEM
. V
ACUUMS
THIS
LOW
CAN
CAUSE
INTERNAL
ELECTRICAL
ARCING
RESULTING
IN
A
DAMAGED
OR
FAILED
COMPRESSOR
.
CAUTION

Summary of content (24 pages)