GSZC16 Installation

23
SPLIT SYSTEMS
AIR CONDITIONING AND HEAT PUMP HOMEOWNER’S ROUTINE MAINTENANCE RECOMMENDATIONS
We strongly recommend a bi-annual maintenance checkup be performed before the heating and cooling seasons begin by a qualified servicer.
Replace or Clean Filter
IMPORTANT NOTE: Never operate unit without a filter installed as dust and lint will build up on internal parts resulting in loss of
efficiency, equipment damage and possible fire.
An indoor air filter must be used with your comfort system. A properly maintained filter will keep the indoor coil of your comfort
system clean. A dirty coil could cause poor operation and/or severe equipment damage.
Your air filter or filters could be located in your furnace, in a blower unit, or in “filter grilles” in your ceiling or walls. The installer
of your air conditioner or heat pump can tell you where your filter(s) are, and how to clean or replace them.
Check your filter(s) at least once a month. When they are dirty, replace or clean as required. Disposable type filters should be
replaced. Reusable type filters may be cleaned.
You may want to ask your dealer about high efficiency filters. High efficiency filters are available in both electronic and non-
electronic types. These filters can do a better job of catching small airborne particles.
Compressor
The compressor motor is hermetically sealed and does not require additional oiling.
Motors
Indoor and outdoor fan motors are permanently lubricated and do not require additional oiling.
Clean Outside Coil (Qualified Servicer Only)
Air must be able to flow through the outdoor unit of your com-
fort system. Do not construct a fence near the unit or build a
deck or patio over the unit without first discussing your plans
with your dealer or other qualified servicer. Restricted airflow
could lead to poor operation and/or severe equipment damage.
Likewise, it is important to keep the outdoor coil clean. Dirt,
leaves, or debris could also restrict the airflow. If cleaning of
the outdoor coil becomes necessary, hire a qualified servicer.
Inexperienced people could easily puncture the tubing in the coil. Even a small hole in the tubing could eventually cause a large
loss of refrigerant. Loss of refrigerant can cause poor operation and/or severe equipment damage.
Do not use a condensing unit cover to “protect” the outdoor unit during the winter, unless you first discuss it with your dealer.
Any cover used must include “breathable” fabric to avoid moisture buildup.
Before Calling Your Servicer
Check the thermostat to confirm that it is properly set.
Wait 15 minutes. Some devices in the outdoor unit or in programmable thermostats will prevent compressor operation for
awhile, and then reset automatically. Also, some power companies will install devices which shut off air conditioners for
several minutes on hot days. If you wait several minutes, the unit may begin operation on its own.
Check the electrical panel for tripped circuit breakers
or failed fuses. Reset the circuit breakers or replace fuses
as necessary.
Check the disconnect switch near the indoor furnace or
blower to confirm that it is closed.
Check for obstructions on the outdoor unit . Confirm that
it has not been covered on the sides or the top. Remove
any obstruction that can be safely removed. If the unit
is covered with dirt or debris, call a qualified servicer to
clean it.
Check for blockage of the indoor air inlets and outlets.
Confirm that they are open and have not been blocked
by objects (rugs, curtains or furniture).
Check the filter. If it is dirty, clean or replace it.
Listen for any unusual noise(s), other than normal operating noise, that might be coming from the outdoor unit. If you
hear unusual noise(s) coming from the unit, call a qualified servicer.
T
O
AVOID
THE
RISK
OF
EQUIPMENT
DAMAGE
OR
FIRE
,
INSTALL
THE
SAME
AMPERAGE
BREAKER
OR
FUSE
AS
YOU
ARE
REPLACING
. I
F
THE
CIRCUIT
BREAKER
OR
FUSE
SHOULD
OPEN
AGAIN
WITHIN
THIRTY
DAYS
,
CONTACT
A
QUALIFIED
SERVICER
TO
CORRECT
THE
PROBLEM
.
I
F
YOU
REPEATEDLY
RESET
THE
BREAKER
OR
REPLACE
THE
FUSE
WITHOUT
HAVING
THE
PROBLEM
CORRECTED
,
YOU
RUN
THE
RISK
OF
SEVERE
EQUIPMENT
DAMAGE
.