GSZC16 Installation
18
TROUBLESHOOTING INFORMATION: UNITARY DIAGNOSTIC CODES
5.)4!29$)!'./34)##/$%3
3YMPTOMSOF
!BNORMAL/PERATION
,EGACY#OMFORT.ET
4HERMOSTAT
$IAGNOSTIC3TATUS
,%$$ISPLAY#ODES &AULT
$ESCRIPTION
#OMFORT.ET
4-
4HERMOSTAT/NLY 0OSSIBLE
#AUSES
#ORRECTIVE
!CTIONS
.OTES
#AUTIONS
$IGIT $IGIT $IGIT -ESSAGE #ODE
s Air conditioner/heat pump
fails to operate.
sIntegrated control module
diagnostic/status LED
display shows the indicated
code.
s#OMFORT.ETTHERMOSTAT
displays error message.
",!.+ d3sConfiguration
Mis-match
).6!,)$
#/.&)'
d3 sShared data sent
to integrated
control module
does not match
hardware
configuration.
sVerify
system type
(communicating
or legacy).
sVerify shared
data is correct
for your specific
model; re-
populate data if
required.
sWire system as
legacy system.
sTurn power OFF prior
to repair.
sUse memory card for
your specific model.
sInsert memory card
BEFORE turning power
/.-EMORYCARDMAY
be removed after data
is loaded. Turn power
OFF before removing
memory card.
sError code will
be cleared once
data is loaded.
Applies only to fully
communicating system
USING#OMFORT.ET
thermostat.
sAir conditioner/heat pump
fails to operate.
sIntegrated control
module diagnostic/status
LED display shows the
indicated code.
s#OMFORT.ETTHERMOSTAT
displays error message.
",!.+ d4s Invalid
Memory
Card Data
).6!,)$
MC DATA
d4 sShared data on
memory card has
been rejected.
sVerify
system type
(communicating
or legacy).
sVerify shared
data is correct
for your specific
model; re-
populate data if
required.
sWire system as
legacy system.
sTurn power OFF prior
to repair.
sUse memory card for
your specific model.
sInsert memory card
BEFORE turning power
/.-EMORYCARDMAY
be removed after data
is loaded. Turn power
OFF before removing
memory card.
sError code will be
cleared once data is
loaded.
s Very long run time.
sFour consecutive
compressor protector
trips with average run
time between trips greater
than 3 hours.
sCompressor operating at
high speed and outdoor fan
operating at low speed
sIntegrated control
module diagnostic/status
LED display shows the
indicated code.
",!.+ 01sLow Side
Fault
LOW SIDE
FAULT
01 sLow refrigerant
charge.
sRestriction in
liquid line.
sIndoor blower
motor failure.
sIndoor
thermostat set
extremely low.
sVerify refrigerant
charge; adjust as
needed.
sCheck for
restricted liquid
line; repair/
replace as
needed.
sCheck indoor
blower motor;
repair/replace as
needed.
sCheck indoor
thermostat setting.
sTurn power OFF prior
to repair.
sFault will clear after 30
consecutive normal
cycles.
sFault may be cleared
by cycling 24VAC to
control.
sReplace with correct
replacement part(s).
sCompressor and outdoor
fan are off.
sThermostat demand is
present.
sIntegrated control
module diagnostic/status
LED display shows the
indicated code.
",!.+ 01sLow Pressure
Cut Out Trip
,03/0%. 01 sLow refrigerant
charge.
sRestriction in
liquid line.
sIndoor blower
motor failure.
sIndoor
thermostat set
extremely low.
sVerify refrigerant
charge; adjust as
needed.
sCheck for
restricted liquid
line; repair/
replace as
needed.
sCheck indoor
blower motor;
repair/replace as
needed.
sCheck low
pressure switch;
repair/replace as
needed.
sCheck indoor
thermostat setting.
sTurn power OFF prior
to repair.
sReplace with correct
replacement part(s).